background image

En-1

OPTIONAL KIT INSTALLATION (OPTION)

 This air conditioner can be connected with the following optional kits.

 •  Wired remote controller

 •  Simple remote controller

 •  External connect kit

BEFORE INSTALL WIRED REMOTE CONTROLLER

•  When you use wired remote controller, some functions may not be used.

 CAUTION

•  Before installing, be sure to disconnect all power supply.

•  Don’t touch the heat exchanger.

•  During installing or removing operation, be sure not to have wire caught by parts or 

draw it hard. Or it may result troubles to the air-conditioner.

•  Avoid place in direct sunlight.

•  Select place that will not be affected by the heat from a stove, etc

•  

Before setting up the optional kit, please con

 rm whether air-conditioner can receive 

the signal.

•  Do not connect the wired remote controller to the terminal for power supply.

•  When connecting the wired remote controller with the indoor unit, use the connecting 

cable (supplied with wired remote controller or simple remote controller).

•  Recommended cable length of wired remote controller is 32 ft. (10 m). Make sure to 

do insulate of connecting part when extended the cable.

Do not connect power supply with the terminal.

INDOOR UNIT

PCB

TERMINAL

INSTALLATION WORK

Remote controller cord modi

 cation

(1)  Use a tool to cut off the terminal on the end of the remote controller cord, and then 

remove the insulation from the cut end of the cord.

(2)  Connect the remote controller cord and connecting cord.

(supplied with wired remote controller)

Important:

 Be sure to insulate the connection between the cords.

Connecting cord

White

Red

White

Red

Black

Black

Insulated 

connection

Remote 

controller cord

Remote 

controller cord

25/32 in.  (20 mm)

Installing wired remote controller terminal / 

external connect kit terminal (sold separately)

(1)  Remove the screw on the control box as shown on the top right of the figure below.
(2) Release both bottom clasps at the sides in the direction of the arrow as circled in

the bottom left of the figure below. Pull and remove the cover.

(2)

(1)

Cover

(3)  Connect the wired remote controller terminal / external connect kit terminal (sold

separately) to the specified terminal on the board as shown below. Please connect

to the connector with necessary function according to the actual usage.

(4) After connecting each terminal, thread the cables through the notch as circled on

the bottom right of the figure below.

(3)  Control input (Operation/ 

Stop or Forced stop) con-

nector

: CNA01(White) *

(3)  Wired remote controller 

connector

: CNC01(White) *

* : Symbol indicating the location printed on the board 

(3)  Error Status output 

connector

: CNB02(Black) *

(3)  Operation status 

output connector

: CNB01(White) *

(4)

(5) Install the control box cover as shown below.

(Align the cover with the upper and lower right corners as indicated by the triangular 

symbols on the figure.
Insert the clasps on the cover into both sides at the bottom of the two dotted 

circles.)

•  When installing the control box cover, make sure that the cables are not caught as 

shown in the detail view.

(6) Install one screw.
(7) Screw the earth wire of wired remote controller as shown in the figure. 

(AUSTRALIA model only).

(7)

(5)

(5)

(6)

Cover

Detail view

Installing communication box

Removing intake grille

(1)  Remove the screws (x4). (Use the same screws when installing.)
(2)  Pull the control box cover towards you and remove.

(1)

(1)

(2)

(1)

(1)

(3)  Remove the connectors (x4).

•  Remove and pull off the lock at the side of the connector insertion part.

9333005041_IM.indb 8

11/6/2013 10:33:02 AM

AIR CONDITIONER

OPTIONAL PARTS

External connect kit

,167$//$7,210$18$/

For authorized service personnel only.

Supplemental Manual

Reviews: