Full Gauge Controls TO-711F Quick Start Manual Download Page 3

Timer trigger mode

Defines the timer triggering mode:
 

[MAN]

=

 

 Manual, through the 

$

key.

 

[INI]

=  Start  up,  when  the  controller  is 

powered up.
 

[TMP]

=Temperature,  when  the  oven 

working temperature is reached.

Note:

 In modes 

[INI]

 and 

[TMP]

 the

$

 

key only cancels the timer.

[F12]

MAN TMP

-

MAN

Timer counting direction

Defines the direction the timer counts:

[DEC]

 = time count down;

[CRE]

 = time count up;

[F13]

DEC CRE

-

DEC

Timer time base

Defines the time base of the timer:

[MM:SS]

=  minutes,  maximum  time 

99:59 minutes;

[HH:MM]

 = hours, maximum timer 99:59 

hours.

[F14]

HH:MM

HH:MM

-

-

MM:SS

MM:SS

MM:SS

MM:SS

Timer reset mode

Defines the timer reset mode, essentially 
wheter the audible alarm will be switched 
off manually or by time:
 

[MAN]

=Manually through the

$

key;

 

[AUT]

=Automatically  according  to  the 

time defined in parameter F17;

Note:

 The timer also resets when the door 

of the oven is opened, independently of the 
mode defined in this parameter.

[F15]

MAN AUT

-

MAN

Timer reset time base

Defines  the  time  base  when  the  timer  is 
reset:

[MM:SS]

= minutes, maximum time 99:59 

minutes;

[HH:MM]

=  hours,  maximum  time  99:59 

hours.

[F16]

Time  to  reset  the  timer 
(aut mode)

Defines  the  time  to  reset  the  timer  if 
automatic  reset  is  selected  in  parameter 
F15

[F17]

0:01 99:59 F16 0:05

MIN

MIN

MAX

MAX

UNIT

UNIT

DEFAU

DEFA

DESCRIPTION

DESCRIPTION

FUN

FUN

FUNCTION

FUNCTION

Steam working mode

Defines the steam operating mode for the 
selected preset 

[rCnF]

:

 

[OFF,]

Off: does not inject steam. 

 

[MAN,]

M

 

anual:

 

injects  steam  when  the 

%

key is pressed. 

[AUT,] 

Automatic:   automatically injects 

steam  after  the  timer  is  activated.  The 
steam is activated after the time set in F19 
has elapsed.

[CYC,]

Cyclic:  injects  steam  in  cycles 

using the times configured in 

[UAon]

 and 

[Uaof]

.

Note: 

When the preset mode is active, this 

configuration is made in menu 

[rUa,]

.

[F18]

OFF CYC

-

MAN

Delay  to  activate  the 
automatic steam

Defines  the  delay  before  injecting  steam 
into  the  oven  after  the  timer  is  activated. 
This  parameter  is  valid  when  automatic 
steam is adjusted in parameter F18.

[f19]

1

180

sec.

5

Time  interval  between 
steam activations

Defines the minimum time interval between 
steam  activations,  i.e.  once  the  steam 
output  is  activated,  the  controller  will  not 
activate it again before the time adjusted in 
this parameter has elapsed. To disable this 
function,  change  the  adjustment  to  the 
minimum until 

[no,]

is displayed.

Note:

 This parameter is disregarded when 

the type of steam selected is cyclic.

[f20]

no(0) 30

min. no(0)

Minimum  temperature  to 
activate the steam

Defines  the  minimum  temperature  in  the 
oven to allow activating the steam output. 
To  disable  this  function,  change  the 
adjustment to the minimum until 

[no,]

is 

displayed.

[f21]

no(-10)
no(14)

500

(932)

ºC

(ºF)

100

(212)

Economic mode - oven idle 
time to switch of the light

Defines  the  time  the  oven  has  to  be  idle 
before  the  controller  enters  in  Economic 
Mode (ECO). When the lightbulb output is 
switched off. Press 

 to leave the ECO 

dddd

mode.

