background image

SPR-16

E i

 O

wnEr

s

 M

anuaL

Connection

AC Cable Routing

Once the SPR-16E i is placed in your system, its AC cord’s female end must be plugged into the male IEC connector located on 
the lower left hand side of the rear panel (when facing the rear panel).  Next the male plug must be connected to an appropriate 
socket (see current rating recommendation above).  

Connecting Components to  the “Linearly Filtered Outlets - Video” Bank

The SPR-16E i’s four “Linearly Filtered Outlets - Video” should be employed for critical video components such as DVD players, 
projectors, Plasma, or LCD video screens.  When employing the SPR-16E i for a 2-channel audio system, a pre-amplifier and or CD 
player would be ideally suited for these outlets.  

Connecting Components to the “Linearly Filtered Outlets - Audio” Bank

The SPR-16E i’s four  “Linear Filtering Outlets - Audio” should be employed for any critical  audio components such as a CD or 
SACD player, turntable, or digital media reciever.  These outlets still possess incredible AC noise filtering to maximize system 
performance.

Connecting Components to the “High Current - Linear Filtered Outlet” Banks

The SPR-16E i’s high current (16A) outlet possesses the same Linear Filtering Technology as the other 11 outlets, but it can 
supply 16 amps. This higher current IEC outlet is appropriate for ultra-high current amplifiers requiring more than a 10 amp tap 
(very rare) or for series connection to the Furman IT-Reference 16E i. The bank’s three 10A “Linear Filtering Outlets” should be 
employed for any components not connected to the Linearly Filtered Video or Linearly Filtered Audio outlet banks.

Rear Panel / Suggested AC Connection

Soft Start - Continuous Use and Break-In Time

When power is first applied to the SPR-16E i, (the front panel breaker- power toggle must be switched to the “on” position) the 
Soft Start feature is activated.  There is an audible “clack” when the SPR-16E i is first turned on or off.  This sound is produced 
by the Soft Start circuit’s 30 Amp relay engaging or disengaging.  There is virtually nothing in the SPR-16E i’s construction, 
design, or componentry to wear over the life time of the product, and there is no power draw from your electric service meter 
aside from the LED indicators, volt/current meter, and relay circuits.  For this reason the SPR-16E i may be left with its power 
engaged permanently at a cost of pennies per month. This is an added benefit, as many audio/videophiles find performance 
improves significantly when leaving low-powered components permanently charged (turned on).  In fact, this is true of the 
SPR-16E i.  Though it will function flawlessly right from its shipping carton, the performance of its circuit parts will improve after 
approximately two weeks of continuous use or “break-in.”  

AC Cord 

Inlet

Front Panel

Voltmeter/Current 

Meter Dimmer

Cable/Satellite

Connectors

(x4 pairs)

10A Circuit Breaker  

(High Current Linear 

Filtered Outlets)

2 - 7 Channel

Amplifier

High-Current 

Power Amplifier 

 or Furman  

IT-Reference 16E i

VCR/DVR

DVD/ HD-DVD/

Blu-Ray Player

LCD/Plasma  Monitor

or Video Projector 

Cable/Satellite

Receiver

CD Player

Turntable

10A Circuit 
Breaker (Linear 
Filtered Outlets)

Powered

Subwoofer

Summary of Contents for SPR-16E i

Page 1: ...OWER VOLTAGE REGULATOR POWER CONDITIONER CONDITIONNEUR D ALIMENTATION ET R GULATEUR DE TENSION STABLE ESTABLE REGULADOR DE VOLTAJE ACONDICIONADOR DE POTENCIA OWNER S MANUAL GUIDE DE L UTILISATEUR MANU...

Page 2: ......

Page 3: ...16E i Guide De L Utilisateur SPR 16E i Owner s Manual All content 2007 Furman Sound LLC All Rights Reserved Printed in China ENGLISH Page 4 FRAN AIS Page 10 ESPA OL Page 18 SPR 16E i Manual Del Propie...

