1.2" (30
mm)
Remove cable tie
before installation
Cut the end of boot to fit your cable OD.
Disassembly of the plug
Cut off cable tie, remove the boot.
Using flat screw driver and try
gently to open the plug.
Close plug cover,
make sure that the
drain wire (if available)
is in proper contact with
grounding clip on plug.
Pull back strain relief boot
to cover the plug, fasten
supplied cable tie to secure
grounding contact
Place the wiring cap
onto plug , use plier to
clamp wiring cap until it
completely snap in to effect
the connection
Apply all four twisted
pairs according the
color code label
and allocate each
conductor into proper
slots on wiring cap. Keep the
cable length between the cable
sheath and the cable manager as short
as possible. Trim the ends of the conductors.
Insert cable into strain
relief, strip off 30 mm of
the cable jacket, fold back
braid and drain wire
Drain Wire
Cable tie
Open cap
Wiring label
Hama GmbH & Co KG
86652 Monheim/Germany • www.hama.com
00053790
Compact CAT 6a plug suitable for
Round solid cable AWG 23 – 26 (1 x 0,41 – 1 x 0,56 mm)
Stranded cable AWG 24- 26 (7 x 0.16 – 7x 0,20 mm)
Compatible to CAT5, CAT7, CAT7a
1
2a
3
4
5
6
JA
CK
PIN
DESIGNA
TIONS
TIA/EIA
T568A
TIA/EIA
T568B
1 white/green
green
white/orange
orange
2
3 white/orange
blue
white/green
blue
4
5
white/blue
orange
white/blue
green
6
7 white/brown
brown
white/brown
brown
8
2b
Montageanweisung
Instruction Manual