background image

ElitE 10 E ownEr’s manual

faults – for example, accidental connection 
to an open neutral (in some countries) could 
put well over 300 VAC RMS onto the mains 
outlet.  The Series Multi-Stage Protection 
Plus (SMP+) circuit senses voltages that are 
so high that operation would be impossible 
and shuts the power down before damage 
can occur. Upon initially applying power to 
these units, the Extreme Voltage indicator 
LED will light if the input voltage is above the 
extreme voltage cutoff, and power will not be 
applied to the unit’s outlets. If the unit has been 
operating with an acceptable input voltage 
and subsequently that voltage exceeds 270 

VAC, it will shut off power to the outlet and the 

Extreme Voltage LED will light.   

Protection oK indicator:

Although the Furman SMP circuit assures 
virtually maintenance free protection from 

transient voltage spikes and surges, nature 
has a way of occasionally creating electrical 
forces that are beyond the capabilities of any 

Transient Voltage Surge Suppression device 

to absorb without some degree of damage. 
In the rare instance that this occurs, the blue 
LED located in the center of the front panel 
will dim, even though AC power is present at 
the unit’s outputs. If this happens, some level 
of protection from voltage surges will remain, 
but the Furman’s clamping voltage rating will 
be compromised. The unit must be returned 
to Furman Sound, or an authorized Furman 
Service center for repair. 

NOTE: If the mains power is above the high 
cutoff voltage and has caused the unit to 

remove power from its outlets, it cannot restore 
power without the operator manually turning 
the unit off, then on again. Avoid turning the 
unit back on, without first checking the source 

of the problem, and perhaps changing the AC 
source.

         

satellite – Cable transient Voltage surge 
suppressors 

The Elite-10 E features transient voltage surge 

suppression for both cable and or satellite lines 
utilizing standard coaxial connectors. As these 
surge suppressors are in-line, they will require 
an additional cable to connect from their output 
to the control device requiring protection.

All in-line surge suppressors feature 

our exclusive ground contamination free 
technology. This aids in eliminating audio 
buzzing, and the video hum-bars that can 
result from typical in-line suppressors. Further, 
our cable and satellite suppressors are TIVO 
friendly as well as HD-Digital Television 
ready.  Both DC carrier signals as well as high 
bandwidth signals can pass through our circuit.  

In fact the bandwidth is less than 0.1dB loss at 

1GHz!

To connect your cabling to these in-line 

protectors, simply follow the in and out 
indications marked next to the Cable and 

Satellite connectors.

NOTE: It is not possible to make an in-line cable 

or satellite protector “maintenance-free” as we 
have accomplished with the 230 VAC line.  This 
would necessitate limited signal bandwidth that 
would not allow the signal to pass. Under extreme 
conditions, it is possible that the surge suppression 
in one of these devices could sacrifice itself after a 
catastrophic event. If the cable or satellite connector 
becomes deformed in any way due to an extreme 
lightning strike, please contact your local service 
representative, installer or Furman Authorized 
service center.  

 

4

Summary of Contents for Elite 10 E

Page 1: ...Elite 10 E owner s manual...

Page 2: ...true of today s home theater Our solution based technology extensive engineering expertise and robust build quality have answered the challenge of today s corrupted power lines and led to the creation...

Page 3: ...ter Fill out and return your warranty registration card Registration is recommended because it can be used to establish whether the unit is within the warranty period should your original ownership do...

Page 4: ...0 E for a 2 channel audio system an SACD player would be ideally suited for one of these outlets Connecting Components to the Linear Filtered Audio Component AC Outlet Banks The Elite 10 E s four Line...

Page 5: ...power from its outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turning the unit back on without first checking the source of the problem and perh...

Page 6: ...le for inspection until the claim is finalized The Connected Equipment Warranty is also in effect for a period of three years unless the Purchaser does not complete the warranty registration within fi...

Page 7: ...ives ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES shall not be relied upon by purchaser and are not a part of the contract for sale or this limited warranty This Limited Warranty stat...

Page 8: ...76V peak clamping 6000V 3000A input Extreme Voltage Shutdown 275 VAC Cable Satellite less than 1dB insertion loss Power Consumption 2 Watts for display and control circuits independent of actual load...

Reviews: