background image

 
 

Chapter 4

 

LinkAggregation Feature 

This chapter outlines the LinkAggregation feature, and explains the settings required to 

use this feature. 

●  About the LinkAggregation feature  
●  Configuration of the LinkAggregation feature  
●  Notes  

 

 
 

Summary of Contents for PW008GE4

Page 1: ...FUJITSU PCI GigabitEthernet 3 0 Update1 for Solaris TM Operating System User s Guide ...

Page 2: ...uld not be exported from Japan or transferred to anyone other than residents of Japan without first obtaining license from the Ministry of International Trade and Industry of Japan in accordance with the above law TRADEMARK ACKNOWLEDGMENTS FUJITSU and the FUJITSU logo are trademarks of Fujitsu Limited UNIX is a registered trademark of The Open Group in the United States and other countries Sun Sun...

Page 3: ...VLAN information is added Change the Version 2 0 to 2 1 03 2004 1 8 Appendix E VLAN tested switches are added Chapter 4 LinkAggregation function is added Change the Version 2 1 to 2 2 Appendix A Messages are added 04 2004 10 28 Appendix E Switches are added 05 2005 11 11 Change the Version 2 2 to 2 3 06 2006 02 06 Change the Version 2 3 to 2 4 07 2007 01 20 Change the Version 2 4 to 3 0 08 2007 04...

Page 4: ...ormation Chapter 3 provides an overview of the environment definition Chapter 4 LinkAggregation Feature Chapter 4 describes how to use the LinkAggregation function Chapter 5 Troubleshooting Chapter 5 offers suggestions about how to troubleshoot and resolve problems you might encounter during installation Appendix A Messages Appendix A shows the messages output by the driver software Appendix B On ...

Page 5: ...iv ...

Page 6: ...4 Discernment Of the GigabitEthernet Interface 39 3 4 1 Discernment Of the GigabitEthernet Interface on PRIMEPOWER or GP7000 family 39 3 4 2 Discernment Of the GigabitEthernet Interface on SPARC Enterprise 40 3 5 Network Installation 42 3 6 VLAN Interface Setup 45 3 6 1 IEEE 802 1Q TagVLAN Description 45 3 6 2 Setting Up the VLAN Interface 45 Chapter 4 LinkAggregation Feature 47 4 1 About LinkAggr...

Page 7: ...sing GigabitEthernet in a Cluster Environment 71 C 1 Cluster Environment Support 71 C 2 Cluster Environment Setup Procedure 71 C 3 Notes 72 Appendix D PCI Slot Number and Device Name 73 Appendix E Available Switches 107 vi ...

Page 8: ...Chapter 1 Product Outline The following topics are described in this chapter Key Features GigabitEthernet card Specifications ...

Page 9: ...000 Base T 4ports PW008QG1 SE0X7GQ1X JumboFrame function ndd 1M command provided by Solaris OS VLAN IEEE 802 3 TagVLAN LinkAggregation IEEE 802 3 except dynamic LACP protocol IPv4 IPv6 SNA FNA JumboFrame VLAN and LinkAggregation functions are supported after Solaris 8 OS JumboFrame Functionality Although the maximum frame size MTU of one Ethernet packet is 1514 bytes by using a JumboFrame function...

Page 10: ...i mode Fibre 62 5 125 micron SC Duplex 10 100 1000Base T PW008GE5 PW0G8GE2 PRIMEPOWER250 450 secondary LAN PW008QG1 Cat5e Cable Cat5 cable can also be used for 10 100Mbps Table 1 2 2 PCI Express GigabitEthernet Card Specification Item Compatibility Host Bus Interface PCI Express 1 0a SE0X7GD1X SE0X7GD2X PCI Express 1 1 SE0X7GQ1X Network Interface 1000Base SX 2ports SE0X7GD2X 10 100 1000Base T 2por...

Page 11: ...low twisted pair cable connection See the section Chapter 2 Installing FUJITSU PCI GigabitEthernet Card for detailed information LEDs PW008GE4 1000BASE SX has two LEDs 1000M LED ACT LED indicating transmission rate and activity PW0G8GE1 and SE0X7GD2X 1000BASE SX has two LEDs LINK LED ACT LED indicating transmission rate and activity PW008GE5 and PW0G8GE2 10 100 1000BASE T have four LEDs 1000M LED ...

Page 12: ...1 2 GigabitEthernet card Specifications Figure 1 1 1000Base SX PW008GE4 Figure 1 2 10 100 1000Base T PW008GE5 Figure 1 3 1000Base SX PW0G8GE1 Figure 1 4 10 100 1000Base T PW0G8GE2 5 ...

Page 13: ...Chapter 1 Product Outline Figure 1 5 1000Base SX 2ports SE0X7GD2X Figure 1 6 10 100 1000Base T 2ports SE0X7GD1X 6 ...

