- 18 -
mbos2a2 (06.09.2012)
Kompetent für Elektroniksysteme
mbos2a2 (06.09.2012)
- 19 -
Kompetent für Elektroniksysteme
Jumpers (Junction Box MBOS2AB1)
The polarity of PTT keying can be configured separately for every radio using jumpers JP1 to JP4
(position "1" (as in the scheme below) = +batt; position "2" = GND).
Jumper
Function
Pos. 1
Pos. 2
JP1
PTT keying of circuit 1 to
+Batt
GND
JP2
PTT keying of circuit 2 to
+Batt
GND
JP3
PTT keying of circuit 3 to
+Batt
GND
JP4
PTT keying of circuit 4 to
+Batt
GND
Board Layout (Junction Box MBOS2AB1)
The connection cable MBOS2Kx for the control set (Major) is connected to socket ST1. The radios
FuG1 to FuG4 can be connected via terminal strips ST3 to ST6.
1
8
FuG 3
FuG 1
8
1
1
8
FuG 4
FuG 2
8
1
TR4
TR3
TR1
1
JP4
1
JP3
1
JP1
R13
R14
R15
R16
R12
R11
R9
R10
R2
R1
R6
R5
R3
R4
R7
+
C4
+
C3
+
C1
1
ST5
1
ST6
1
ST4
D2
D1
D3
1
17
32
16
ST1
TR2
1
JP2
R8
+
C2
1
ST3
D4