6-22
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
6.4
CPU Module and DIMM Replacement
The CPU module and DIMM are mounted on a CMU. This section describes the procedure
to replace the CPU module and DIMM.
■
Section 6.4.1, “Notes on CPU Module Replacement” on page 6-23
■
Section 6.4.2, “CPU Module Replacement” on page 6-25
■
Section 6.4.3, “Notes on DIMM Replacement” on page 6-34
■
Section 6.4.4, “DIMM Replacement” on page 6-37
When replacing a CPU module or DIMM, replace it with one of the same type. For details of
the mounting locations indicated in messages, see
.
FIGURE 6-12
CPU Module and DIMM (MEM) Mounting Locations
CPUM#3
CPUM#2
CPUM#1
CPUM#0
MEM#23B
MEM#23A
MEM#22B
MEM#22A
MEM#12A
MEM#12B
MEM#13A
MEM#13B
MEM#03B
MEM#03A
MEM#02B
MEM#02A
MEM#30A
MEM#30B
MEM#31A
MEM#31B
MEM#21B
MEM#21A
MEM#20B
MEM#20A
MEM#10A
MEM#10B
MEM#11A
MEM#11B
MEM#01B
MEM#01A
MEM#00B
MEM#00A
MEM#32B
MEM#32A
MEM#33A
MEM#33B
Front side
Summary of Contents for SPARC Enterprise M8000
Page 4: ......
Page 15: ...Contents xv Index Index 1 ...
Page 16: ...xvi SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 22: ......
Page 27: ...Chapter 1 Safety and Tools 1 5 M9000 Server Front View ...
Page 29: ...Chapter 1 Safety and Tools 1 7 Power Supply Unit PSU ...
Page 38: ...1 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 88: ...2 50 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 148: ......
Page 154: ...5 6 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 205: ...Chapter 7 I O Unit IOU Replacement 7 13 FIGURE 7 8 Removing the IOU Front of M9000 1 1 2 3 ...
Page 227: ...Chapter 8 FAN Unit Replacement 8 11 FIGURE 8 9 Removing the FAN Unit Rear of M8000 1 2 ...
Page 256: ...10 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 272: ...11 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 312: ...13 30 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 340: ...15 14 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 358: ...17 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 370: ...18 12 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 380: ...19 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 409: ...Chapter 20 Backplane Replacement 20 29 FIGURE 20 16 Removing the FANBP Rear of the M8000 ...
Page 422: ...21 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 439: ...Chapter 23 Switch Backplane Replacement 23 7 FIGURE 23 4 Removing the SWBP Rear of the M8000 ...
Page 442: ...23 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 460: ...24 18 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 484: ...25 24 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 494: ...A 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 544: ...C 4 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 552: ...D 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...