background image

IN THIS OPERATING MODE THE FLAME SENSOR IS IGNORED AND THE CONTROLLER WILL 
NOT DETECT THE PRESENCE/LACK OF FLAME, BEING ESSENTIAL FOR THE OPERATOR TO 
PAY  SPECIAL ATTENTION  TO  THE  CONTROL  OF  THE  OVEN  IN  ORDER  TO  PREVENT  GAS 
ACCIDENTS.

Use the 

<

 or 

>

 keys to select the desired function. The value can be edited with a quick touch on the

 key.

dddd

Use the

<

 ou 

>

 to change the value and press the 

 key with a quick touch when ready to save the 

dsse

configured value and return to the functions menu. To leave the configuration menu and return to the normal 
operating  mode(temperature  indication),  press

(press  and  hold)  until 

[----]

  is  displayed.

dddd

Access  the  installation  configuration  menu  by  pressing  the

  key  for  4  seconds  until 

dddd

[Func]

is displayed. When 

[CoD]

 is displayed press the

key again (quick touch). Use 

dsdet

the

<

 or 

>

 keys to enter the 

access code 231

 and press

 (quick touch) again when ready.

dddd

SET

SET

SET

SET

SET

SET

Enable fan thermal protection

Enables  stand-by  oven 
functionality

If  enable,  monitors  fan  temperature.  In 
case  of  overheating,  enters  error  mode, 
switching off the outputs of the controller.
 

[ON,]

= Fan thermal protection enable

 

[OFF]

= Fan thermal protection disable.

Enables  stand-by  mode  (switching  off 
control functions)

[i08]

[i09]

OFF

NO

ON

YES

-

-

ON

NO

U n i t   s e l e c t i o n   o f 
temperature

Selects the temperature unit the controller 
will use for its operation

[i03]

ºC

ºF

-

°C

Language selection

Selects the language the controller will use 
to display messages:

[Port]

= Portuguese 

[,EnG]

= English

[,ESP]

= Spanish

[

i04]

PORT ESP

-

PORT

Enables  external  sound 
alarm (buzzer)

Enables  or  disables  the  external  audible 
alarm  (buzzer).  If  enabled,  the  internal 
audible alarm (buzzer) will be disabled.

[i05]

OFF

ON

-

OFF

DESCRIPTION

FUN

MIN MAX UNIT DEFA

FUNCTION

Access Code (231)

Required  when  you  want  to  change 
installation setup parameters. 

[CoD]

Temperature sensor type

[i02]

0

9999

-

0

tc_J tc_H

-

tc_J

Oven type selection

Selects the control type of the oven:
 

[ELE,]

= Electric Oven

 

[GAS,]

= Gas-fired Oven

 

[LEN,]

=

 

Wood-fired Oven

[i01]

ELE LEN

-

GAS

Door digital input signal type

[,NO,]

- normally open contact (NO)

 

[,NC,]

- normally closed contact (NC)

[i07]

NO

NC

-

NO

[i06]

I n t e r n a l   a u d i b l e   a l a r m 
(buzzer) volume

Selects the sound intensity of the internal 
audible alarm (buzzer)

[Min,]

= low volume

[Med,]

= medium volume 

[HiGh]

= high volume

MIN HIGH

-

HIGH

Defines the type of temperature sensor to 
be used with the controller.

6.1 Oven: electric

In this operating mode the controller keeps the heating output on until the oven reaches the oven temperature 
setpoint (SP). The heating output will be activated again when the temperature drops below the setpoint minus 
the hysteresis (F04).

6.2 Oven: gas

In this operating mode the controller automates / monitors the flame ignition and thus the heating of the oven 
through the activation of the gas output, ignition module, and flame sensor input. The controller keeps the heating 
on until the oves reaches the oven temperature setpoint (SP).
Heating will be activated again when the temperature drops below the setpoint minus the Hysteresis (F04).
The controller permanently monitors the flame sensor to ensure the safe operation of the gas-fired oven. In this 
way, if there are any abnotmalities, errors 

Er4

 - Flame Sensor shorted with the burner and 

Er5

 - Lack of 

Flame are indicated. For more information, check item 9 (Signaling).

6.3 Oven: wood

In this operating mode the heating output works as an upper threshold alarm, indicating when the temperature 
exceeds the value adjusted in Oven Temperature setpoint (SP). The audible alarm is also activated to warn the 
user about the overheating. The output and audible alarm are switched off when the temperature drops below the 
Oven Temperature setpoint (SP) inus the Hysteresis (F05) or when the

key in the controller’s front panel is 

dddd

pressed.

6.4 Default Mode (standard)

!

In this operating mode the controller performs the gas type control, however the flame sensor is ignored and the 

controller will not monitor flame presence. The controller will not detect errors 

Er4

 - shorted flame sensor and 

Er5

 - out of gas, resulting in an operating with less safety.

 NOTE:

 The Default Mode (standard) of operation is 

available only when the type of oven is adjusted as gas. To execute this operating mode, check item 7.5 Enable 
Default (standard) Mode of operation.

SET

Operating temperature / Control temperature

0 to 131ºF (0 to 55°C) / 14 to 932°F (-10 to 500°C) 

Operating humidity

10 to 90% UR (without condensation)

Type J or K thermocouple (sold separately)

Fan PTC (sold separately)

Resolution

 

1ºC / 1ºF

Digital Input 
Flame sensor

E1: door micro switch input  

E2 : flame sensor input

Product dimensions / Cutout dimensions (mm)

75 x 75 x 100 (WxHxD) / 67.2 x 67.2

7 relay outputs: 5 (3)A / 250Vac 1/8HP  

12Vcc / 30mA (max)

Power supply / Approximate consumption

TO711F

: 85~240Vac

 ±

 10% (*) (50-60Hz)  / 10VA

TO711FL

: 12~24Vac/Vdc

 +

 10%  / 10VA 

Thermostat and timer for the automation of forced convection ovens. This model provides control over gas, 
electric,  or  wood  powered  ovens,  configured  through  the  setup  menu.  The  preset  mode  provides  20 
configurations to control the temperature, cooking time, and steam injection, making the oven ready for the most 
varied types of cooking. 

TO-711F

 allows reversing the rotation direction of the fan to improve the uniformity of 

the roast. The instrument, however, controls steam injection and lighting in the oven, and has an internal audible 
alarm (buzzer) that signals, for example, the end of the roasting process. It also allows for the use of an external 
audible alarm and temperature sensor for thermal protection of the fan, preventing it from overheating. The 
ThermOn line is developed and produced with high-quality raw materials and stands out for its unique and 
distinctive design and intuitive, user-friendly interface to facilitate its operation   and configuration. It offers a 
functions lock feature to prevent third parties from changing the parameters, air-tight front panel that provides 
high protection against the entry of dirt and moisture, and more. Product conforming to UL Inc. (United States and 
Canada).

Baking ovens, stoves;

SET

 TO-711F

REC

Quick  touch:  Increases  parameter  value 
when in programming mode;

Upper  display:  Indicates  the 
temperature  measured  by  the 
sensor or parameter configuration;

Lower  display:  Indicates  the  cooking  time  or  parameter 
configuration;

Te m p e r a t u r e   u n i t s   L E D 
indicator;

Quick  touch:  Temperature 
a n d   c o o k i n g   t i m e 
adjustment;

Press  and  Hold:  Access  to  the 
advanced configuration;

Quick touch: Preset selection;

Press and Hold: Preset configuration;

Quick  touch:  Decreases  parameter 
value when in programming mode;

Quick touch: Steam activation;

Press  and  Hold:  Steam  activation  time 
adjustment;

* When the stand-by mode is enabled (I09 = YES)

Quick touch: Timer activation;

Press and Hold: Activates or deactivates 
turbine output;

P r e s s   a n d   H o l d :   A c t i v a t e s   o r 
deactivates the controller stand-by;

Functions lock LED indicator;

Preset use LED indicator;

Steam output on LED 
indicator;

Timer  activated  LED 
indicator;

Heating on indication LED;

Fan on indication LED;

SET

REC

Each key has an LED to indicate its 
function.  When  the  LED  is  on,  it 
indicates that the key is active and 
can be pressed.

KEY FUNCTIONS

SET

LED

KEY

Ratings outputs for UL Applications

 

1 A Resistive,100,000 Cycles 

240 Vac 

24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 
24Vac / Vdc 

240 Vac 
240 Vac 
240 Vac 
240 Vac 
240 Vac 
240 Vac 
240 Vac 
240 Vac 
240 Vac 

0.5 A Pilot load, 100,000 Cycles 

1/8 HP, 100,000 Cycles 
1 A General purpose, 100,000 Cycles 
1/8 HP, 30,000 Cycles 

0.5 A Pilot load, 30,000 Cycles 
1 A General purpose, 100 Cycles 

1 A Tungsten, 30,000 Cycles
1/8 HP, 30,000 Cycles

0.5 Pilot load, 30,000 Cycles

Resistance 1 / Gas 1 / Alarm 1 

Resistance 2 / Gas 2 / Alarm 2 

Steam valve / Ignition  

Lightbulb  

Fan 1 / Fan 2     

TO711F

 

TO711FL

 

BEFORE  INSTALLING  THE  CONTROLLER,  WE  RECOMMEND  THAT  YOU  FULLY  READ  THE  INSTRUCTION 
MANUAL TO PREVENT POSSIBLE DAMAGE TO THE PRODUCT.

THROUGH  CONTINUOUS  DEVELOPMENT,  FULL  GAUGE  CONTROLS  RESERVES  THE  RIGHT  TO  CHANGE 
THIS MANUAL INFORMATION AT ANY TIME WITHOUT PRIOR NOTICE.

THIS  CONTROLLER  IS  NOT  RESPONSIBLE  FOR  SAFETY  WITH  RESPECT  TO ANY  FLAME  SENSOR,  GAS 
VALVE, OR SPARK IGNITER OF WHICH NEED TO HAVE SAFETY CERTIFICATES (RECOGNIZED IGNITION AND 
GAS  MODULE)  IN  ITS APPLICATION  FOR  FINAL  USE.  THE  FLAME  SENSOR,  THE  GAS  VALVE  OR  SPARK 
IGNITER IN THIS CONTROL WILL BE CONSIDERED SEPARATELY FROM THE THERMON CONTROLLER.

Heating

Buzzer

Steam

Lighting

Fan

Functions

Block

Serial

programming

Protection

level

IP 65

FRONT

Presets

Timer

OVEN TIME AND TEMPERATURE CONTROLLER

TO71

1FV02-01T

-17368

TO-711F 

V

er

.02

Have this manual in your hand 

using the 

FG Finder

 app.

6.  OPERATION

  

  

  

1. DESCRIPTION

2. APPLICATIONS

5.1 Installation setup table

4. INTRODUCTION

5. INSTALLATION CONFIGURATION

3. TECHNICAL SPECIFICATIONS

E251415

Relay outputs 

Temperature sensor

External audible alarm (buzzer) outputs

Thermal protection sensor

Reviews: