LED Details

Ready LED

Indicates the operational state of the switch.

Error LED

Indicates a USB memory mount/access error occurred.

PSU LED

Indicates the switch power supply status.

Check LED

Lights orange when there is a problem. In such case, consult with the vendor's service 
representative immediately.

Flash LED

Indicates the read/write status of the USB memory inserted into the switch.

Precautions

When the Flash LED is lit green, do NOT turn off power or reset the switch. The configuration being read or written may 
be corrupted.

Ext.PSU LED

Indicates the status of the redundant power supply. Not supported.

Link/Act/Speed LED

Indicates the link status and communication speed/status of the RJ45 port.

Fdx LED

Indicates whether the RJ45 port is operating in half or full duplex mode.

SFP Link/Act LED

Indicates the link status and communication speed/status of the SFP module.

SFP LED

Indicates the link up/down status of the SFP module.

Check

Flash

Ext.PSU

Ready

Error

PSU

Link/Act/Speed

Fdx

SFP

 

Link/Act

SFP

Summary of Contents for XG0448

Page 1: ...Hardware Guide XG0448 XG0448 TA41001 7425 XG0448 Hardware Guide Introductory ...

Page 2: ...stall your XG0448 and should be read and understood before you start using your XG0448 First edition February 2011 This manual contains the technology regulated by Foreign Exchange and Foreign Trade Control Law Therefore when this manual is exported or provided to a nonresident the appropriate permission based on this law is required Screenshots are used according to the guidelines provided by Mic...

Page 3: ...h correction free of charge within ninety 90 days of Customer s purchase of the Product Warranty Period 2 During the Warranty Period if the said discrepancy between the Documentation and the Software cannot be corrected despite Fujitsu s repeated corrections or provision of information within reasonable limits as set forth in subsection 1 above Fujitsu shall be liable for damages incurred to Custo...

Page 4: ...the warranty with respect to such third party software is limited to those warranties provided by Fujitsu hereunder and the third party vendor does not provide any further warranties with respect to such third party software 5 High Safety Required Use The Customer acknowledges and agrees that the Software is designed developed and manufactured as contemplated for general use including without limi...

Page 5: ... 14 Laser Safety 15 Notes on Rack Mounting and Connecting a Powerstrip 15 About Fujitsu s Green Products 15 Notes on Use 16 Chapter 1 Getting Started 17 1 1 Items in the Package Descriptions and Functions 18 1 1 1 Parts List 18 1 1 2 Port Side 19 1 1 3 Power Inlet Side 22 1 1 4 Top Surface 22 1 1 5 Bottom Surface 23 1 2 Options 24 1 2 1 SFP Modules 24 1 2 2 SFP Modules 24 1 2 3 Expansion Card 25 C...

Page 6: ...8 Hardware Guide Contents 6 2 3 4 Connecting Twisted Pair Cable SFP Module CX4 Cable 39 2 3 5 Plugging in the USB Memory 41 2 4 Connecting a Setup PC 42 2 5 Time Setting 45 2 6 Set up IP address 46 Index 47 ...

Page 7: ...dge of network and the Internet is required Areas Covered The organization of this manual and the contents of each chapter are shown as follows About the Symbols The symbols used in this manual have the following meanings Chapter Titles Contents Chapter 1 Getting Started This chapter lists the items that should be in the product package and describes the names and functions of the various componen...

Page 8: ...operating system Windows 2000 Microsoft Windows 2000 Professional operating system Microsoft Windows NT Server network operating system Version 4 0 Windows NT 4 0 Microsoft Windows NT Workstation operating system Version 4 0 Microsoft Windows Server 2003 Standard Edition Windows Server 2003 Microsoft Windows Server 2003 R2 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft...

Page 9: ...uals as necessary Manual Name Description Safety and Installation Guide This manual describes the safety and installation XG0448 Hardware Guide This manual This manual describes the hardware of the XG0448 User s Guide This manual describes a variety of operations and procedures including the installation and maintenance of the XG Series ...

Page 10: ...cause severe damage to person resulting in serious injury or death Indicates that improper use can cause light or moderate injury In addition this symbol indicates a chance of damage to this device and other connected equipment Symbols Definitions The symbol in form indicates a warning or cautionary note Specific information is shown inside or next to the symbol The symbol in form indicates a proh...

Page 11: ... in electric shock If you notice abnormal conditions such as overheating smoke emission or odor stop using this device immediately and pull the power cable plug from the socket Make sure that abnormal conditions such as smoke no longer exist and contact our engineer or an engineer certified by Fujitsu Continuing to use the device in this condition may result in electric shock or fire Do not insert...

Page 12: ...tic fields Failure to follow this may cause system failure Ensure enough space for access to and cabling of the device For multiple devices ensure adequate service areas front and back for both devices Failure to follow this may cause cable failures Make sure to unplug the power cable when transporting this device Failure to follow this may cause system fault Do not use any extension card other th...

Page 13: ...ed device Modification and disassembly are not permitted under any circumstances Use of the device or upgrading the device firmware implies acceptance of the End User License Agreement stipulated within the User s Guide Eliminating Static Electricity from Twisted Pair Cables Grounding Under certain conditions twisted pair cables can become charged with static electricity Connecting a statically ch...

Page 14: ... weapons systems Do not use the XG0448 for High Safety Required applications without otherwise ensuring the safety level required Fujitsu and its related companies assume no liability whatsoever for damages arising from use of the XG0448 by the user in High Safety Required applications and for any claims or compensation for damages by the user or a third party FCC WARNING Changes or modifications ...

Page 15: ...exhaust ventilation surfaces Make sure to check the maximum loading capacity of the rack to be used for mounting Check the power supply capability of the installation location When connecting the power cable of the device to a powerstrip within a rack a large amount of current leakage may occur through the ground line of the powerstrip Assure a good ground connection exists before connecting power...

Page 16: ...otection circuit against lightning and electrostatic discharge Therefore some of the functions may not work when lightning or static electricity enters the device In such case the device can be restored to its normal condition by power cycling the device If the functions are still not available after power on or if the power itself cannot be turned on the device may have been destroyed due to ligh...

Page 17: ...cribes the names and functions of the various components 1 1 Items in the Package Descriptions and Functions 18 1 1 1 Parts List 18 1 1 2 Port Side 19 1 1 3 Power Inlet Side 22 1 1 4 Top Surface 22 1 1 5 Bottom Surface 23 1 2 Options 24 1 2 1 SFP Modules 24 1 2 2 SFP Modules 24 1 2 3 Expansion Card 25 ...

Page 18: ...l fitting which attaches to the back side of the rack to fix the switch onto the rack M3 Countersunk Screws Qty 8 Screws for fastening the switch on to the rack rails CD ROM Contains the User Guide in a PDF format Adobe Reader is required for viewing Safety and Installation Guide This manual describes the safety and installation of the XG0448 XG0448 Hardware Guide with Licence Agreement This manua...

Page 19: ...ot be used SFP Slots Installing an SFP module in a SFP slot will allow connection to a 100BASE FX 1000BASE SX 1000BASE LX 1000BASE ZX 1000BASE BX D 1000BASE BX U optical cable Its associated RJ45 port can no longer be used USB Port Insert a USB memory device to load save configuration files or update firmware Dump Switch Press the dump switch to copy the following switch files to an installed USB ...

Page 20: ...B memory inserted into the switch Precautions When the Flash LED is lit green do NOT turn off power or reset the switch The configuration being read or written may be corrupted Ext PSU LED Indicates the status of the redundant power supply Not supported Link Act Speed LED Indicates the link status and communication speed status of the RJ45 port Fdx LED Indicates whether the RJ45 port is operating ...

Page 21: ...ower is off Check Orange A problem occurs which may require switch replacement Orange Blinking Firmware in the internal flash memory of the switch is destroyed Off The switch is operating normally Flash Green USB memory is inserted correctly Green Blinking A USB memory read write operation is occurring Off USB memory is not inserted Ext PSU Off Not supported Link Act Speed Green Established 1000M ...

Page 22: ...C power inlet for the power cable provided Redundant PSU Connector Connector for an external redundant power supply Not supported MAC Address Label This indicates the MAC address of the switch 1 1 4 Top Surface Warning Label This label describes the safety measures you should take when using this product Reference 1 2 3 Expansion Card pg 25 Power Inlet Redundant PSU Connector Expansion Slot SLOT1 ...

Page 23: ...ge Descriptions and Functions 23 1 1 5 Bottom Surface Product Manufacturing Label This indicates the model name serial number manufacturing date and Class 1 Laser Product etc Firmware Label This indicates the firmware version Product Manufacturing Label Firmware Label ...

Page 24: ... 45 through 48 are combination ports that are associated with the four SFP ports Their use is mutually exclusive If the RJ45 port 45 is cabled then the associated SFP slot cannot be used 1 2 2 SFP Modules SFP modules 10GBASE SR 10GBASE LR are intended for use in the optional extension card Precautions Turn the switch power off to install a SFP module SFP modules can not be installed in an SFP slot...

Page 25: ...ard SFP Expansion Card SFP Link Act LEDs Indicated the link status communication status of the SFP port SFP Slots Installing an SFP module in either SFP slot will allow connection to a 10GBASE SR or 10GBASE LR optical cable LED Display Content LED Name State Status SFP Link Act Green Link is established with SFP Green Blinking 10GBASE SFP data traffic activity Off Link is not established Reference...

Page 26: ...us CX4 Ports Connect to 10G Ethernet NW equipment using CX4 cable LED Display Content LED Name State Status CX4 Link Act Green Link is established with CX4 Green Blinking 10G CX4 data traffic activity Off Link is not established Reference 2 2 2 Installation of Extension Card pg 33 User s Guide CX4 Expansion Card pg 27 CX4 Link Act LEDs CX4 Ports ...

Page 27: ...n 31 2 2 1 Installation of the Switch 31 2 2 2 Installation of Extension Card 33 2 3 Connecting the Equipment 35 2 3 1 Discharging Twisted Pair Cable 35 2 3 2 Cleaning SFP Module SFP Module Optical Connector 35 2 3 3 Connecting Twisted Pair Cable SFP Module 37 2 3 4 Connecting Twisted Pair Cable SFP Module CX4 Cable 39 2 3 5 Plugging in the USB Memory 41 2 4 Connecting a Setup PC 42 2 5 Time Setti...

Page 28: ...n Requirements Caution Install the product under the following conditions Using the product outside the required environment may cause failure of the product Temperature and Humidity Requirements Power Requirements Reference 1 1 1 Parts List pg 18 Temperature degrees C Humidity RH Operation 0 to 40 15 to 85 Non operation 0 to 50 8 to 90 Item Requirements Voltage AC90 264V Frequency 50Hz 60Hz 2 4 G...

Page 29: ... Nothing is put on the switch Vents are not obstructed The switch is not located on the table or not stuck on another switch The switch is not located under direct sunshine near heating appliance under high humidity or in a dusty area The switch is not located on unstable places where vibrating or tilting About Warning Descriptionst has been thoroughly read pg 10 Reference ...

Page 30: ...hen installing the switch and providing maintenance ensure the space below is maintained Internal cooling fans of the switch allow the air intake from the left hand side and exhaust at the right hand side Ensure the indicated space below and do not put anything which avoids airflow Port Side 300mm 300mm 50mm 50mm 800mm 800mm 90mm 150mm XG0448 Installation Space Maintenance Space Airflow Airflow 10...

Page 31: ...cure screws according to the specifications of the rack Pay attention to control temperature inside and outside of the rack so that guaranteed operating temperature can be maintained properly for the switch Reserve certain space for air cooling in accordance with the cooling structure of the switch Check if power supply capacity Rated Current is sufficient from the power supply equipment such as p...

Page 32: ...crews are used it may break Also make sure to use cross slot screwdriver corresponding to the screw thread 3 Fix the switch that rack mounting brackets are put at the procedure 2 Precautions Pre occupied devices in the upper and or lower row of the rack may interfere with the power cable of the switch from being properly installed In that case plug the power cable to the switch before install it i...

Page 33: ... the power of the switch Caution Do not install uninstall the extension cards with the power on It may cause trouble 2 Loosen the screws on the extension slot and remove the cover panel 3 Install the extension card slowly sliding on the guide rail inside the extension slot Precautions Rightly install the extension card on the guide rail If not the connection pin may break 4 Firmly fix the extensio...

Page 34: ... is removed when the power is on the Check LED will light up and the switch will go into trouble state 2 Loosen the screws on the extension slot and remove the extension card 3 Put the cover panel on the extension slot and fix it on the switch with the screws Precautions When the switch is operated without the extension card make sure to put the cover panel on the switch ...

Page 35: ... when using ground wire for power suppl 2 3 2 Cleaning SFP Module SFP Module Optical Connector When invisible small dust is adhered to SFP module SFP module optical connector optical signal will be shut or space caused by dust will impede transmission of optical signal Therefore clean up SFP module SFP module optical connector before connection Cleaning of SFP Module SFP module Below describes the...

Page 36: ...d slowly wipe the optical fiber part with cleaning fabric 3 Wipe with a new cleaning stick in the same fashion and dry the optical connector Caution Do not use fluid such as bleach because it will damage optical coupling Use ionizer when cleaning in order to avoid the ESD damage to SFP module SFP module SFP module SFP module cannot be washed with water Do not use or clean SFP module SFP module in ...

