Hold down simultaneously: enters function selection.
7.3. Basic operations
7.3.1. Adjusting desired temperature (setpoint)
If configured not to use recipes (F03=
[no,,]
):
-
Hold down the
/
key for 2 seconds until the message
[Set,]
is displayed;
- Then the message
[SP,,]
will be displayed and the setpoint may be adjusted;
- Use the
>
or
<
keys for changing the value, then press
/
to confirm.
If configured to use presets
(F03=
[Yes,]
):
Each preset may be set up to use different values for the Setpoint, Control differential (hysteresis) and
Cooling time (interval between defrosts).
To select the preset:
- Hold down the
/
key for 2 seconds until the message
[Set,]
is displayed;
- Then the currently selected preset will appear
[Rc1,]
or
[Rc2,]
.
- Use the
>
or
<
keys to select which of the 2 presets will be used.
- To confirm the selection, press
/
.
Note:
The values of functions Setpoint, Control differential (hysteresis) and Cooling time (interval
between defrosts) for each preset are set up in the parameters menu.
7.3.2. Manual Defrost
Manual defrost can be carried ou through the easy menu, decrement key or digital input.
Defrost using the easy menu:
Press the key
;
(short touch) until the message
[dEFr]
(flashing
@
led) appears, then press the
/
key (short touch) to select. Then the following message will be
displayed
[dEFr][On,,]
(led
@
access). To switch off the defrost manually, press the button
;
(short touch) until the message
[dEFr]
(flashing
@
led) appears. Press the
/
key (short press) to
select. Then the message
[dEFr][OFF,]
(led
@
off).
Defrost using the
<
key (increments):
To activate / deactivate the defrost manually, just press the
<
key for 4 seconds.
Defrost via digital input:
If function
[F35]
- Digital input operation mode is set to
[,,,7]
- Digital
input: Manual defrost, just touch the button (not supplied) connected to the digital input.
<
and
<
<
Quick touch: enters quick access menu.
;
Hold down for 4 seconds: carries out manual defrost.
Note 1:
The minimum and maximum temperature records shall only be performed after the elapsing of
the alarm inhibition time when energizing the controller and after the delay in the instrument
energizing
[,F32]
+
[,F19]
.
Note 2:
The minimum and maximum temperature records shall only be performed after the compressor
reaches the active preset setpoint ; before that, the
[____]
messages will be displayed for the records
of minimum and
[++++]
for the records of maximum temperature.
7.3.7. Unit Selection
To select the temperature unit in which the instrument will operate enter the function
[,F01]
using the
access code
[,231]
then press the
/
. key. Then, select the unit desired
[,=C,]
or
[,=F,]
using
the
<>
keys; to confirm press
/
. Every time the unit is changed, the functions settings return to the
default value, thus, they must be set up again.
7.3.8. Buzzer inhibition
When activated, the buzzer can be inhibited by pressing the
>
key for two seconds. The Buzzer will
remain inhibited until a new alarm event takes place.
7.4. Advanced operations
The functions menu can be accessed through the quick access menu (according to chapter 6), option
[Func]
or by pressing simultaneously
during the temperature display. To allow change of
>
and
<
parameters, enter
[,F01]
by pressing
(quick touch) and using the
keys enter code 123
/
>
or
<
(one hundred and twenty-three), and then confirm with
. For changing the other functions, browse the
/
menu through the
keys and proceed the same way in order to adjust them. To exit the menu
>
or
<
and return to the normal operation, press
(long touch) until
[----]
is displayed.
/
OBS:
If the functions lockdown is enabled, when pressing the
keys, the controller will display
>
or
<
the message
[LOC,]
and will not allow parameter adjustment.
7. OPERATIONS
6.1. Quick Access Menu Map
To access or browse in the quick access menu, use the
;
key (quick touch) while the temperature is
being displayed by the controller. Each touch displays the next function of the list; for confirming, use
the
/
key (quick touch). For further details, refer to chapter 6.3.
7.2.
Quick access keys map
When controller is on temperature display mode, the following keys can be used as a shortcut for the
following functions:
Quick touch: display of current process and sensor temperature when
[F41]
= 1 or 2.
