- 9 -
11. Disposal
Old electrical appliances are recyclable. Do not dispose them in the domestic waste! Separately deliver
these in a valuable material collection point. Dispose the packing material environmental friendly. Please
give cardboard and paper to te waste paper, foils to a valuable material collection point.
12. ESPECIFICATION
13. WARRANTY AND SERVICE AGREEMENTS
This warranty covers only manufacturing defects. The appliance must not be modified or altered in any way with
regards to both form and function. This warranty does not apply in case of improper usage that falls beyond
normal use as indicated in the user’s manual or if there is damage caused by force majeure (e.g. natural
disaster). Only clean and intact appliances will be accepted for warranty and non-warranty repair. Tje standard
warranty period is covered as legally terms settled starting from the purchase date. In order to make a warranty
claim, this warranty card must be submitted along with proof of purhcase, including the model number,
purchase date and a dealer’s stamp.
Model number: ...............................................................
Purchase date: ................................................................
Dealer’s stamp and signature: ........................................
Date of warranty claim: ...................................................
Defect(s) noted: ..............................................................
14. ICON INDICATION
MODEL
PDA-600SS-C
PDA-1000SS-C
PDA-1500SS-C
PDA-2000SS-C
Output
Rated power
600W
1000W
1500W
2000W
Surge power
1200W
2000W
3000W
4000W
AC output
220±10% 50Hz or 110V ± 10% 60Hz (refers to product’s label)
Wave form
Pure sine wave
USB port
5V 2.1A (optional)
Input
DC input
12V (10-15V) or 24V 21-30V)
AC input range
170-250V (220V) or 70-150V (110V)
Charger
Max. Current
12V
10A
15A
24V
5A
7A
Charge way
Constant current, constant voltage, floating charge (Auto.3 Stage)
Transfer time
<15ms
<25ms
Protection
function
Overload
630-700W
1100-1200W
1600-1700W
2100-2200W
Over temperature
>60ºC auto.shutdown
Other
earth leakage, polarity reverse,over voltage, low voltage, overload,
overheat, short circuit
AVS protection