![Fujitsu SOFTUNE F2 MC-16 User Manual Download Page 112](http://html.mh-extra.com/html/fujitsu/softune-f2-mc-16/softune-f2-mc-16_user-manual_118473112.webp)
98
CHAPTER 2 DEPENDENCE FUNCTIONS
[Setup Examples]
- Terminate sequencer when event 1 occurs.
>SET SEQUENCE/EVENT 1,1,J=0
- Terminate sequencer when event 2 occurs 16 times.
>SET SEQUENCE/EVENT 1,2,16,J=0
- Terminate sequencer when event 2 occurs after event 1 occurred. However, do not terminate sequencer
if event 3 occurs between event 1 and event 2.
>SET SEQUENCE/EVENT 1,1,J=2
>SET SEQUENCE/EVENT 2,2,J=0
>SET SEQUENCE/EVENT 2,3,J=1
- Terminate sequencer if and when event 2 occurs less than 300
μ
s after event 1 occurred.
>SET SEQUENCE/EVENT 1,1,J=2
>SET SEQUENCE/EVENT 2,2,J=0
>SET SEQUENCE/TIMER 2,300,J=1
>SHOW SEQUENCE
Sequencer Enable
level1 level2 level3 level4 level5 level6 level7 level8
1 |1|->2 | |
| | | |
| |
| |
| |
| |
2 | |
|2|->end | | | |
| |
| |
| |
| |
3 | |
| | | |
| |
| |
| |
| |
| |
4 | |
| | | |
| |
| |
| |
| |
| |
5 | |
| | | |
| |
| |
| |
| |
| |
6 | |
| | | |
| |
| |
| |
| |
| |
7 | |
| | | |
| |
| |
| |
| |
| |
8 | |
| | | |
| |
| |
| |
| |
| |
T | |
|T|->1
| | | |
| |
| |
| |
| |
Latch 1 ( -> ) =
Latch 2 ( -> ) =
>SHOW SEQUENCE 2
level no. = 2
event
pass-count
trace-cnt1
jmp-level1
2
1
enable
end
timer
00:00:000:300:000 enable
1
Indicates
move to level
2 when event
1 occurs at
level 1
Indicate s terminating
sequencer when event 2
occurs at level 2.
Indicates move to level 1 if and
when 300
μ
s passed before
event 2 occurs at level 2
Summary of Contents for SOFTUNE F2 MC-16
Page 2: ......
Page 3: ...FUJITSU SEMICONDUCTOR LIMITED F2 MC 16 FAMILY SOFTUNETM Workbench USER S MANUAL ...
Page 4: ......
Page 8: ...iv ...
Page 14: ...x ...
Page 342: ...328 CHAPTER 2 DEPENDENCE FUNCTIONS ...
Page 343: ...329 INDEX INDEX The index follows on the next page This is listed in alphabetic order ...
Page 352: ...338 INDEX ...
Page 354: ......