Page 14: ...1 2 GigabitEthernet card Specifications Figure 1 7 10 100 1000Base T 4ports PW0G8GE1 Figure 1 8 10 100 1000Base T 4ports SE0X7GQ1X 7 ...

Page 15: ......

Page 16: ...alling FUJITSU PCI GigabitEthernet Card This chapter describes the tasks necessary to install this card in the main unit Installation of the GigabitEthernet card Identifying the GigabitEthernet card Cable connection ...

Page 17: ... 2 1 Installation of the GigabitEthernet Card Insert the card in a PCI slot or a PCI Express slot on the main unit Please refer to the main unit s User s Manual for details about installing cards and specific PCI slot or PCI Express slot specifications 10 ...

Page 18: ...2 2 Identifying the GigabitEthernet Card 2 2 Identifying the GigabitEthernet Card The GigabitEthernet card can be identified by executing the boot r command at the OpenBoot prompt ok boot r 11 ...

Page 19: ...and SE0X7GD2X GigabitEthernet card to the network use an optical fiber cable To connect the PW008GE5 PW0G8GE2 PRIMEPOWR250 450 secondary LAN PW008QG1 SE0X7GD1X and SE0x7GQ1X GigabitEthernet card to the network use a CAT5E twisted pair cable Enhanced Category 5 Figure 2 3 1 PW008GE4 with Optical Fiber Cable 12 ...

Page 20: ...2 3 Cable Connection Figure 2 3 2 PW008GE5 with Twisted Pair Cat5E Cable 13 ...

Page 21: ...Chapter 2 Installing FUJITSU PCI GigabitEthernet Card Figure 2 3 3 PW0G8GE1 with Optical Fiber Cable 14 ...

Page 22: ...2 3 Cable Connection Figure 2 3 4 PW0G8GE2 with Twisted Pair Cat5E Cable 15 ...

Page 23: ...Chapter 2 Installing FUJITSU PCI GigabitEthernet Card Figure 2 3 5 SE0X7GD2X with Optical Fiber Cable 16 ...

Page 24: ...2 3 Cable Connection Figure 2 3 6 SE0X7GD1X with Twisted Pair Cat5E Cable 17 ...

Page 25: ...Chapter 2 Installing FUJITSU PCI GigabitEthernet Card Figure 2 3 7 PW008QG1 with Twisted Pair Cat5E Cable 18 ...

Page 26: ...2 3 Cable Connection Figure 2 3 8 SE0X7GQ1X with Twisted Pair Cat5E Cable 19 ...

Page 27: ......

Page 28: ...guration information after installing the FUJITSU PCI GigabitEthernet interface The following topics are covered in this chapter Driver Software Installation Environment Setting Operation Mode Setup Discernment of the GigabitEthernet interface Network Installation VLAN Interface Setup ...

Page 29: ...Installation To make use of the FUJITSU PCI GigabitEthernet interface Solaris OS version specific driver packages must be installed from the attached CD ROM See the document Installation Guide FUJITSU PCI GigabitEthernet 3 0 Update1 for the installation procedure 22 ...

Page 30: ...e for detailed information about instance number Note 2 See section 3 2 2 Hostname Definition for detailed information about defining the hostname Note 3 Please put in neither a blank nor a empty line behind an IP address If a blank or a empty line enter it will not be activated at the time of main part equipment starting 2 To use the GigabitEthernet interface as an IPv6 interface Allocate an IP a...

Page 31: ...Chapter 3 Setting Configuration Information Example etc hosts file IP Address Hostname 190 168 150 1 giga v4 24 ...

Page 32: ...tc inet ipnodes file Example etc inet ipnodes file IP Address Hostname fe80 2e0 ff fea6 2222 giga v6 3 2 3 Netmask Value Definition To use the GigabitEthernet interface as an IPv4 interface add the netmask value and IP address to the etc netmasks file Example etc netmasks file IP Address netmask 192 168 150 0 255 255 255 0 25 ...

Page 33: ... when you want to set speed as 100Mbps in order to press down the CPU load by the network low When JumboFrame is used It is also possible to set up except fjgi conf For details please refer to 3 3 2 JumboFrame Setup The following table provides descriptions of the parameters used in the fjgi conf file to configure the GigabitEthernet interface When editing the fjgi conf file please review the Caut...

Page 34: ... On Master Communication by Master Role_A 4 Slave Communication by Slave fjgi_mtu 5 1500 to 9000 MTU size is specified 1 When PW008GE5 or PW0G8GE2 is used it is possible to set name FJSV pgtb When PW008GE4 or PW0G8GE1 is used it is possible to set name FJSV pgsb It becomes the same meaning as having specified name fjgi in both cases 2 Parameter is supported on 10 100 1000Base T PW008GE5 PW0G8GE2 S...

Page 35: ...V p4ta 3 5 fjgi pci 83 4000 pci 3 FJSV p4ta 3 1 6 fjgi The unit address is the number to the right of FJSV pwga FJSV pgtb or FJSV pgsb The unit addresses from the example are shown below PRIMEPOWER250 450 secondary LAN port PW008GE5 PW0G8GE2 PW008GE4 PW0G8GE1 name fjgi fjgi fjgi parent pci 83 2000 pci 15 2000 pci 17 2000 unit address 1 1 1 PW008QG1 name fjgi parent pci 83 2000 pci 3 unit address i...

Page 36: ... partner equipment should also enable Auto Negotiation By doing so it is the optimal speed duplex flow control It is set up automatically When you use fjgi conf file and you change mode of operation please let mode of operation in agreement with self equipment and connection partner equipment When mode of operation is not in agreement with self equipment and connection partner equipment it may not...

Page 37: ...se set up by the method 2 1 Add the following line to etc system file set fjgi fjgi_jumbo 1 2 The MTU size of TCP IP is set up by describing MTU size in etc hostname fjgi notes in the form of the following between 1500 and 9000 and rebooting When not specifying an MTU value as this file it is set as a default value except for a 9000Byte MAC header Note expresses an instance number Setting formal h...

Page 38: ...an be used only in Solaris 9 or later and when the following patch for PRIMEPOWER is applied In the case of Solaris 9 OS 114994 13 or later In the case of Solaris 10 OS 120462 06 or later 1 Add fjgi_mtu parameter to fjgi conf file Specify the value like fjgi_mtu 8000 instead of the character string like fjgi_mtu 8000 Example of file description when setting MTU size of a specific interface to 8000...

Page 39: ...uto Negotiation from the equipment which does not support Auto Negotiation conversely The following examples show how to display and set the parameters using the ndd command Setup of an instance number ndd set dev fjgi instance value Instance number value of an applicable interface is specified example fjgi2 is specified ndd set dev fjgi instance 2 Note carry out for referring to carry out for set...

Page 40: ...p 0 ndd set dev fjgi adv_autoneg_cap 1 Note Please perform change and sending back of Auto Negotiation at the end When setting change is reflected an Auto Negotiation value being subject to change ndd set dev fjgi instance value Instance number value of an applicable interface is specified ndd set dev fjgi param1 value Change 1 of a setup ndd set dev fjgi param2 value Change 2 of a setup ndd set d...

Page 41: ...ead and write 10Mbps FullDuplex Setting 0 Invalid 1 Valid Default adv_10hdx_cap Read and write 10Mbps HalfDuplex Setting 0 Invalid 1 Valid Default adv_100fdx_cap Read and write 100Mbps FullDuplex Setting 0 Invalid 1 Valid Default adv_100hdx_cap Read and write 100Mbps HalfDuplex Setting 0 Invalid 1 Valid Default adv_1000fdx_cap Read and write 1000Mbps FullDuplex Setting 0 Invalid 1 Valid Default ad...

Page 42: ...artner has been set to 1000Mbps HalfDuplex by Auto Negotiation 0 Invalid 1 Valid lp_pauseTX Read only The link partner has been set to transmit pause frame by Auto Negotiation 0 Invalid 1 Valid lp_pauseRX Read only The link partner has been set to receive pause frame by Auto Negotiation 0 Invalid 1 Valid lp_autoneg_cap Read only The link partner has been set to Auto Negotiate by Auto Negotiation 0...

Page 43: ...arameter values set by the ndd command become invalid after reboot An ndd command made to a physical interface that is related to IPv4 IPv6 interface and SNA FNA interface will apply to both the physical interface and the VLAN interface 3 3 4 FCode Settings By modifying FCode settings the adapter communication mode can be changed Changing the FCode settings is possible on PW008GE4 PW0G8GE1 SE0X7GD...

Page 44: ...GD1X PW008QG1 SE0X7GQ1X and PRIMEPOWER250 450 secondary LAN port is as follows Execute the following command to set Full Duplex communication 100Mbps example ok transfer speed 100 Execute the following command to set Half Duplex communication 100Mbps example ok transfer speed 100 example ok half duplex Execute the following command to set Full Duplex communication 10bps example ok transfer speed 1...

Page 45: ...0000000 00010000 model Broadcom BCM5703C compatible fjgi name FJSV pgtb media type 1000BASE T fcode rom offset 00000000 66mhz capable fast back to back devsel speed 00000001 class code 00020000 interrupts 00000001 max latency 00000000 min grant 00000040 subsystem id 000011a1 subsystem vendor id 000010cf revision id 00000002 device id 000011a1 vendor id 000010cf pcibus name PCIBUS G component name ...

Page 46: ...FJSV p4ta instance 3 driver name fjgi FJSV p4ta instance 4 driver name fjgi FJSV p4ta instance 5 driver name fjgi FJSV p4ta instance 6 driver name fjgi The instance number is the number displayed in bold above The adapter type can also be determined from the prtconf command output FJSV pwga PRIMEPOWER250 450 secondary LAN port FJSV pgsb PW008GE4 PW0G8GE1 1000BASE SX card FJSV pgtb PW008GE5 PW0G8GE...

Page 47: ...hernet interface instance number interface type and which slot the card is installed in on SPARC Enterprise 1 To determine the instance number execute the following command prtconf D grep fjgi example prtconf D grep fjgi FJSV e4ta instance 0 driver name fjgi FJSV e4ta instance 1 driver name fjgi FJSV e4ta instance 2 driver name fjgi FJSV e4ta instance 3 driver name fjgi FJSV e2sa instance 4 driver...

Page 48: ...are displayed The following table shows the logical bus address instance number and driver name for the example output above Logical bus address Instance number Driver name pci 1 700000 pci 0 FJSV e4ta 4 0 fjgi pci 1 700000 pci 0 FJSV e4ta 4 1 1 fjgi pci 1 700000 pci 0 1 FJSV e4ta 6 2 fjgi pci 1 700000 pci 0 1 FJSV e4ta 6 1 3 fjgi pci 3 700000 pci 0 FJSV e2sa 4 4 fjgi pci 3 700000 pci 0 FJSV e2sa ...

Page 49: ...is netinstall Solaris_8 Tools Boot on the installation server CLIENT_NAME is the name of the client system SERVER_NAME is the name of the installation server If the mini root directory name is not described in the etc bootparams file please refer to the Advanced Installation Guide 3 Insert the FUJITSU PCI GigabitEthernet 3 0 Update1 CD ROM into the CD ROM drive of the installation server 4 Install...

Page 50: ...to the install image in the install server Solaris 8 OS 114536 12 or later Solaris 9 OS 114994 12 or later Solaris 10 OS 120462 05 or later cd cdrom cdrom0 FJSVgid_3 0 Solaris level of client system patchadd C mini_root_directory Patch ID cd 5 Eject the FUJITSU PCI GigabitEthernet 3 0 Update1 CD ROM from the CD ROM drive 6 Shutdown the OS on the client system and confirm that the OpenBoot ok promp...

Page 51: ...d system FJSVgid Fujitsu Gigabit Interface Adapter system FJSVgidx Fujitsu Gigabit Interface Adapter 64 bit If the software has not been installed install the FUJITSU PCI GigabitEthernet software from the CD ROM that came with the adapter Refer to the Installation Guide FUJITSU PCI GigabitEthernet 3 0 Update1 for more information about installation When you install Solaris 2 6 OS via a network ple...

Page 52: ...cal interface is not allowed The following example shows a VLAN environment By using a VLAN traffic management of two or more networks on a single physical interface can be done In order to create a VLAN environment a switch capable of supporting a VLAN setup VID and Tagged Untagged setting is required The numbers FUJITSU PCI GigabitEthernet 3 0 adapter supports VID 1 4094 are available Max number...

Page 53: ...on the VLANs setup on the server Use the VLAN interface only with the TCP IP protocol Do not use the VLAN interface with SNA FNA or OSI protocol SafeLINK and PRIMECLUSTER GLS 4 1A20 or earlier do not support the VLAN function PRIMECLUSTER GLS 4 1A30 or later in fast switching or NIC switching mode does support the VLAN function The VLAN function is supported with Solaris 8 OS or later In a PRIMECL...

Page 54: ...inkAggregation Feature This chapter outlines the LinkAggregation feature and explains the settings required to use this feature About the LinkAggregation feature Configuration of the LinkAggregation feature Notes ...

Page 55: ...rted 1 As long as there is at least one transmission path available communication can be continued 2 The interface which can be made a group by FUJITSU PCI GigabitEthernet is only a fjgi interface Requirements Table 4 1 1 shows requirements for the LinkAggregation feature Table 4 1 1 Requirements OS Solaris 8 OS or later 64bit environment FJSVla package included in PRIMECLUSTER GLS 4 1 A30 or late...

Page 56: ...LinkAggregation function determines the transmission path to be used from the destination IP address in the outgoing packet This reduces the likelihood of only specific transmission paths being used if the system mainly communicates with remote systems on different networks via a router and improves transfer efficiency Source Destination IP address distribution The LinkAggregation function determi...

Page 57: ...a package Copy the sample file to create the config file cp etc opt FJSVla config sample etc opt FJSVla config 2 Modifying the etc opt FJSVla config file The following parameters must be specified in the etc opt FJSVla config file to use the LinkAggregation feature aggregator interface Specify the physical interface that represents the LinkAggregation group The froup is a unit that performs data d...

Page 58: ...on setup sample file attension Don t use the different link_speed interfaces in same group and can t use half duplex interface in LinkAggregation member_instance Input the number of interface The available members are max 7 Please don t include the aggregator_interface number mode 1 Mac Hash 2 Destination Address 3 Source and Destination Address format aggregator_interface member_instance member_i...

Page 59: ...Vla bin fjla init aggregator interface member instance member instance distribution mode aggregator interface Aggregator interface name including instance number member instance Instance numbers of member interfaces distribution mode Distribution mode used by the LinkAggregation group One of the following values must be specified 1 Destination MAC address distribution 2 Destination IP address dist...

Page 60: ...specified as a member instance Configuration by the fjla init command will become ineffective after system reboot Use the etc opt FJSVla config file for permanent configuration 4 2 2 2 Inactivate a LinkAggregation Group fjla term This section explains the fjla term command for inactivating a LinkAggregation group Synopsis etc opt FJSVla bin fjla term aggregator interface aggregator interface Aggre...

Page 61: ...or displaying the LinkAggregation status and statistic Synopsis etc opt FJSVla bin fjla stat aggregator interface i interval aggregator interface Aggregator interface name including instance number i interval s Specify the display interval in seconds maximum 4294967295 The command displays the statistics during the specified period However the first report shows statistics accumulated since the gr...

Page 62: ...p 0 0 0 0 0 0 Oct 05 17 20 14 2004 date and time Aggregator aggregator interface name Mode MH Destination MAC address distribution DA Destination IP address distribution DSA Source Destination IP address distribution Name Interface name Status up The interface is up and communicating down The interface is down or Link is down Ipkts The number of input packets Ierrs The number of input error packet...

Page 63: ... the fjla command The link speed must be the same among the member interfaces in a LinkAggregation group and duplex mode must be set to full It is necessary to inactivate the corresponding LinkAggregation group with the fjla term command before DR Dynamic Reconfiguration or PCI Hot Plug is performed It is necessary to activate corresponding LinkAggregation group with the fjla init command after DR...

Page 64: ...Boot PROM on the system is not recognizing the GigabitEthernet interface properly Check whether the interface is properly installed on the system Are the LEDs on the GigabitEthernet card working properly Check the following items if the LEDs indicate the link status is abnormal See also Appendix B On Board Diagnostics for detailed information Check Item Recommended Action Optical fiber cable Repla...

Page 65: ......

Page 66: ... 100 Transmitting and receiving data at 100Mbps 10 Transmitting and receiving data at 10Mbps B yes Auto Negotiation is on no Auto Negotiation is off C full Transmitting and receiving data in full duplex mode half Transmitting and receiving data in half duplex mode 2 network connection up using portA speed A autonegotiation B duplex mode C flowctrl D role E 1 D symmetric Send accept Flowcontrol req...

Page 67: ...was found in message fragmentation Re activate the interface If this message is still displayed report to your service provider 8 Could not allocate DMA handle The driver could not allocate DMA resources 9 Could not bind descriptor memory The driver could not allocate DMA resources Installed physical memory may be insufficient If this is not the cause report this error to your service provider 10 ...

Page 68: ... The driver could not allocate resources for the ndd parameter 24 fjgi_board_alloc_mem failed The driver could not allocate resources 25 Error filling TX ring The driver could not allocate transmit resources 26 status block can t alloced 27 status block can t alloced handle 28 status block can t bind handle The driver could not allocate status information resources 29 fjgi_board_init_mem Failed to...

Page 69: ...ember is wrong Abnormal response was returned to the fjla stat command The internal group table may be corrupt Please report this error to your service provider 44 Other messages There is a possibility of driver internal bug or hardware failure Report the error to your service provider 1 This appears only when PW008GE5 PW0G8GE2 SE0X7GD1X PW008QG1 SE0X7GQ1X or PRIMEPOWER250 450 secondary LAN port i...

Page 70: ...gregation now start LinkAggregation has been started normally There is no problem 3 fjla init XX does not support FJ LinkAggregation The interface XX doesn t support the LinkAggregation feature If the interface is fjgi check the patch level of the driver 4 fjla init XX vlan interface cannot define FJ LinkAggregation VLAN interface XX can not be used for the LinkAggregation feature By setting up th...

Page 71: ...la or does not exist Specified interface is already being used by other LinkAggregation group or it does not exist This message is also displayed when the command is executed by general users Specify interfaces that are not in the other LinkAggregation group Also specify interfaces that exist on the system 11 FJ LinkAggregation stop LinkAggregation has been stopped normally There is no problem 12 ...

Page 72: ... to a 1000Mbps network and is in the state which can communicate Off The adapter is not connected to a 1000Mbps network 100M LED indicates the following operation status PW008GE5 only 100M LED Description Green lighting The adapter is connected to a 100Mbps network and is in the state which can communicate Off The adapter is not connected to a 100Mbps network 10M LED indicates the following operat...

Page 73: ...3 1000Base SX PW0G8GE1 Figure B 4 1000Base SX 2ports SE0X7GD2X Meaning of the LEDs PW0G8GE1 SE0X7GD2X LINK LED indicates the following operation status LINK LED Description Green lighting The adapter is connected to a 1000Mbps network and is in the state which can communicate Off The adapter is not connected to a 1000Mbps network ACT LED indicates the following operation status ACT LED Description...

Page 74: ... following operation status 100M LED Description Green lighting The adapter is connected to a 100Mbps network and is in the state which can communicate Off The adapter is not connected to a 100Mbps network 10M LED indicates the following operation status 10M LED Description Green lighting The adapter is connected to a 10Mbps network and is in the state which can communicate Off The adapter is not ...

Page 75: ...network 100M LED indicates the following operation status 100M LED Description Green lighting The adapter is connected to a 100Mbps network and is in the state which can communicate Off The adapter is not connected to a 100Mbps network LINK ACT LED indicates the following operation status LINK ACT LED Description Green lighting The adapter is connected to a 1000Mbps 100Mbps or 10Mbps network and i...

Page 76: ... adapter is connected to a 1000Mbps network and is in the state which can communicate Green lighting The adapter is connected to a 100Mbps network and is in the state which can communicate Off The adapter is connected to a 10Mbps network and is in the state which can communicate or the adapter is not connected to a network ACT LED Green LED in Figure B 7 8 indicates the following operation status ...

Page 77: ......

Page 78: ...ize from a default value 9000 please set up by the fjgi conf file For details please refer to Method 3 How to specify by fjgi conf of 3 3 2 JumboFrame Setup The following table shows the supported failover mode with the FUJITSU PCI GigabitEthernet interfaces in a cluster system SynfinityCluster Failover Mode Support Status IP address Supported MAC address Supported IP address MAC address Supported...

Page 79: ...gabitEthernet cannot be used as the private LAN or for IP address fail over on a public LAN When using a FUJITSU PCI GigabitEthernet interface as a SynfinityCluster private LAN or as the PRIMECLUSTER cluster interconnect execute the following command before setting up the cluster example fjgi0 ifconfig fjgi0 plumb A FUJITSU PCI GigabitEthernet interface used as a VLAN interface cannot be used for ...

Page 80: ...PRIMEPOWER 450 pedestal 7U rack mount PRIMEPOWER 450 4U rack mount PRIMEPOWER 600 pedestal rackmount PRIMEPOWER 650 rackmount PRIMEPOWER 800 pedestal PRIMEPOWER 850 rackmount PRIMEPOWER 900 Physical Partitioning PRIMEPOWER 900 Extended Partitioning PRIMEPOWER 1000 GP7000F Model1000 PRIMEPOWER 1500 Physical Partitioning PRIMEPOWER 1500 Extended Partitioning PRIMEPOWER 2000 GP7000F Model2000 PRIMEPO...

Page 81: ...2000 1 01 PCI 2 pci 14 2000 1 01 PCI 3 pci 15 4000 2 01 PCI 4 pci 14 4000 2 01 PCI 5 pci 14 4000 4 01 PCI 6 pci 14 4000 5 GP7000F Model400 Slot Number Device Name PCI 1 pci 1f 2000 1 PCI 2 pci 1e 4000 2 PCI 3 pci 1e 4000 3 PCI 4 pci 1e 4000 4 PCI 5 pci 1e 2000 1 PCI 6 pci 1d 4000 2 PCI 7 pci 1d 4000 3 PCI 8 pci 1d 4000 4 PCI 9 pci 1d 2000 1 GP7000F Model600 Slot Number Device Name PCI 1 pci 1f 200...

Page 82: ...2000 1 PCI 12 pci 1e 2000 1 PRIMEPOWER 1 1U rackmount Slot Number Device Name PCI 1 pci 1f 0 pci 1 2 PRIMEPOWER 100 pedestal Slot Number Device Name PCI 1 pci 1f 0 pci 1 2 PCI 2 pci 1f 0 pci 1 3 PCI 3 pci 1f 0 pci 1 1 4 PRIMEPOWER 200 pedestal rackmount Slot Number Device Name PCI 1 pci 17 2000 1 PCI 2 pci 16 2000 1 PCI 3 pci 17 4000 2 PCI 4 pci 16 4000 2 PCI 5 pci 16 4000 4 PCI 6 pci 16 4000 5 PR...

