MCSOLADV
ANRST02-01T
-17099
1. DESCRIPTION
The
Microsol
RST Advanced
is a digital thermostat with control logic for
heating or cooling. The unit is equipped with a clock, events schedule for rational and
economical use of the controlled load, and protected access to configuration parameters.
It features the Holiday function which saves on power consumption during periods when
the system is idle.
The
Microsol
Advanced
line is characterized by its unique design for use in
residential environments, by the easiness of operation with keys for easy access to the
controller's main resources and by the use of the custom display. The display technology
employed allows presenting in a complete and simple manner the solar heating system's
information, such as: output status, thermostat operation mode, sensor temperature and
time.
2. APPLICATION
- Heating systems for thermal reservoirs
- Floor heating
- Air conditioning
3. TECHNICAL SPECIFICATIONS
- Power:
Microsol
RST Advanced
:
-10%(50/60Hz) or version 115Vac
+-10%(50/60Hz)
- Operation temperature:
0 to 40ºC
- Operation humidity:
10 to 90% UR (without condensation)
- Sensors:
The
Microsol
RST Advanced
has 1 sensor:
Sensor T1:
Thermostat - SB41 Sensor, plastic tip, 2m
- Control temperature:
Sensor T1:
-50 to 105ºC / -58 to 221ºF
- Resolution:
0.1ºC between -10 and 100ºC and 1ºC in the remainder of the range
1ºF in all of the range
- Control output:
The
Microsol
RST Advanced
has one relay output
:
AUX
- Relay output, max. 16A, resistance
3500W in 220Vca (1750W in 127 Vca)
- Dimensions:
104 x 148 x 32 mm
- Display:
LCD 2.75'' with backlight
5. OPERATIONS FOR DOMESTIC USER
5.1 KEY MAP
The controller has easy-access to user resources. Contains table with description of the
following:
Short key press: set the thermostat temperature
Long touch (4 seconds): access to advanced settings
Long touch (see F10 parameter): enables/disables function block
Short key press: access the menu to set the events schedule
Short touch: switches way thermostat mode (AUT / MAN)
Long key press (4 seconds): enables/disables thermostat Holiday mode (OFF)
Short touch: accesses hour and day settings menu
DIGITAL THERMOSTAT
WITH EVENTS SCHEDULE
Ver. 02
SET
SET
RST
Advanced
4. INDICATIONS AND SCREEN
4.1 PRESENTATION
1
2
3
4
5
6
7
8
9
10
11
Schedule key
Thermostat mode key
Clock key
Lowering key
Set key
Increasing key
Indication of the thermostat operation mode
Controller signals
Representation of the solar heating system
Lower display numbers
Upper display numbers
4.2 INDICATIONS
SET
LOC
5.2 THERMOSTAT TEMPERATURE
Sets the operating temperature of the thermostat.
To adjust this parameter, short press the
SET
button. Use the and keys to
adjust the value. To confirm, short press the
SET
button and the value will be
saved in the controller memory. This parameter can be adjusted between the
values defined in the advanced configuration for parameters:
[,F03]
–
Minimum value of the thermostat temperature and
[,F04]
– Maximum value
of the thermostat temperature.
5.3 THERMOSTAT OPERATING MODE
With each short press of the button you can change the operating mode of the
thermostat output between AUT and MAN modes.
Note:
When adjusting the thermostat mode, the controller changes into the new mode 5
seconds after your selection. This is also the time required for the parameter to be stored in
its memory.
Manual mode is used when you wish to control the load outside the hours set in the events
schedule.
In manual mode, the thermostat output is still associated to the sensor temperature via the
thermostat heating temperature (
[TEMP]
parameter). In this mode, the controller allows
the output to be turned on during the period programmed in the parameter
[,F05]
.
AUX
AUT
AUX
MAN
SET
AUT = Thermostat in automatic mode, operating
according to the configuration of the events
schedule and sensor temperature.
MAN = Thermostat in manual mode. It remains in
this mode for the time set in
[,F05]
- thermostat
manual override time, and returns to AUT mode
after this time has elapsed.
5.3.1 VACATION MODE
To enable/disable the Vacation mode, the key must be held for 4 seconds.
OFF: vacation mode enabled.
When enabled:
The event schedule is ignored, the support outlet is turned off, resulting in energy
consumption reduction.
Obs.:
In thermostat mode settings, the controller takes on the new mode 5 seconds after
its selection. This also is the time necessary for the parameter to be stored in its memory.
4 seconds
off
AUX
A
SET
1
2
3
6
5
4
AUX
am pm
SET LOC
AUX
AUT
off
MAN
am pm
7
11
8
9
10
A
A
A
A
am
pm
AUX
In programming, cleared parameter setting
In programming, blocked parameter setting
Fahrenheit scale temperature Indication
Celsius scale temperature Indication
Thermostat output on, if F01=Cool
Thermostat output on, if F01=Heat
Indicates the occurrence of a controller error
Function block setting
Before noon (standard clock 12pm)
After noon (standard clock 12pm)
RST
AUX
AUX
AUT