6. Build and connect your DC power cables into the server power supplies and into separate power sources. 

Instructions for building the DC power cables are in the 

SPARC Enterprise T5120 and T5220 Servers Installation 

Guide

.

To provide redundancy, plug both power supplies into separate power sources. Note that the system can 
operate with only one power connection, but there is no redundancy in this case.
When power is applied, the SP initializes and power supply LEDs illuminate. After a few minutes, the SP 
login prompt appears on the terminal device. Note that the host is not initialized or powered on yet.

7. At the terminal device, log in to the SP as 

root

 with a password of 

changeme

.

After a brief delay, the SP prompt is displayed (

->

). 

At this point, there are many commands you can perform using the Integrated Lights Out Manager interface. 
For example, to create a user named 

admin

, and to set the 

admin

 account role to 

Administrator

 and the 

CLI mode to 

alom

, enter:

Note that the asterisks in the example will not appear when you enter your password. 
In the future, when you log in to the 

admin

 account, you use the ALOM CMT compatibility command set. In 

the meantime, you are using the default ILOM command set.
Additional SP information, such as how to change the password and how to set up the SP network 
parameters, is available in the online documentation set. 

8. Power on the server and redirect the host output to display on the serial terminal device:

After you start the SP console, the server initialization takes approximately 20 minutes to complete.

9. When prompted, follow the onscreen instructions and enter the configuration information.

Refer to 

TABLE 1

 for the list of configuration information and your entries. You will be prompted to confirm 

the configuration several times, enabling confirmation and changes. If you are not sure how to respond to a 
particular value, you can accept the default, and make future changes when the Solaris OS is running.
When the configuration menus are completed, the server reboots and displays the Solaris login prompt. 

SUNSP00144FAC732F login: 

root

Password: 

changeme

. . . 

->

-> 

create /SP/users/admin role=Administrator cli_mode=alom

Creating user...

Enter new password: ********

Enter new password again: ********

Created /SP/users/admin 

-> 

start /SYS

Are you sure you want to start /SYS (y/n)? 

y

-> 

start /SP/console

Are you sure you want to start /SP/CONSOLE (y/n)? 

y

Serial console started. To stop, type #.

. . .

Summary of Contents for SPARC ENTERPRISE T5220

Page 1: ...o This system includes a service processor SP that is used to configure and boot the host server To properly configure the host server and view SP messages do not apply power to the server until the SP and host networking connections are made as described in this guide Choose the best instructions for your situation The quick setup instructions in this guide work for any networking environment and...

Page 2: ... select the first one in the list DHCP Select Yes or No according to your network environment Host Name Enter the host name for the server IP Address Enter the IP address for the selected Ethernet interfaces Subnet Select Yes or No according to your network environment Subnet Netmask If subnet was Yes Enter the netmask for the subnet for your network environment IPv6 Specify whether or not to use ...

Page 3: ...sing 9600 baud 8 bit no parity 1 stop bit A null modem configuration is needed meaning the transmit and receive signals are reversed crossed over for DTE to DTE communications You can use the supplied RJ 45 crossover adapters with a standard RJ 45 cable to achieve the null modem configuration FIGURE 2 Server Connections 4 Optional Connect an Ethernet cable between the server s NET MGT port FIGURE ...

Page 4: ...nt you use the ALOM CMT compatibility command set In the meantime you are using the default ILOM command set Additional SP information such as how to change the password and how to set up the SP network parameters is available in the online documentation set 8 Power on the server and redirect the host output to display on the serial terminal device After you start the SP console the server initial...

Page 5: ...r SPARC Enterprise Series Servers Before you deploy your server check for the Product Notes for your server and other important information on the following websites Global Site http www fujitsu com sparcenterprise manual notes North American Site https download computers us fujitsu com Japanese Site http primeserver fujitsu com sparcenterprise manual notes Accessing Documentation The following we...

Page 6: ...t the following URL For Users in U S A Canada and Mexico https download computers us fujitsu com For Users in Other Countries http www fujitsu com global contact computing sparce_index html Copyright 2008 2009 Sun Microsystems Inc All rights reserved FUJITSU LIMITED provided technical input and review on portions of this material Copyright 2008 2009 Sun Microsystems Inc Tous droits réservés Revue ...

Page 7: ......

Page 8: ... 䊌䊤 䊜 䊷 䉺 ജౝኈ GU Use the NFSv4 domain derived by the system ...

Page 9: ...root ...

Page 10: ...C732F login TQQV Password EJCPIGOG Creating user Enter new password Enter new password again Created SP users admin Are you sure you want to start SYS y n Are you sure you want to start SP CONSOLE y n Serial console started To stop type ...

Page 11: ...showrev a psrinfo ...

Page 12: ......

Reviews: