Important information
4.6
Notes on installing the server in the rack
V
CAUTION!
●
For safety reasons, at least two people are required to install the
server in the rack because of its weight and size.
(For the Japanese market, please refer to "
安全上のご注意
".)
●
Never lift the server into the rack using the QRLs (Quick Release
Levers) on the front panel.
●
When connecting and disconnecting cables, observe the relevant
instructions in the "Important Information" chapter of the technical
manual for the corresponding rack. The technical manual is supplied
with the corresponding rack.
●
When installing the rack, make sure that the anti-tilt mechanism is
correctly fitted.
●
Do not extend more than one unit out of the rack simultaneously even
if the tilt protection is in place. If several units are simultaneously
extended from the rack, there is a risk that the rack could tip over. See
the safety information of the rack and the warning label.
●
Only for the EMEA market:
The rack must be connected to the power supply by an authorized
specialist (electrician).
●
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 type connector, the
power supply's fuse protection must comply with the requirements for
non-industrial power supply networks for the type A connector.
Summary of Contents for Server PRIMERGY TX1330 M1
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY TX1330 M1 Operating Manual Edition July 2014 ...
Page 6: ...Operating Manual TX1330 M1 ...
Page 10: ...Operating Manual TX1330 M1 Contents ...
Page 14: ...14 Operating Manual TX1330 M1 Introduction ...
Page 58: ...58 Operating Manual TX1330 M1 Hardware installation ...
Page 80: ...80 Operating Manual TX1330 M1 Property and data protection ...