Full Gauge Controls ANASOL 115vac Quick Start Quide Download Page 2

Using the  

key, it is possible to change, the operating mode of the thermostat output. The thermostat 

MlM

can operate in three different modes:

Access  the  settings  menu  by  pressing  the 

key  for  4  seconds  until 

[F01]

  appears,  wich 

SET

corresponds to the first item in the list of functions. Use the 

 or 

keys to select the desired 

UPP

DOW

function. By short pressing the

 key it is possible to edit its value. Use the 

 or 

keys to 

SET

UPP

DOW

change the value, and when ready, briefly press the 

 key to memorize the set value and return to the 

SET

function menu. To exit the menu and return to the normal operation (temperature indication) press the 

SET

 key (long press) until 

[---]

appears.

Note¹: When the MAN (MANUAL) mode is selected, the thermostat will operate in this state for the 
length of time set by the 

[F08] 

function - The maximum length of time the output will remain on in 

manual mode. After this, the controller switches to the OFF mode.

5.3 THERMOSTAT OPERATING MODE

 MAN = Thermostat in manual mode

AUT = Thermostat in automatic mode operating
according to the sensor temperature

OFF = Circulation

 OFF = Thermostat output always off

Short press

Long press 4
seconds

Short press

6. ADVANCED OPERATIONS FOR INSTALLERS 

(TECHNICAL USE)

6.2 TABLE OF PARAMETERS

6.1 CHANGING THE CONTROLLER PARAMETERS 

6.3 DESCRIPTION OF PARAMETERS

MIN

MAX

UNIT

DEFAULT

DESCRIPTION

FUN

Difference (T1-T2) required to switch off the pump

[F02]

1.0

40.0

°C

4.0

Overheating temperature (T1) required to switch 
off the pump

[F04]

0.0

200

°C

90.0

Operating mode

Maximum time for the output to be on in manual 
mode

Maximum  set  value  allowed  for  the  desired 
temperature (SP)

T2 sensor indication offset

[F06]

[F08]

[F10]

[F12]

[DIF]

Off (0)

F09

-20.0

[REF]

720

105

20.0

-

min.

°C

°C

[DIF]

360

105

0.0

F01 - Differential (T1-T2) to switch on the pump:

It  allows  configuring  the  temperature  difference  between  the  solar  collector  and  the  pool/thermal 
reservoir to switch on the circulation pump. As the solar collectors receive energy, the temperature at 
sensor T1 increases, and when this temperature is a set value over the temperature of sensor T2, the 
pump is switched on and the heated water circulates and is stored in the pool/reservoir.

F02 - Differential (T1-T2) to switch off the pump:

It allows configuring the temperature difference between the solar collector and the thermal reservoir to 
switch off the circulation pump. With the pump on, the temperature difference between the collector and 
the reservoir (T1-T2) tends to decrease. When this value drops to a set value, the pump is switched off, 
stopping the circulation of water.

F03- Defrost temperature (T1) required to switch on the pump:

When the temperature of the collectors (T1) is too low (e.g. winter nights), the pump is turned on, 
depending  on  the  set  temperature  of  this  parameters,  to  prevent  water  from  freezing  in  the  solar 
collector and damaging it. The hysteresis of this control is fixed and set at 2.0°C. The minimum pump on 
time is fixed and set at 2 minutes, to ensure that the water will pass through all the collectors. Even if the 
T1 sensor temperature exceeds the defrost temperature (parameter 

[F03]

), the controller obeys the 

minimum (fixed) time. To disable the defrost function, change he setting to the minimum until OFF is 
displayed.

F04- Overheating temperature (T1) required to switch off the pump:

When the temperature in the collectors (T1) is above the value set in this parameter, the pump is turned 
off in order to prevent the overheated water from circulating through the pipes and damaging them, if 
PVC pipes are used, for example. The hysteresis of this control is fixed and set at 2.0°C.

F05 - Vacuum tube function:

[OFF]

: Vacuum tube function disabled;

[TUP]

: Vacuum tube function for swimming pool;

[TUB]

: Vacuum tube function for bath.

