7
.
Technology
Specification
6
.
Problems
and
Solutions
Problem
Cause Analysis
Solution
Green power
indicator does
not work
Press
“self-test/mute”
button but
no response
No response
to target gas
Keep alarming
after warm-up
Connectivity of
power supply
Power indicator breaks
Circuit breaks
Warm-up
does not finish
Circuit breaks
Work environment
filled with organics
like smoke,
alcohol steam,
fume, perfume
and so on
The storage period
is too long
Circuit breaks
Check the
connectivity
Call customer service
Call customer service
Wait till
warm-up finishes
Call customer service
Move the device
to clean air the test
if it work normally
Supply power to age
for over 2 hours
Call customer service
Model
Detecting Gas
Working Environment
Sampling Method
Testing Range
Alarm Presetting Level
Warm-up Time
Sensor Type
Life Span
Working Voltage
Weight
Dimension
Alarm Method
Alarm Sound
5 Yeas
(
Under normal working environment
)
5
±
0
.
1V
71g
86mmXH29mm
Visual, audible signals alarm
≥70dB
Temperature: 0 ~ 40 degree Celsius
Humidity: <95%RH (No Frost)
FTH-KBF1
Natural gas ( CH4, Methane)
Natural diffusion
0~100% LEL
7% LEL
180
Semiconductor
8
.
After-sales policy and warranty policy
THIS PRODUCT SUPPORTS ONE-YEAR FREE REPLACEMENT, BUT IF NON-
NORMAL USE DOES NOT ENJOY THE WARRANTY (FOR EXAMPLE:
LIGHTNING, VOLTAGE INSTABILITY, WATER AND OTHER MAN-MADE) .
Matters needing attention
1
)
It is not suitable to be installed too close to the stove.
2
)
It is not suitable to be installed in the place where the
smoke is too large.
3
)
It is not suitable to be installed in the exhaust fan,
doors and windows, bathroom and other water vapor, gas.
Where the flow is larger.
1. Please start a self check button every 6 months to
ensure the working condition of the equipment
is
normal .
2. Please use soft brush and dry flannel to clean the
surface dust and oil to ensure good air permeability and
good indication. Do not use cleaning agent, bleach powder
or polish when cleaning.
3. This product is designed for indoor use only. Please
avoid equipment contact with rain or wet gas. At the same
time, avoid falling equipment, do not knock, open or
change equipment, otherwise it may cause product failure.
4. Under normal use, the maximum useful life of the
equipment is 5 years. New equipment should be replaced
over the period of use.
5.
Equipment Maintenance