11
Input Voltage
Frequency
Open Circuit
Voltage
Output
Current
Range
220V
Output
Current
Range
110V
Duty Cycle at
40°*
110V / 220V
–
1ph
(+/- 10%)
50/60 Hz
75V
20
–
250A
20-140 A
40%
Min. recommended
fuse
Output current
type
Insulation class
IP
Weight
30A
DC
I.CL.H
IP 21 S
5.5 Kg
PRODUCT DETAIL
4.
Details
Voltage 110/220V 50/60Hz.
DC output current, recommended for 6013, 7018 5
/32” electrodes.
TIG LIFT ARC
ARC FORCE, HOT START and MMA.
DIGITAL DISPLAY.
250A DC.
60% duty cycle at 40°C*.
Duty cycle
Duty cycle is the percentage of time that the welding machine can deliver continuous welding
current, in a period of 10 minutes. In the Furius FIX 251 this value is 40% when the output current is
set at the maximum and the ambient temperature is 40 ° C. This percentage increases as the set
output current decreases and / or the ambient temperature decreases.
This means that the machine can deliver its maximum output continuously for 6 minutes, and after
this period the
thermal control device
will be activated, and the user must let the machine rest (it
should be left turned on) at least for 4 minutes. After this period, you can resume work normally.
The duty cycle may decrease if the ambient temperature rises above 40 ° C.
Warning!
Do not exceed the
duty cycles established on the
tech plate included in the
welder and in this instruction.
Summary of Contents for FIX 251
Page 1: ...1 www furiustools com Manual de instrucciones FURIUS FIX 251 FW215 FW285...
Page 12: ...12 5 FICHA T CNICA...
Page 23: ...23 14 REFACCIONES...
Page 25: ...1 www furiustools com FURIUS FIX 251 Instruction Manual...
Page 36: ...12 5 TECH PLATE...
Page 46: ...22 14 SPARE PARTS...