aR-15 II Voltage RegulatoR / poweR condItIoneR

be completely disconnected from all power 
and removed from its rack. the six hex head 
screws and two phillips head screws holding 
the top cover must be removed. the internal 
fuse is located in a holder on the printed circuit 
board. Replace the fuse only with the exact 
same type (1/4 fast blow).

Input Voltage monItoRIng

the row of ten Led’s at the left of the front 
panel make up a meter that indicates input 
VoLtAge. only one Led will light up at a time. 
there are is one red Led at each endpoint. 
when lit, they indicate that the input voltage 
may be above or below the point where it can 
be restored to the selected nominal output volt-
age (though it may still be restored to a usable 
level) but is not high or low enough to cause an 
extreme voltage shutdown.

Voltage monItoRIng

A green Led labelled in ReguLAtion indicates 
proper function (i.e., that the output voltage is 
within ±5V of the selected output voltage). Your 
equipment will always work normally when this 
light is on, and often will work satisfactorily even 
when it is off. 

InstallatIon

Because of their toroidal transformer design, 
Furman Voltage Regulators may be posi-
tioned near most other equipment without fear 
that the other equipment will be disrupted by 

leakage of a strong 50/60 Hz magnetic field. 

nevertheless, suggested rack locations would 
be either at the top or bottom. 

As with any rackmount equipment, be sure to 
use 10-32 machine screws for mounting in the 
rack’s tapped holes (this is not a metric size). 

in particular, beware of 10-24 screws, which 

may fit if forced but which will strip the threads. 
To avoid marring the front panel finish, use 

plastic washers under the screw heads.

desIgn

the AR-series uses a design based on an 
eight-tap toroidal autoformer. the toroidal de-
sign assures minimal leakage of stray magnetic 

fields, and, because of its high efficiency, a very 

compact size for its rating. the Voltage Regula-
tor’s circuitry monitors the incoming line voltage 
with each cycle, comparing it to an extremely 
precise voltage reference, accurate to ±0.15%. 

If a voltage fluctuation requires that a different 

tap be selected, the new tap is electronically 
switched exactly at the zero-crossing, to avoid 
distorting the AC waveform. if necessary, it can 
switch taps as often as once each cycle. Most 
commercial voltage regulators using multiple-
tapped transformers switch taps at uncontrolled 
times, thereby creating voltage spikes and 
clicks that can leak into the audio! Hysteresis in 

the switching circuits avoids “chatter” or unnec

-

essary switching back and forth between adja

-

cent taps. unlike those voltage regulators that 
employ ferro-resonant transformers, Furman 
Voltage Regulators are not sensitive to small 
errors in line frequency, making them ideal for 
use with generators.

maxImum and mInImum load

the AR-15 ii can handle loads totalling up to 
15 amperes as long as the input voltage is 
equal to or above 124 volts. For voltages below 
that level, its capacity must be derated at ap-
proximately 113 milliamperes per volt. (see 
graphs on back page.) As a practical matter, 
therefore, to cope successfully with worst-case 

4

Summary of Contents for elite AR-15

Page 1: ...AC Line Voltage Regulator and power conditioner AR 15 II Voltage Regulators...

Page 2: ...to read this manual carefully WARNING To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the...

Page 3: ...vels depending on the requirements of the equipment This stable voltage protects equipment and allows optimal performance See graphs on the back page The AR 15 II has eight outlets on the rear panel a...

Page 4: ...ains power is above the high cutoff voltage and has caused the unit to remove power from its outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turn...

Page 5: ...the rack s tapped holes this is not a metric size In particular beware of 10 24 screws which may fit if forced but which will strip the threads To avoid marring the front panel finish use plastic was...

Page 6: ...nd de grade wiring insulation They are an unavoid able component of electric power They are caused unpredictably by electric motors switch ing on or off on the premises or outside utility company main...

Page 7: ...defects in products or components not manufactured by Manufac turer or against damages resulting from such non Manufacturer made products or compo nents This warranty shall be cancelable by Manufactur...

Page 8: ...s protected by a limited three year warranty covering defects in materials and workmanship Furman Sound LLC 1690 Corporate Circle Petaluma CA 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www...

Reviews: