Chapter 5 Daily Care
55
Ultrasonic sensor (× 2)
Gently wipe dirt and dust off the surface of the ultrasonic sensors.
Feed roller (× 2)/Eject roller (× 2)
The power must be turned on to rotate the feed/eject rollers for cleaning.
1 Turn on the scanner.
For details, refer to
"1.3 Turning the Power ON/OFF" (page 16)
.
2 When the operator panel is in ready status, open the ADF.
For details, refer to
"1.4 Opening/Closing the ADF" (page 17)
.
3 When you press the scan/stop button on the operator panel for
more than 2 seconds, the feed/eject rollers rotate.
4 Put a piece of cloth moistened with Cleaner F1 or a sheet of
Cleaning Wipe against the roller surface, and wipe horizontally.
Wipe the whole surface by pressing the scan/stop button to rotate
the rollers.
Make sure that it is cleaned properly because residue on the roller
will affect the feeding performance.
HINT
If it is difficult to clean, use a cotton swab.
Ultrasonic sensor
When you press the scan/stop button, the
feed/eject rollers rotate at the same time.
Be careful not to touch the rollers with your
hand while they are rotating.
Scan/stop button
CAUTION