Page 4: ...their full potential With the SPR 16E i home theaters are supplied with constant virtually unwavering AC voltage This assures trouble free service for any environment suffering from unstable power The...

Page 5: ...e SPR 16E i does not appear to operate normally or exhibits a marked change in performance The SPR 16E i has been dropped or the enclosure damaged The SPR 16E i requires that a safety ground be presen...

Page 6: ...Outlets should be employed for any components not connected to the Linearly Filtered Video or Linearly Filtered Audio outlet banks Rear Panel Suggested AC Connection Soft Start Continuous Use and Brea...

Page 7: ...ion for cable or satellite lines utilizing standard coaxial connectors As these surge suppressors are in line they will require an additional cable to connect from their output to the control device r...

Page 8: ...an determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or Furman determines that the connected equipment was not used under normal operating conditio...

Page 9: ...z 80 dB from 100Khz 1GHz Linear attenuation curve from 0 05 100 ohms line impedance Outlets 1 linearly filtered outlet 16 amp 7 linearly filtered outlets 4 linearly filtered outlet with additional ult...

Page 10: ...prolonger son utilisation et de r pondre aux demandes suppl mentaires Cette situation affecte consid rablement le rendement de votre syst me Les amplificateurs de puissance et les caissons d extr mes...

Page 11: ...xp dition Vous en aurez besoin dans l ventualit d un retour de l unit l usine aux fins de r paration La bo te devrait contenir l unit SPR 16E i un cordon c a amovible un ensemble de montage en b ti un...

Page 12: ...en retirant les deux 2 vis t te frais e plate situ es dans les coins avant du panneau sup rieur L installation de chaque querre de montage exige trois 3 vis Philips t te cylindrique bomb e incluses d...

Page 13: ...d une source de 208 ou 240 V c a cette situation survient fr quemment lorsque la prise c a source n est pas une ligne d di e et qu elle a plut t t reli e un fil neutre connect en s rie partir d une b...

Page 14: ...s de c blodistribution et lignes de signaux num riques par satellite comme nous l avons fait pour la section de 230 V c a Cela n cessiterait une largeur de bande r duite ne permettant pas la transmiss...

Page 15: ...normales d utilisation ou selon les instructions propos es par le Fabricant de l quipement connect Tous les limiteurs de surtension de Furman doivent tre reli s directement une ligne d alimentation c...

Page 16: ...att nuation lin aire avec imp dance de ligne de 0 05 100 ohms Prises 1 prises avec technologie de filtrage lin aire 16A 7 prises avec technologie de filtrage lin aire 4 prises avec technologie de filt...

Page 17: ...17...

Page 18: ...taje del SPR 16E i los amplificadores y los sub woofers muestran su capacidad al m ximo Con el SPR 16E i los teatros en casa son previstos con un constate en la CA Esto asegura el servicio sin problem...

Page 19: ...a expuesto a la lluvia o humedad S el SPR 16E i no parece funcionar normalmente o expuesto a un cambio marcado en su funcionamiento Si el SPR 16E i se ha ca do o da ado El SPR 16E i requiere de una co...

Page 20: ...a de primer SPR 16E i la palanca de la energ a del triturador del panel delantero se debe cambiar a on la caracter stica del suave comienzo estar activado Cuando el SPR 16E i se ha encendido o apagado...

Page 21: ...tener la unidad de nuevo encendido sin haber comprobado la fuente del problema y quiz s cambiar la fuente de AC Sat lite Supresor de Voltaje El SPR 16E i para las l neas del cable o del sat lite que u...

Page 22: ...les o de acuerdo con las instrucciones del fabricante para conectar el equipo Todos los protectores Furman se deben conectar correcta y directamente en una l nea de energ a de CA No se permite dos o t...

Page 23: ...s de l nea impedancia Enchufes 1 enchufes lineales 16A 7 enchufes lineales 4 enchufes lineales con filtro ultras nico para componentes digitales o de video Supresi n transitoria de la oleada del volta...

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 707 763 1010 Fax 707 763 1310 www FurmanSound com SPR16EiM_Rev1a...