Page 83: ...CI 3 pci 15 4000 4 PCI 4 pci 17 2000 1 PCI 5 pci 15 4000 5 PCI 6 pci 17 4000 2 PRIMEPOWER 400 pedestal 10U rackmount Slot Number Device Name PCI 1 pci 16 4000 5 PCI 2 pci 16 4000 4 PCI 3 pci 16 4000 2 PCI 4 pci 15 2000 1 PCI 5 pci 16 2000 1 PCI 6 pci 17 2000 1 PCI 7 pci 15 4000 5 PCI 8 pci 15 4000 4 PCI 9 pci 15 4000 2 PCI 10 pci 17 4000 2 PRIMEPOWER 400 PP040BR1U pedestal 10U rackmount Slot Numbe...

Page 84: ...i 83 4000 3 PRIMEPOWER 450 4U rack mount Slot Number Device Name PCI 0 pci 80 2000 1 PCI 1 pci 80 2000 2 PCI 2 pci 80 4000 3 PCI 3 pci 80 4000 4 PCI 4 pci 80 4000 5 PCI 5 pci 83 4000 3 PRIMEPOWER 600 pedestal rackmount Slot Number Device Name 00 PCI 1 pci 15 2000 1 00 PCI 2 pci 17 2000 1 00 PCI 3 pci 15 4000 2 00 PCI 4 pci 15 4000 4 00 PCI 5 pci 15 4000 5 00 PCI 6 pci 17 4000 2 01 PCI 1 pci 11 200...

Page 85: ...9 pci 82 4000 1 PCI 10 pci 82 4000 2 PCI BOX 0 PCI 11 pci 82 4000 3 PRIMEPOWER 800 pedestal Board Number Slot Number Device Name PCI 0A pci 80 2000 1 PCI 0B pci 80 4000 2 PCI 1A pci 81 2000 1 PCI 1B pci 81 4000 2 PCI 3A pci 83 2000 1 SB 0 PCI 3B pci 83 4000 2 PCI 0A pci 88 2000 1 PCI 0B pci 88 4000 2 PCI 1A pci 89 2000 1 PCI 1B pci 89 4000 2 PCI 3A pci 8b 2000 1 SB 1 PCI 3B pci 8b 4000 2 PCI 0A pc...

Page 86: ...PCI 5 pci 81 4000 1 PCI 6 pci 81 4000 2 PCI 7 pci 81 4000 3 PCI 8 pci 82 2000 1 PCI 9 pci 82 4000 1 PCI 10 pci 82 4000 2 PCI BOX 0 PCI 11 pci 82 4000 3 PCI 0 pci 8c 2000 1 PCI 1 pci 8c 4000 1 PCI 2 pci 8c 4000 2 PCI 3 pci 8c 4000 3 PCI 4 pci 8d 2000 1 PCI 5 pci 8d 4000 1 PCI 6 pci 8d 4000 2 SB 1 PCI 7 pci 8d 4000 3 PCI 0 pci 88 2000 1 PCI 1 pci 88 4000 1 PCI 2 pci 88 4000 2 PCI 3 pci 88 4000 3 PCI...

Page 87: ... connected to SB 0 PCI 9 pci 86 4000 3 PCI 0 pci 88 2000 1 PCI 1 pci 88 4000 2 PCI 2 pci 89 2000 1 PCI 3 pci 89 4000 2 PCI 4 pci 89 4000 3 PCI 5 pci 8a 2000 1 PCI 6 pci 8a 4000 2 SB 1 PCI 7 pci 8a 4000 3 PCI 0 pci 8c 2000 1 PCI 1 pci 8c 4000 2 PCI 2 pci 8c 4000 3 PCI 3 pci 8d 2000 1 PCI 4 pci 8d 4000 2 PCI 5 pci 8d 4000 3 PCI 6 pci 8d 4000 4 PCI 7 pci 8e 2000 1 PCI 8 pci 8e 4000 2 PCI BOX 0 connec...

Page 88: ... aa 2000 1 PCI 6 pci aa 4000 2 SB 1 PCI 7 pci aa 4000 3 PCI 0 pci cc 2000 1 PCI 1 pci cc 4000 2 PCI 2 pci cc 4000 3 PCI 3 pci cd 2000 1 PCI 4 pci cd 4000 2 PCI 5 pci cd 4000 3 PCI 6 pci cd 4000 4 PCI 7 pci ee 2000 1 PCI 8 pci ee 4000 2 PCI BOX 0 connected to SB 1 PCI 9 pci ee 4000 3 PRIMEPOWER 1000 GP7000F Model1000 Board Number Slot Number Device Name PCI 0A pci 80 2000 1 PCI 0B pci 80 4000 2 PCI...