Page 37: ...ull duplex mode SFP slot 1000Mbps FULL DUPLEX MODE The flow control can be set by an auto negotiation When 100BASE FX module is used the following settings are necessary fixed at 100Mbps Media type fixed at fiber Connecting Twisted Pair Cable Insert twisted pair cable to 10 100 1000BASE T port until it clicks Precautions In case of 1000BASE T usable twisted pair cables are unshielded twisted pair ...

Page 38: ...or pg 35 for cleaning Do not directly touch the contact part of SFP module by hands Use wristbands when touching SFP module Connecting part to the optical cable of SFP module is the laser opening There are two types of SFP modules veil latch type and standard latch type Below describes how to connect these modules Veil Latch Type Insert SFP module to the SFP slot with a lever locked and lock the m...

Page 39: ...ean the end face of SFP module optical cable before connecting optical connector because the end face may possibly be contaminated Please refer to 2 3 2 Cleaning SFP Module SFP Module Optical Connector pg 35 for cleaning Do not directly touch the contact part of SFP module by hands Use wristbands when touching SFP module Connecting part to the optical cable of SFP module is the laser opening Inser...

Page 40: ...ort and lock the cable Precautions Make sure to firmly insert the cable straight from behind When bending the cable make sure that the diameter of the bent cable does not become somaller than 10cm When pulling out the cable make sure to pull the pull tab of the cable connector The cable may disconnect if you pull the cable itself Type Core Cladding Diameter Minimum Transimission Band Cable Length ...

Page 41: ...interface panel of the switch Replacing the USB Memory Unplug Please refer to the follow instructions 1 Make the USB port to disable status using the console command 2 Check and confirm that USB port is in a disable status Execute command show usb hcd status and check and confirm that the status is displayed as disable 3 Unplug the USB memory from the switch 4 Plug in the replacing USB memory onto...

Page 42: ...required to connect the set up PC to the switch A RS232C crossover cable is not provided with the switch The console cable adapter which is included in this product is used with the RS232 cable to connect the set up PC to the switch Communication Software Terminal emulation software is required Connect RS232C Cable 1 Confirm power of both the PC and the switch are off 2 Connect the RS232C cable an...

Page 43: ... safety measure to prevent electrical shocks please make sure to connect the ground wire of the change plug Precautions Please set the switch product to a place near the electrical outlet which the power cable will be connected and secure a space for the power cable to be pulled off easily 1 Connect the power cable to the electrical outlet 2 Plug in the power cable to the power connecter of switch...

Page 44: ...dmin and press Return key or Enter key 6 Confirm Password on screen 7 Key in password then press the Return key or Enter key Since password is not set at the initial state simply press Return key or Enter key without keying in the password If the password is already set key in the password Then press Return key or Enter key 8 Confirm is shown on screen If the key in the wrong password invalid pass...

Page 45: ...nually using console or telnet z Command When setting time and date to be Jan 1 2011 12 30 00am type in command date 2011 01 01 12 30 00 XG0448 configure Switch to Configuration mode XG0448 config time zone 0500 When setting time zone to be 0500 XG0448 config commit Apply the configuration XG0448 config save Save the configuration XG0448 config exit Switch to Operation mode XG0448 date 2011 01 01 ...

Page 46: ...nds show how to set up the IP address ex 192 168 1 1 z Command Precautions The IP address is not set at the initial state of the purchase Please set the IP address through console When logging in by console you will not be able to log in from the www browser Please make sure to log off from the console after setting up the IP address XG0448 configure XG0448 config lan 0 ip address 192 168 1 1 24 3...

Page 47: ... LED 20 M M3 Countersunk Screws 18 MAC Address Label 22 O Options 24 organization of the manuals 9 P Port Side 19 Power Cable 18 Power Inlet 22 Power Inlet Sid 22 Power Requirements 28 Prepare a Setup PC 44 Product Manufacturing Label 23 Product Part Number Serial Number Label 19 PSU LED 20 R Rack Mounting Brackets 18 Ready LED 20 Redundant PSU Connector 22 Reset Switch 19 RS232C cable 42 S Safety...

Page 48: ...XG0448 Hardware Guide Index 48 U USB Memory 41 USB Port 19 W Warning Label 22 ...

Page 49: ...her rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu EC declaration of conformity and the technical documentation are kept at the following FUJITSU TECHNOLOGY SOLUTIONS HOLDING B V Het Kwadrant 1 3606 AZ Maarssen The Netherlands Highlight Towers Mies van der Rohe Strasse 8 80807 Munich...

Reviews: