![FULGOR FSH 905 ID TS Manual Download Page 29](http://html.mh-extra.com/html/fulgor/fsh-905-id-ts/fsh-905-id-ts_manual_2344947029.webp)
29
GB
Error
message
Description
Possible error
reason
Troubleshooting
Er36
NTC value is not
within its
specification
(value < 200mV or
> 4.9V; control unit
cuts off
Short-circuit or
cut-off at
NTC
Exchange control
unit
Er31
Configuration data
incorrect
Configuration of
induction
necessary
New
Configuration
Er47
Communication
error between
TC and induction
None or faulty
communication!
Ensure that
connection cable
is plugged on
correctly and
functional.
E2
Overheating of the
induction coils
Cooling down
necessary
U400
Secondary voltage
of the power unit
to high (primary >
300V). Control unit
cuts off after 1 sec
releasing a
permanent tone.
Control unit is
wrongly
connected.
Connect to
correct mains
voltage
E5
Error on filter
board
Exchange filter
board
E6
Error on power
unit
Exchange power
unit
E9
Coil temperature
sensor
defective
Exchange
temperature
sensore