5
C. When routing the cable on-wall:
(1) Cut off the cable guide of the front case with using a knife or a
nipper.
(2) Deburr the edge of the cable guide.
Cut off
Front case
(3) Fix the rear case by securing it with attached screws (2 places).
Screws
Rear case
Remote controller cable
Epoxy putty
5.3.5 Connect the cable to the terminals
Tightening torque
Terminal screw
WR1PWRNJIFP
1. 12V (Red)
2. Signal (White)
3. COM (Black)
Cable tie (small)
Tube
Hole for cable tie
2 mm
GOOD
PROHIBITED
To avoid an excessive tension or pressure to the terminal block,
fix the remote controller cable with the cable tie (small) properly.
Turn off a cable tie (small) by all means on
tube
.
CAUTION
%HFDUHIXOWRDYRLGEUHDNLQJWKHFDEOHE\RYHUWLJKWHQLQJWKHFDEOHWLH
:KHQFRQQHFWLQJWKHUHPRWHFRQWUROOHUFDEOHVGRQRWRYHUWLJKWHQWKH
screws.
5.3.6 Setting the DIP switch
CAUTION
'RQRWVHWWKH',3VZLWFKRIWKLVXQLWH[FHSWDVVSHFL¿HGLQWKLVLQVWDOODWLRQ
manual or the operating manual supplied with the air conditioner.
Please
set DIP switch according to designation.
Use an insulated screwdriver to set the DIP switches.
Set DIP switch No. 1 to ON to enable the memory backup of the settings
information.
Memory backup setting
,IWKH',3VZLWFK1RLVQRWVHWWR21WKHVHWWLQJVLQIRUPDWLRQZLOOEHORVW
if there is a power failure.
5HJLVWHUHGLQIRUPDWLRQVXFKDVWKDWIRUWKHLQWHUQDOXQLWLVQRWHUDVHG
even if the DIP switch is turned off.
1 2
DIP switch
Front case (back side)
No.
Switch state
Detail
OFF
ON
DIP
switch
1
Invalidity
Validity
Memory backup setting
* Set to ON to use batteries for
the memory backup.
,IEDWWHULHVDUHQRWXVHGWKH
settings information stored in
memory will be deleted if there
is a power failure.
2
Dual remote controller setting
* Refer to "6.1.2. Dual remote
controllers".
( Factory setting)
5.3.7 Attach the front case
,QVHUWDIWHUDGMXVWLQJXSSHUSDUWRIIURQWFDVH
:KHQLQVHUWWKHIURQWFDVHGRQRWSLQFKWKHFDEOH
Front case
Click!
PROHIBITED
GOOD
CAUTION
,QVHUWWKHIURQWFDVH¿UPO\,ILPSURSHUO\DWWDFKHGLWZLOOFDXVHWKHIURQW
case to fall off.