If the 

 function is enabled, the controller activates the vacuum tube mode with parameters set for 

[TUP]

pool. If the 

 function is enabled, the controller activates the vacuum tube mode with parameters 

[TUB]

set for bath. These parameters determine the pump on period and time, in addition to the minimum 
collector temperature (T1) and the maximum differential (T1-T2), corresponding to the thermal shock 
protection to activate the function. There are some models of vacuum tube collectors where it is not 
possible to directly measure the collector temperature, as they do not take readings from immersion 
sensors. To accurately measure the water temperature at the outlet of the collector, a minimum amount 
of water must be flowing. For this, the solar circuit must activate the pump at regular intervals so that the 
water heated in the collector passes over the T1 sensor. When the vacuum tube function is enabled, 
thermal  shock  protection  is  activated,  which  prevents  the  pump  being  switched  on  when  the 
temperature of the collector is much greater than the reservoir.
Note: the controller prioritizes the protection settings (overheating), and if they are engaged, ignores the 
vacuum tube function.

F06 - Operating mode:

Allows  configuring  the  operating  mode  of  the  controller  as  differential  control  (solar  heating)  or 
thermostat for heating or cooling. When configured as differential, sensor T1 is used in the collector and 
sensor T2 for the reservoir. When configured as a thermostat, only the T1 sensor is used.

[dIf]

: Differential mode;

[Hot]

: Thermostat heating mode;

[ref]

: Thermostat cooling mode.

F07 - Temperature control hysteresis:

Allows  configuring  the  hysteresis  temperature  for  both  differential  control  and  thermostat  mode. 
Through this function it is possible to set a temperature range within which the output will remain off.

For exemple: If set SP = 30.0 and 

[F07]

 = 1.0, heating of the pool/thermal reservoir will be turned off 

when the temperature of the T2 sensor reaches 30.0°C, and will only switch on again to heat up, when it 
falls below 29.0°C (30.0-1.0 = 29.0).

F08 -Maximum time for the output to be on in manual mode:

It is the length of time that the pump or thermostat output will remain on in manual mode. After this 
period,  the  controller  in  differential  operation  mode  switches  to  AUT  (automatic)  mode,  and  in 
thermostat mode it switches OFF.

Note: In differential operating mode, if this parameter is set to OFF, it does not switch the pump on. In 
thermostat operating mode, if this parameter is set to OFF, the output will activate until reaching the 
desired temperature (SP), after this period, the controller will switch to OFF mode.

F09 - Minimum set value allowed for the desired temperature (SP):
F10 - Maximum set value allowed for the desired temperature (SP):

These parameters serve as lower and upper limits for setting the SP parameter (desired temperature in 
the pool/thermal reservoir or thermostat). They are used to block the temperature adjustment in order to 
restrict inappropriate configuration, for example. A high value can keep the thermostat output on for a 
long time, increasing energy consumption.

F11 - T1 sensor indication offset:
F12 -T2 sensor indication offset

It allows compensating for possible deviations in the reading of sensors T1 (collector or thermostat) and 
T2 (reservoir), due to a sensor being replaced or change in cable length.

  

7. SIGNALS

Reason: 

Sensor 1 disconnected or outside the specified range.

Action: 

Check sensor connections and operation.

Reason: 

Sensor 1 disconnected or outside the specified range.

Action: 

Check sensor connections and operation.

Reason: 

Sensor 1 temperature below the temperature set in 

[F03]

.

Antifreeze protection.

Overheating protection.

Reason: 

Sensor 1 temperature above the temperature set in 

[F04]

.

Actions: 

Contact the technician responsible for the installation.

Actions: 

Contact the technician responsible for the installation.

T1 sensor indication offset

[F11]

-20.0

20.0

°C

0.0

Minimum  set  value  allowed  for  the  desired 
temperature (SP)

[F09]

-20.0

F10

°C

-20.0

Temperature control hysteresis

[F07]

0.1

20.0

°C

1.0

Vacuum tube function

[F05]

[Off]

[TUb]

-

[Off]

Defrost temperatura (T1) required to switch on 
the pump

[F03]

Off (-19)

10.0

°C

8.0

Difference (T1-T2) required to switch on the pump

[F01]

1.0

40.0

°C

8.0

In automatic mode, activates the output when the 
temperature is below the desired temperature.

Note²: This operating mode is available when set to

 [F06]

 - 

[Hot]

 (Heating Thermostat Mode) or 

F06 - 

[rEF]

 (Cooling Thermostat Mode).

[F06]

 = 

[Hot] 

or 

[rEF]