background image

1.2" (30

mm)

Remove cable tie

before installation

Cut the end of boot to fit your cable OD.

Disassembly of the plug

Cut off cable tie, remove the boot.

Using flat screw driver and try

gently to open the plug.

Close plug cover,

make sure that the

drain wire (if available)

is in proper contact with

grounding clip on plug.

Pull back strain relief boot

to cover the plug, fasten

supplied cable tie to secure

grounding contact

Place the wiring cap

onto plug , use plier to

clamp wiring cap until it

completely snap in to effect

the connection

Apply all four twisted

pairs according the

color code label

and allocate each

conductor into proper

slots on wiring cap. Keep the

cable length between the cable

sheath and the cable manager as short

as possible. Trim the ends of the conductors.

Insert cable into strain

relief, strip off 30 mm of

the cable jacket, fold back

braid and drain wire

Drain Wire

Cable tie

Open cap

Wiring label

Hama GmbH & Co KG

86652 Monheim/Germany • www.hama.com

00053790

Compact CAT 6a plug suitable for

Round solid cable AWG 23 – 26 (1 x 0,41 – 1 x 0,56 mm)

Stranded cable AWG 24- 26 (7 x 0.16 – 7x 0,20 mm)

Compatible to CAT5, CAT7, CAT7a

1

2a

3

4

5

6

JA

CK

PIN

DESIGNA

TIONS

TIA/EIA

T568A

TIA/EIA

T568B

1 white/green

green

white/orange

orange

2
3 white/orange

blue

white/green

blue

4
5

white/blue

orange

white/blue

green

6
7 white/brown

brown

white/brown

brown

8

2b