background image

Summary of Contents for SPARC ENTERPRISE T1000

Page 1: ......

Page 2: ......

Page 3: ...SPARC Enterprise T1000 Server Site Planning Guide Manual Code C120 H018 01EN Part No 875 4020 10 April 2007 ...

Page 4: ... and the Fujitsu logo are registered trademarks of Fujitsu Limited All SPARC trademarks are used under license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and ...

Page 5: ...Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems Inc SPARC64 est une marques déposée de SPARC International Inc utilisée sous le permis par Fujitsu Microelectronics Inc et F...

Page 6: ......

Page 7: ... Specifications 2 Minimum Clearance for Service Access 2 Environmental Specifications 3 Power Source Requirements 4 Acoustic Noise Emissions 4 Agency Compliance Specifications 4 General Site Preparation Notes 5 Ambient Temperature 5 Ambient Relative Humidity 5 Airflow Considerations 6 ...

Page 8: ...vi SPARC Enterprise T1000 Server Site Planning Guide April 2007 ...

Page 9: ...t information regarding the use and handling of this product Read this manual thoroughly Use the product according to the instructions and information available in this manual Keep this manual handy for further reference Fujitsu makes every effort to prevent users and bystanders from being injured or from suffering damage to their property Use the product according to this manual Related Documenta...

Page 10: ...er C120 E380 SPARC Enterprise T1000 Server Installation Guide Detailed rackmounting cabling power on and configuring information C120 E383 SPARC Enterprise T1000 Server Service Manual How to run diagnostics to troubleshoot the server and how to remove and replace parts in the server C120 E384 SPARC Enterprise T1000 Server System Administration Guide How to perform administrative tasks that are spe...

Page 11: ...Preface ix Fujitsu Welcomes Your Comments We would appreciate your comments and suggestions to improve this document You can submit your comments by using Reader s Comment Form ...

Page 12: ...x SPARC Enterprise T1000 Server Site Planning Guide April 2007 Reader s Comment Form ...

Page 13: ... MAIL FIRST CLASS MAIL PERMIT NO 741 SUNNYVALE CA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY ADDRESSEE FUJITSU COMPUTER SYSTEMS ATTENTION ENGINEERING OPS M S 249 1250 EAST ARQUES AVENUE P O BOX 3470 SUNNYVALE CA 94088 3470 ...

Page 14: ...xii SPARC Enterprise T1000 Server Site Planning Guide April 2007 ...

Page 15: ...ise T1000 Server Safety and Compliance Guide and the Important Safety Information for Hardware Systems document that came with your server This guide contains the following sections Physical Specifications on page 2 Minimum Clearance for Service Access on page 2 Environmental Specifications on page 3 Power Source Requirements on page 4 Acoustic Noise Emissions on page 4 Agency Compliance Specifica...

Page 16: ...e the minimum clearances needed for service Description U S Metric Width 16 8 in 425 mm Depth 18 4 in 467 mm Height 1 75 in 1 rack unit 43 mm Weight without PCI card and rackmounts 20 5 lb 9 3 kg Weight with slide rails 24 lb 10 9 kg Description Specification Clearance front of system 36 in 91 cm Clearance rear of system 36 in 91 cm ...

Page 17: ... to 60 C 40 to 60 C Humidity 20 to 80 RH non condensing 27 C wet bulb IEC 60068 2 3 56 98 RH 38 C non condensing IEC 60068 2 3 56 Altitude 0 3 000 meters 0 10 000 feet IEC 60068 2 13 0 12 000 meters 0 40 000 feet IEC 60068 2 13 Vibration 0 2 Gs Swept sine 5 500 5Hz 1 octave min all axes IEC 60068 2 13 1 0 Gs Swept sine 5 500 5Hz 1 octave min all axes IEC 60068 2 13 Shock 5 Gs peak 11 milliseconds ...

Page 18: ...ncy compliance specifications Description Specification Operating input voltage range 100 to 240 VAC 50 60 Hz Input voltage tolerance 10 Maximum operating input current 2 2 A at 100 to 120 VAC 1 1 A at 200 to 240 VAC Typical operating input power Maximum operating input power 180 W 220 W Typical heat dissipation Maximum heat dissipation 614 BTU hr 647 KJ hr 750 BTU hr 791 KJ hr Description Mode Sp...

Page 19: ...nmental Specifications on page 3 Operating computer equipment in extremes of temperature or humidity increases the failure rate of hardware components To minimize the chance of component failure use the server within the optimal temperature and humidity ranges Ambient Temperature An ambient temperature range of 69 8 F 21 C to 73 4 F 23 C is optimal for system reliability At 71 6 F 22 C it is easy ...

Page 20: ...her open area characteristics that are more restrictive should be evaluated by the user Allow a minimum of 0 2 in 5 mm clearance at the front of the system and 3 1 in 80 mm at the rear of the server when mounted These clearance values are based on the inlet and exhaust impedance available open area and assume a uniform distribution of the open area across the inlet and exhaust areas Clearance valu...