163
CHAPTER 2 DEPENDENCE FUNCTIONS
2.3.5
Control by Sequencer
This emulator has a sequencer to control events. By using this sequencer, sampling of
breaks or traces can be controlled while monitoring program flow (sequence). A break
caused by this function is called a sequential break.
■
Control by Sequencer
As shown in Table 2.3-4, controls can be made at 3 different levels.
One event can be set for one level.
The sequencer always moves from Level 1 through Level 2 to Level 3. One event can be specified as a
sequencer restart condition.
When the debug function on MB2147-01 is set to Trace Enhancement mode, it is possible to control a trace
by a sequencer.
1. Complete the trace acquisition.
2. Transit to the next block (Only in multi trace mode)
Table 2.3-4 Sequencer Specifications
Function Specifications
Level count
3 restart condition
Conditions settable for each level
1 event conditions (1 to 16777215 times pass count can be
specified for each condition.)
Restart conditions
1 event conditions (1 to 16777215 times pass count can be
specified.)
Operation when conditions established
Branching to another level or terminating sequencer
Summary of Contents for SOFTUNE F2 MC-16
Page 2: ......
Page 3: ...FUJITSU SEMICONDUCTOR LIMITED F2 MC 16 FAMILY SOFTUNETM Workbench USER S MANUAL ...
Page 4: ......
Page 8: ...iv ...
Page 14: ...x ...
Page 342: ...328 CHAPTER 2 DEPENDENCE FUNCTIONS ...
Page 343: ...329 INDEX INDEX The index follows on the next page This is listed in alphabetic order ...
Page 352: ...338 INDEX ...
Page 354: ......