[f22]

no(0) 60

min.

15

Fan output on time

Defines the time the fan will stay active in 
each direction.

[f23]

60

600

sec. 180

Fan output off time

It must be adjusted with the time required 
for  the  fan  to  stop,  so  that  the  rotation 
reversion can be performed smoothly.

[f24]

5

30

sec.

15

SET

Maximum  turbine  off  time 
after deactivation

Automatic  shutdown  of  the 
turbine  after  completion  of 
the cooking time

Set  the  maximum  time  that  the  turbine 
output  will  stay  off  after  being  manually 
deactivated  by  the  user  or  automatically 
deactivated (case 

F26

 and 

I09

 are set to 

YES

) after the time of the process timer has 

elapsed. 

Note:

The  turbine  can  be  switched  off 

manually  or  automatically  only  after  the 
process time has elapsed and the timer is 
reset. If the timer is activated, the turbine 
will be restarted.

Enables the option to automatically switch 
off  the  turbine  output  after  the  timer 
process time has elapsed (case 

I09

 is set 

to 

YES

).

Note:

 The turbine will only be switched off 

after resetting the timer and the output will 
remain off for the time set in function F25 or 
until the timer is activated.

[f25]

[f26]

1

NO

60

YES

MIN.

-

20

NO

 Defines the functions lock mode:

[OFF,]

= functions lock disabled;

[LOC1]

=  partial  functions  lock  1  - 

p r e v e n t s   a d v a n c e d   c o n f i g u r a t i o n 
parameters from being changed;

[LOC2]

=  partial  functions  lock  2  - 

prevents controller parameters from being 
changed, only allowing changing presets;

[FULL]

  =  full  functions  lock,  does  not 

allow any parameter adjustment.

Timer for function lock

Defines  the  time  to  lock  /  unlock  the 
functions. For more information, see item 
7.4 - Functions Lock.

[f28]

1

30

sec.

10

Functions lock 

[f27]

-

OFF FULL

-

LOC1

  

9. SIGNALING 

Upon power up the controller indicates the operating mode of the oven.

9.1 Operating mode signaling 

9.2 Programming signaling

Eletric Oven

Controller configured with the electric oven logic.

Gas-fired Oven

Controller configured with the gas-fired oven logic.

Wood-fired Oven

Controller configured with the wood-fired oven logic.

Controller  configured  with  gas-fired  oven  logic  with  Default  (standard)  mode  enabled, 
without  flame  sensor  monitoring.  For  more  information,  see  item  7.5  Enable  Default 
(standard) operating mode.

Default Mode (standard)

Functions lock active

Does not allow adjusting the parameter
To deactive functions lock, see item 7.4 - Functions lock.

Parameter adjustment denied

Enter access code in parameter 

[Cod]

to adjust the parameter value.

Receiving data via EasyProg* (programming key)

Updating the parameter table via EasyProg*.

*sold separately 

9.3 Process signaling

If the controller detects an error that interferes in the operation of the system, the controller switches off the 
outputs, switches on the audible alarm intermittently, and indicates the detected failure on the display. To leave 
error mode, the controller must be switched off, the fault corrected, and the controller switched on again.
Note: In case the 

I09 -Enable stand-by oven functionality

 function has been set as 

YES

, press the

>

key 

during the error signaling to put the controller in stand-by and reboot it after the informed error is corrected.

Measure: 

Contact Full Gauge Controls.

Measure: 

Contact Full Gauge Controls.

Reason: 

Temperature sensor disconnected or out of range.

Measure: 

Check sensor connections and operation.

Reason: 

Flame sensor shorted with the burner.

Measure: 

Check wheter the flame sensor is making contact with the burner.

Delay  of  the  temperature 
control (GAS-FIRED OVEN)

When the controller tries to ignite the flame, 
for example after the door is opened, the fan 
is activated first and then the flame ignition 
process commences after the time adjusted 
in this parameter has elapsed.

Note:

 This parameter is used when the type 

of oven selected is GAS.

[F11]

no

(0)

30

sec.

5