Product Specification
Page 3 of 18
1303090MS01
LA-309 Controlled Atmosphere Infrared Furnace
April 15, 2009
1.0 SCOPE
This document lists and defines the specifications, requirements and acceptance criteria for controlled
atmosphere continuous belt infrared furnace equipment. The equipment shall be configured as follows
(see section 15.0 for definitions of terms).
Table 1-1. Equipment Model
Model
Base Equipment
IR Heated Length
Nominal Belt With
LA-309
Continuous Belt Controlled
Atmosphere Furnace
30 in (76 cm),
3 Zones
9 in (23 cm)
2.0 EQUIPMENT
ARRANGEMENT
The equipment arrangement shall be as shown in Drawing 803-091734 FURNACE
ARRANGEMENT and as described herein.
Table 2-1. Equipment Arrangement
Phase
Process
Process Gas
Temperature (typ)
Phase 1
30 in (76 cm) IR Furnace, 3 Zones
N
2
400°C
Phase 2
30 in (76 cm) Closed Atmosphere Cooling Tunnel
N
2
Below 150°C
3.0
BASE EQUIPMENT FEATURES & OPTIONS
3.1
The maximum design temperature of the furnace shall be 500°C (or 1000°C with HT option).
3.2
The furnace shall be constructed so that control of in-process atmosphere can be maintained in
all Phases.
3.3
BASE EQUIPMENT.
The base furnace equipment shall be designed with the following
standard and special features (see proposal Base Furnace Equipment List for included features,
see section 0 for a description of all available features):
Equipment operation shall be from left to right as viewed from the operator
console.
Std
Hermetic Chamber including Plenums for Nitrogen
Yes
Nitrogen process gas: Accepts Nitrogen process gas
Yes
Product Size: 9 inch (23 cm) wide belt, 2 inch (50 cm) high furnace opening
Std
3.4
OPTIONS.
The system may be configured with the following optional equipment (see
proposal for priced options, see section 17.0 for a description of all available options):
DSC (three-phase safety disconnect)
Opt
EH (edge heaters for fine tune control of temperature across belt width)
Opt
1000ºC max operation
Opt
3-color process ready light tower
Opt
IPS (N
2
inlet pressure switch)
Opt
76 mm diameter entrance interface roller
Opt
76 mm diameter exit interface roller
Opt
Upstream-downstream handshake
Opt
Nitrogen auto shutdown with delay
Opt
Oxygen analyzer (use with
3-point sampling system)
Opt
3-point sampling system (for use with
and
) Opt
Lamp element monitoring system (detects lamp failures)
Opt
4 inch high max product clearance
Opt
3.5
Base offering includes factory assembly and testing in Orange, California USA; installation
checkout and startup commissioning at the owner’s site in Italy.
Summary of Contents for LA-309
Page 5: ...10 004 676 110000 v WARRANTY Warranty goes here ...
Page 6: ...vi LA 309 Owner s Manual ...
Page 12: ...Contents xii LA 309 Owner s Manual ...
Page 20: ...Section 1 1 8 LA 309 Owner s Manual ...
Page 68: ...Section 3 3 28 LA 309 Owner s Manual ...
Page 70: ...Section 4 4 2 LA 309 Owner s Manual ...
Page 72: ...Section 4 4 4 LA 309 Owner s Manual ...
Page 98: ...Section 5 5 2 LA 309 Owner s Manual ...
Page 100: ...Section 5 5 4 LA 309 Owner s Manual ...
Page 106: ...Section 5 5 10 LA 309 Owner s Manual ...
Page 108: ...Section 5 5 12 LA 309 Owner s Manual ...
Page 110: ...Section 5 5 14 LA 309 Owner s Manual ...
Page 112: ...Section 6 6 2 LA 309 Owner s Manual ...
Page 114: ......
Page 115: ......
Page 126: ...Section 7 1 Fiberfrax Cements MSDS 042006 Owner s Manual ...
Page 139: ...MSDS 2 Fiberfrax Duraboard MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 140: ...Section 7 2 Fiberfrax Duraboard MSDS 042006 Owner s Manual ...
Page 153: ...MSDS 3 Fiberfrax Fibers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 154: ...Section 7 3 Fiberfrax Fibers MSDS 042006 Owner s Manual ...
Page 167: ...MSDS 4 Fiberfrax Papers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 168: ...Section 7 4 Fiberfrax Papers MSDS 042006 Owner s Manual ...
Page 181: ...MSDS 5 Magnaform MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 182: ...Section 7 5 Magnaform MSDS 050406 Owner s Manual ...
Page 183: ......
Page 184: ......
Page 185: ...Section 7 6 RTU Silicone Red Hi Temp 042006 Owner s Manual ...
Page 186: ...MSDS 6 RTU Silicone Red Hi Temp 042006 MATERIAL SAFETY DATA SHEETS ...
Page 189: ...Section 7 7 Kaowool Insulation MSDS 050406 Owner s Manual ...
Page 190: ...MSDS 7 Kaowool Insulation MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 201: ...Material Safety Data Sheets 7 15 Notes ...
Page 202: ...Section 7 7 16 Owner s Manual ...
Page 204: ...Section 8 Owner s Manual ...
Page 206: ...Section 8 Owner s Manual ...
Page 212: ...iv Operation and Troubleshooting ...
Page 214: ...vi Operation and Troubleshooting ...
Page 224: ...Page 10 Operation and Troubleshooting ...
Page 231: ...9 1 Section 9 APPENDIX B 9 1 EC913 CALIBRATION REPORT 9 2 SERIES EC900 OXYGEN ANALYZERS ...
Page 232: ...Section 8 Owner s Manual ...
Page 233: ......
Page 234: ...Section 8 Owner s Manual ...
Page 279: ...Section 8 Owner s Manual ...
Page 281: ...MSDS MATERIAL SAFETY DATA SHEETS ...
Page 282: ...16 Notes ...