Quick touch: maximum and minimum temperature display.
Hold down for 2 seconds: setpoint adjustment.
/
<
<
<
Hold down for 2 seconds: inhibit audible alarm (buzzer).
Pressed for 5 seconds: turn on/turn off the control functions.
;
Vinyl protector - Image IX (item 13)
Protects the controller should when installed in a place with splashing water, such as in refrigerated
counters. This adhesive vinyl accompanies the instrument, on the packaging.
IMPORTANT:
Apply only after completing electrical connections.
a)
Retract the lateral locks (Image VI - item 13);
b)
Remove the protective film from the adhesive side of the vinyl;
c)
Apply the vinyl over the whole top, folding the flaps, as indicated by the arrows - Image IX (item 13);
d)
Reinstall the latches.
Note:
The vinyl is transparent, allowing to visualize the electric scheme of the instrument.
7.3.3. Functions lockdown
The use of the functions lockdown brings greater security to the operation of the instrument. When it is
active, the setpoint and other parameters can be visible to the user, but are protected against undue
changes
or you can block changes of control functions and leave the adjustment of the
(
[F42]
=2)
setpoint enabled(
[F42]
=1).
Using the key
(short touch), access the function
[LOC,]
in the easy menu, confirm by pressing
/
;
(short touch), then the message
[no,,]
will be displayed. After that keep the key
>
pressed for the
time configured for the functions lockdown
until
[LOC,]
is displayed. The message
[On,,]
[F43]
,
will be displayed indicating the lockdown function is activated upon releasing the key.
To unlock, turn the controller off and then turn it on again with the key
>
pressed. Keep the key pressed
until
[LOC,]
is displayed. Keep the key pressed for ten seconds and the message
[OFF,]
will be
shown on the display indicating the deactivation of the lockdown
function when the key is released.
7.3.4. Shutdown of Control Functions
Turning off control functions allows the controller to operate only as a temperature indicator, keeping the
control outputs and alarms off. The use of this feature is enabled or not by the Shutdown of Control
Functions feature
[,F44]
. When enabled, the control and alarm functions are turned off
(
[CtrL][OFF,]
) or turned on (
[CtrL][On,,]
) through the menu provided in the option
[CtrL]
. When the control functions are switched off, the message
[OFF,]
will be displayed
alternately with the temperature and other messages. Control functions can be switched off / on by
pressing the key
;
for 5 seconds or by setting the
[,F35]
function - Digital input operation mode to
[,,,8]
- Digital input: To switch off the manual control, just touch the button (not supplied) connected
to the digital input to activate or deactivate this functionality.
Note:
When restarting the control functions, the times defined in the functions are counted, and these
delay the powering up of the instrument and the alarm inhibition time when switching on the controller.
7.3.5. Visualization of Processes
To view the process and the time elapsed, press
>
(quick touch) or by the
;
(Flatec) key pressing it
until the message
appears. This way, the controller will display the current process status, and
[Proc]
the following messages may appear on the display:
[dEL,]
- Initial delay (delay in the instrument start-up)
[rEFr]
- Cooling
[Hot,]
- Heating
[dEFr]
- Defrost
[drAi]
- Drainage
[----]
- Control functions off
Not
e:
If the function
[,F41]
- Display indication has been set to
[CooL]
or
[,USE]
, the message
of the process in progress will be displayed, the time elapsed from this process and then the message
[temp]
followed by the display of the measured temperature by the sensor, for a few seconds on the
display.
7.3.6. Minimum and Maximum Temperature Record
Pressing down the
<
key or also via the quick access menu (see chapter 6), will cause the message
[rE9,]
to be displayed, then the minimum and maximum temperatures recorded.
F
or erasing the current minimum and maximum values, hold down the
;
key (quick touch) until the
message
[CrE9]
is displayed, then the message
[CodE]
will appear; enter the value
[,123]
,
then confirm with the
/
key. If the code is correctly entered, the message
[rSt,]
will be displayed.
[rSt,]
. This procedure keeps unauthorized users from erasing the minimum and maximum
temperature records.
;
;
;