background image

w w w . f u l l w a t . c o m

LP803450-CI

 

 

Polymer Lithium-ion battery

  5. Safety test 

Test conditions:

 The following tests must be measured air and safety protection conditions. All batteries must 

standard charge and lay 24h.

 

Item

Test methods

Performance

Over charge 

At 20±5°C, charging batteries with constant current 3C

5

A to voltage 

5V then with constant voltage 5V till current decline to 0. Stop test 
till batteries temperature 10°C lower than max temperature. 

No explosion 
or fire

Over 
discharge

At 20±5°C, discharge battery with 0.2C

5

A continuously 12.5h. 

No explosion 
or fire

Short circuit

At 20±5°C, connect batteries anode and cathode by wire which 
impedance less than 50m Ω, keep 6h.  

No explosion 
or fire

Extrusion

20±5°C, put the battery in two parallel steal broad, add pressure 
13kN. 

No explosion 
or fire

Thermal 
shock

Put the battery in the oven. The temperature of the ovenis to be 
raised at 5±1°C per minute to a  temperature of 130±2°C and 
remains 60 minutes.

No explosion 
or fire

  6. Schematic battery

53.5±1

120±1

34±0.5

7.8±0.5

LP603450-CI

--DD

PP

 

Voltaje: 3,7 Voltios  Capacidad: 1050 mA

h

Li-P

o

NTC

P

C

M

+

- -

+

JST connector 

PAP-03V-S

units: 