![Funkwerk P/N 800ATC-A-(201)-(301) Operation And Installation Download Page 18](http://html1.mh-extra.com/html/funkwerk/p-n-800atc-a-201-301/p-n-800atc-a-201-301_operation-and-installation_2346521018.webp)
TRT800A / P/N 800ATC-A-(201)-(301)
Operation and Installation
18
Document-No: 03.2112.010.71e / Revision: 1.02
3.6.1.2 Ground Switch
If a Ground-Switch is connected (and activated in the Setup), the
transponder is enabled to distinguish between On-Ground and In-Flight
Condition. In On-Ground Condition the transponder automatically enters
the Standby mode.
In order to activate this function the input „FLY-GND“ must be connected
to a switch, which connects the input with „GND“ in case the gear is
weighted, or remains open in the other case.
This option must additionally be activated in the Setup. For details on
configuration please refer to section 4.2.1.
3.6.2
Static Air Port
Install a silicon soft tube fitting the 5 mm static air port at the backside of
the transponder and secure plumbing with appropriate clamps.