4
SPARC Enterprise T1000 Server Site Planning Guide • April 2007
Power Source Requirements
The SPARC Enterprise T1000 server has an autoranging power supply.
Acoustic Noise Emissions
Declared noise emissions are in accordance with ISO 9296 standards.
Agency Compliance Specifications
See the
SPARC Enterprise T1000 Server Safety and Compliance Guide
for a full list of
agency compliance specifications.
Description
Specification
Operating input voltage range
100 to 240 VAC, 50-60 Hz
(Input voltage tolerance
±
10%)
Maximum operating input current
2.2 A at 100 to 120 VAC
1.1 A at 200 to 240 VAC
Typical operating input power
Maximum operating input power
180 W
220 W
Typical heat dissipation
Maximum heat dissipation
614 BTU/hr. (647 KJ/hr)
750 BTU/hr. (791 KJ/hr)
Description
Mode
Specification
LwAd (1 B = 10 dB)
Operating acoustic noise
Idling acoustic noise
7.7 B
7.7 B
LpAm (bystander positions)
Operating acoustic noise
Idling acoustic noise
66 dB
66 dB