IN THIS OPERATING MODE THE FLAME SENSOR IS IGNORED AND THE CONTROLLER WILL
NOT DETECT THE PRESENCE/LACK OF FLAME, BEING ESSENTIAL FOR THE OPERATOR TO
PAY SPECIAL ATTENTION TO THE CONTROL OF THE OVEN IN ORDER TO PREVENT GAS
ACCIDENTS.
Use the
<
or
>
keys to select the desired function. The value can be edited with a quick touch on the
key.
dddd
Use the
<
ou
>
to change the value and press the
key with a quick touch when ready to save the
dsse
configured value and return to the functions menu. To leave the configuration menu and return to the normal
operating mode(temperature indication), press
(press and hold) until
[----]
is displayed.
dddd
Access the installation configuration menu by pressing the
key for 4 seconds until
dddd
[Func]
is displayed. When
[CoD]
is displayed press the
key again (quick touch). Use
dsdet
the
<
or
>
keys to enter the
access code 231
and press
(quick touch) again when ready.
dddd
SET
SET
SET
SET
SET
SET
Enable fan thermal protection
Enables stand-by oven
functionality
If enable, monitors fan temperature. In
case of overheating, enters error mode,
switching off the outputs of the controller.
[ON,]
= Fan thermal protection enable
[OFF]
= Fan thermal protection disable.
Enables stand-by mode (switching off
control functions)
[i08]
[i09]
OFF
NO
ON
YES
-
-
ON
NO
U n i t s e l e c t i o n o f
temperature
Selects the temperature unit the controller
will use for its operation
[i03]
ºC
ºF
-
°C
Language selection
Selects the language the controller will use
to display messages:
[Port]
= Portuguese
[,EnG]
= English
[,ESP]
= Spanish
[
i04]
PORT ESP
-
PORT
Enables external sound
alarm (buzzer)
Enables or disables the external audible
alarm (buzzer). If enabled, the internal
audible alarm (buzzer) will be disabled.
[i05]
OFF
ON
-
OFF
DESCRIPTION
FUN
MIN MAX UNIT DEFA
FUNCTION
Access Code (231)
Required when you want to change
installation setup parameters.
[CoD]
Temperature sensor type
[i02]
0
9999
-
0
tc_J tc_H
-
tc_J
Oven type selection
Selects the control type of the oven:
[ELE,]
= Electric Oven
[GAS,]
= Gas-fired Oven
[LEN,]
=
Wood-fired Oven
[i01]
ELE LEN
-
GAS
Door digital input signal type
[,NO,]
- normally open contact (NO)
[,NC,]
- normally closed contact (NC)
[i07]
NO
NC
-
NO
[i06]
I n t e r n a l a u d i b l e a l a r m
(buzzer) volume
Selects the sound intensity of the internal
audible alarm (buzzer)
[Min,]
= low volume
[Med,]
= medium volume
[HiGh]
= high volume
MIN HIGH
-
HIGH
Defines the type of temperature sensor to
be used with the controller.
6.1 Oven: electric
In this operating mode the controller keeps the heating output on until the oven reaches the oven temperature
setpoint (SP). The heating output will be activated again when the temperature drops below the setpoint minus
the hysteresis (F04).
6.2 Oven: gas
In this operating mode the controller automates / monitors the flame ignition and thus the heating of the oven
through the activation of the gas output, ignition module, and flame sensor input. The controller keeps the heating
on until the oves reaches the oven temperature setpoint (SP).
Heating will be activated again when the temperature drops below the setpoint minus the Hysteresis (F04).
The controller permanently monitors the flame sensor to ensure the safe operation of the gas-fired oven. In this
way, if there are any abnotmalities, errors
Er4
- Flame Sensor shorted with the burner and
Er5
- Lack of
Flame are indicated. For more information, check item 9 (Signaling).
6.3 Oven: wood
In this operating mode the heating output works as an upper threshold alarm, indicating when the temperature
exceeds the value adjusted in Oven Temperature setpoint (SP). The audible alarm is also activated to warn the
user about the overheating. The output and audible alarm are switched off when the temperature drops below the
Oven Temperature setpoint (SP) inus the Hysteresis (F05) or when the
key in the controller’s front panel is
dddd
pressed.
6.4 Default Mode (standard)
!
In this operating mode the controller performs the gas type control, however the flame sensor is ignored and the
controller will not monitor flame presence. The controller will not detect errors
Er4
- shorted flame sensor and
Er5
- out of gas, resulting in an operating with less safety.
NOTE:
The Default Mode (standard) of operation is
available only when the type of oven is adjusted as gas. To execute this operating mode, check item 7.5 Enable
Default (standard) Mode of operation.
SET
Operating temperature / Control temperature
0 to 131ºF (0 to 55°C) / 14 to 932°F (-10 to 500°C)
Operating humidity
10 to 90% UR (without condensation)
Type J or K thermocouple (sold separately)
Fan PTC (sold separately)
Resolution
1ºC / 1ºF
Digital Input
Flame sensor
E1: door micro switch input
E2 : flame sensor input
Product dimensions / Cutout dimensions (mm)
75 x 75 x 100 (WxHxD) / 67.2 x 67.2
7 relay outputs: 5 (3)A / 250Vac 1/8HP
12Vcc / 30mA (max)
Power supply / Approximate consumption
TO711F
: 85~240Vac
±
10% (*) (50-60Hz) / 10VA
TO711FL
: 12~24Vac/Vdc
+
10% / 10VA
Thermostat and timer for the automation of forced convection ovens. This model provides control over gas,
electric, or wood powered ovens, configured through the setup menu. The preset mode provides 20
configurations to control the temperature, cooking time, and steam injection, making the oven ready for the most
varied types of cooking.
TO-711F
allows reversing the rotation direction of the fan to improve the uniformity of
the roast. The instrument, however, controls steam injection and lighting in the oven, and has an internal audible
alarm (buzzer) that signals, for example, the end of the roasting process. It also allows for the use of an external
audible alarm and temperature sensor for thermal protection of the fan, preventing it from overheating. The
ThermOn line is developed and produced with high-quality raw materials and stands out for its unique and
distinctive design and intuitive, user-friendly interface to facilitate its operation and configuration. It offers a
functions lock feature to prevent third parties from changing the parameters, air-tight front panel that provides
high protection against the entry of dirt and moisture, and more. Product conforming to UL Inc. (United States and
Canada).
Baking ovens, stoves;
SET
TO-711F
REC
Quick touch: Increases parameter value
when in programming mode;
Upper display: Indicates the
temperature measured by the
sensor or parameter configuration;
Lower display: Indicates the cooking time or parameter
configuration;
Te m p e r a t u r e u n i t s L E D
indicator;
Quick touch: Temperature
a n d c o o k i n g t i m e
adjustment;
Press and Hold: Access to the
advanced configuration;
Quick touch: Preset selection;
Press and Hold: Preset configuration;
Quick touch: Decreases parameter
value when in programming mode;
Quick touch: Steam activation;
Press and Hold: Steam activation time
adjustment;
* When the stand-by mode is enabled (I09 = YES)
Quick touch: Timer activation;
Press and Hold: Activates or deactivates
turbine output;
P r e s s a n d H o l d : A c t i v a t e s o r
deactivates the controller stand-by;
Functions lock LED indicator;
Preset use LED indicator;
Steam output on LED
indicator;
Timer activated LED
indicator;
Heating on indication LED;
Fan on indication LED;
SET
REC
Each key has an LED to indicate its
function. When the LED is on, it
indicates that the key is active and
can be pressed.
KEY FUNCTIONS
SET
LED
KEY
Ratings outputs for UL Applications
1 A Resistive,100,000 Cycles
240 Vac
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
0.5 A Pilot load, 100,000 Cycles
1/8 HP, 100,000 Cycles
1 A General purpose, 100,000 Cycles
1/8 HP, 30,000 Cycles
0.5 A Pilot load, 30,000 Cycles
1 A General purpose, 100 Cycles
1 A Tungsten, 30,000 Cycles
1/8 HP, 30,000 Cycles
0.5 Pilot load, 30,000 Cycles
Resistance 1 / Gas 1 / Alarm 1
Resistance 2 / Gas 2 / Alarm 2
Steam valve / Ignition
Lightbulb
Fan 1 / Fan 2
TO711F
TO711FL
BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND THAT YOU FULLY READ THE INSTRUCTION
MANUAL TO PREVENT POSSIBLE DAMAGE TO THE PRODUCT.
THROUGH CONTINUOUS DEVELOPMENT, FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE
THIS MANUAL INFORMATION AT ANY TIME WITHOUT PRIOR NOTICE.
THIS CONTROLLER IS NOT RESPONSIBLE FOR SAFETY WITH RESPECT TO ANY FLAME SENSOR, GAS
VALVE, OR SPARK IGNITER OF WHICH NEED TO HAVE SAFETY CERTIFICATES (RECOGNIZED IGNITION AND
GAS MODULE) IN ITS APPLICATION FOR FINAL USE. THE FLAME SENSOR, THE GAS VALVE OR SPARK
IGNITER IN THIS CONTROL WILL BE CONSIDERED SEPARATELY FROM THE THERMON CONTROLLER.
Heating
Buzzer
Steam
Lighting
Fan
Functions
Block
Serial
programming
Protection
level
IP 65
FRONT
Presets
Timer
OVEN TIME AND TEMPERATURE CONTROLLER
TO71
1FV02-01T
-17368
TO-711F
V
er
.02
Have this manual in your hand
using the
FG Finder
app.
6. OPERATION
1. DESCRIPTION
2. APPLICATIONS
5.1 Installation setup table
4. INTRODUCTION
5. INSTALLATION CONFIGURATION
3. TECHNICAL SPECIFICATIONS
E251415
Relay outputs
Temperature sensor
External audible alarm (buzzer) outputs
Thermal protection sensor