88
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
9. Repeat
through
until all new FB-DIMMs are installed.
10. (SPARC Enterprise T5140 servers) Reconnect the hard drive cable.
a. Route the hard drive data cable over the fan module and along the air duct.
b. Plug the data cable into J6401 on the motherboard.
11. Install the top cover.
See
“Install the Top Cover” on page 177
12. Slide the server into the rack.
See
“Return the Server to the Normal Rack Position” on page 180
.
13. Connect the power cords.
See
“Connect Power Cords to the Server” on page 181
Note –
As soon as the power cords are connected, standby power is applied.
Depending on how the firmware is configured, the system might boot at this time.
Related Information
■
■
“Verify Successful Replacement of Faulty FB-DIMMs” on page 88
▼
Verify Successful Replacement of Faulty
FB-DIMMs
1. Access the ILOM
->
prompt.
Refer to the
Integrated Lights Out Manager 3.0 (ILOM 3.0) Supplement for SPARC
Enterprise T5140 and T5240 Servers
for instructions.
2. Use the
show faulty
command to determine how to clear the fault.
■
If
show faulty
indicates a POST-detected the fault go to
.
■
If
show faulty
indicates a host-detected fault (output displays a UUID), go
directly to
Summary of Contents for SPARC Enterprise T5140
Page 1: ......
Page 2: ......
Page 6: ......
Page 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Page 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Page 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Page 239: ......
Page 240: ......