2-16
(1) Turn over the HHC.
(2) Lift the outer lid of the battery cover with a coin or similar object and release the lid from the
lower cover (see (a)).
(3) Take out the batteries and disconnect the cable from the connector.
(a)
(b)
Figure 2.7 Replacing the lithium back-up batteries (auxiliary batteries)
Note:
When disconnecting the cable, hold it by both connectors. Do not pull directly on the wire.
(4) Load new batteries by reversing the removal steps.
CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE
ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER.
DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.
ATTENTION: IL Y A DANGER D'EXPLOSION S'IL Y A REMPLACEMENT INCORRECT DE LA
BATTERIE. REMPLACER UNIQUEMENT A VEC UNE BATTERIE DU MÊME TYPE OU D'UN
TYPE RECOMMANDÉ PAR LE CONSTRUCTEUR. METTRE AU RÉBUT LES BATTERIES
USAGÉES CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT.
Lithium back-up battery