EN
39
PROBLEM
POSSIBLE CAUSE
SOLUTION
The barbecue doesn’t light
No gas
Check that the shut-off valve is open (ON)
Gas cylinder empty - refill or change the cylinder
The ignition system is not
working
Check the battery - you should hear a clicking
sound when you press the knob
Replace the battery
Light the barbecue manually
Gas tap regulated too high
Clean and delicately dry the electrode making sure
that its position is correct
Excessive smoke from the
cooking surface
Gas valve set too high
Lower the gas or turn off some of the burners
Odour of gas
DON NOT TRY TO LIGHT THE
APPLIANCE
Gas leak
Close the gas with the shut-off valves
Check for leaks, tighten the fittings
If the problem persists, call the Service Centre
13 - Troubleshooting
Summary of Contents for FOBQ 1000 G MBK
Page 2: ......
Page 18: ...EN 16 Detail of the gas connection 52 47 488 With note natural gas connection NG ...
Page 25: ...EN 23 Mod BBQ 100 cm 5 5 1 25 Mod BBQ 80 cm 5 5 8 ...
Page 26: ...EN 24 Mod BBQ 60 cm 5 5 585 Mod BBQ 100 80 60 cm 700 135 240 660 25 105 ...
Page 29: ...EN 27 BP 5 kg BUTAGAZ 6 kg CALOR 5 kg PRIMAGAZ 5 2 kg ...
Page 43: ......
Page 44: ...DOC COD 1 00A 34 3 03 21 ...