8-1
FL11.3TR
TROUBLESHOOTING
[ Power Supply Section ]
The power cannot be turned on.
The fuse blows out.
FLOW CHART NO.1
FLOW CHART NO.2
Is normal state restored when once unplugged power
cord is plugged again several seconds?
Check if there is any leak or short-circuiting on the
primary circuit component, and service it if defective.
(C605, C606, D601, D602, D603, D604, Q601,
Q602, T601)
Yes
No
Yes
Is the fuse (F601) normal?
See FLOW CHART No.2 <The fuse blows out.>
No
Yes
Is the INV+35V line voltage normal?
No
Check each rectifying circuit of the secondary circuit
and service it if defective.
Check the presence that the primary component is
leaking or shorted and service it if defective.
Check the presence that the rectifying diode or circuit
is shorted in each rectifying circuit of secondary side,
and service it if defective.
After servicing, replace the fuse.
When the output voltage fluctuates.
FLOW CHART NO.3
Does the photocoupler circuit on the secondary side
operate normally?
No
Yes
Check IC601, D652, Q631 and their periphery
circuit, and service it if defective.
When buzz sound can be heard in the vicinity of power circuit.
FLOW CHART NO.4
Check if there is any short-circuit on the rectifying diode and the circuit in each rectifying circuit of the secondary side,
and service it if defective. (IC631, Q209, Q210, Q211, Q213, Q635, Q636, Q637, Q640, Q641, Q642, Q643,
D631, D632, D633, D634, D636, D638, D641, D642, D646, D647)
Check if there is any leak or short-circuit onthe loaded
circuit, and service it if defective.
INV+35V is not output.
FLOW CHART NO.5
Is approxi32V voltage supplied to the cathode
of D636?
No
Yes
Check C638, D634, D636, D639 and their periphery
circuit, and service it if defective.
Check IC601, D609, D611 and their periphery,
circuit and service it if defective.