Page 89: ...CI 3B pci a3 4000 2 PCI 0A pci a8 2000 1 PCI 0B pci a8 4000 2 PCI 1A pci a9 2000 1 PCI 1B pci a9 4000 2 PCI 3A pci ab 2000 1 SB 5 PCI 3B pci ab 4000 2 PCI 0A pci b0 2000 1 PCI 0B pci b0 4000 2 PCI 1A pci b1 2000 1 PCI 1B pci b1 4000 2 PCI 3A pci b3 2000 1 SB 6 PCI 3B pci b3 4000 2 PCI 0A pci b8 2000 1 PCI 0B pci b8 4000 2 PCI 1A pci b9 2000 1 PCI 1B pci b9 4000 2 PCI 3A pci bb 2000 1 SB 7 PCI 3B p...

Page 90: ... SB 1 PCI 7 pci 8a 4000 3 PCI 0 pci 8c 2000 1 PCI 1 pci 8c 4000 2 PCI 2 pci 8c 4000 3 PCI 3 pci 8d 2000 1 PCI 4 pci 8d 4000 2 PCI 5 pci 8d 4000 3 PCI 6 pci 8d 4000 4 PCI 7 pci 8e 2000 1 PCI 8 pci 8e 4000 2 PCI BOX 0 connected to SB 1 PCI 9 pci 8e 4000 3 PCI 0 pci 90 2000 1 PCI 1 pci 90 4000 2 PCI 2 pci 91 2000 1 PCI 3 pci 91 4000 2 PCI 4 pci 91 4000 3 PCI 5 pci 92 2000 1 PCI 6 pci 92 4000 2 SB 2 P...

Page 91: ...PCI 9 pci 9e 4000 3 PRIMEPOWER 1500 Extended Partitioning Board Number Slot Number Device Name PCI 0 pci 80 2000 1 PCI 1 pci 80 4000 2 PCI 2 pci 81 2000 1 PCI 3 pci 81 4000 2 PCI 4 pci 81 4000 3 PCI 5 pci a2 2000 1 PCI 6 pci a2 4000 2 SB 0 PCI 7 pci a2 4000 3 PCI 0 pci c4 2000 1 PCI 1 pci c4 4000 2 PCI 2 pci c4 4000 3 PCI 3 pci c5 2000 1 PCI 4 pci c5 4000 2 PCI 5 pci c5 4000 3 PCI 6 pci c5 4000 4 ...

Page 92: ... SB 2 PCI 7 pci b2 4000 3 PCI 0 pci d4 2000 1 PCI 1 pci d4 4000 2 PCI 2 pci d4 4000 3 PCI 3 pci d5 2000 1 PCI 4 pci d5 4000 2 PCI 5 pci d5 4000 3 PCI 6 pci d5 4000 4 PCI 7 pci f6 2000 1 PCI 8 pci f6 4000 2 PCI BOX 0 connected to SB 2 PCI 9 pci f6 4000 3 PCI 0 pci 98 2000 1 PCI 1 pci 98 4000 2 PCI 2 pci 99 2000 1 PCI 3 pci 99 4000 2 PCI 4 pci 99 4000 3 PCI 5 pci ba 2000 1 PCI 6 pci ba 4000 2 SB 3 P...

Page 93: ...SB 2 PCI 3B pci 8b 4000 2 PCI 0A pci 8c 2000 1 PCI 0B pci 8c 4000 2 PCI 1A pci 8d 2000 1 PCI 1B pci 8d 4000 2 PCI 3A pci 8f 2000 1 SB 3 PCI 3B pci 8f 4000 2 PCI 0A pci 90 2000 1 PCI 0B pci 90 4000 2 PCI 1A pci 91 2000 1 PCI 1B pci 91 4000 2 PCI 3A pci 93 2000 1 SB 4 PCI 3B pci 93 4000 2 PCI 0A pci 94 2000 1 PCI 0B pci 94 4000 2 PCI 1A pci 95 2000 1 PCI 1B pci 95 4000 2 PCI 3A pci 97 2000 1 SB 5 PC...

Page 94: ...4000 2 PCI 0A pci ac 2000 1 PCI 0B pci ac 4000 2 PCI 1A pci ad 2000 1 PCI 1B pci ad 4000 2 PCI 3A pci af 2000 1 SB 11 PCI 3B pci af 4000 2 PCI 0A pci b0 2000 1 PCI 0B pci b0 4000 2 PCI 1A pci b1 2000 1 PCI 1B pci b1 4000 2 PCI 3A pci b3 2000 1 SB 12 PCI 3B pci b3 4000 2 PCI 0A pci b4 2000 1 PCI 0B pci b4 4000 2 PCI 1A pci b5 2000 1 PCI 1B pci b5 4000 2 PCI 3A pci b7 2000 1 SB 13 PCI 3B pci b7 4000...

Page 95: ... 4000 2 PCI 0A pci cc 2000 1 PCI 0B pci cc 4000 2 PCI 1A pci cd 2000 1 PCI 1B pci cd 4000 2 PCI 3A pci cf 2000 1 SB 19 PCI 3B pci cf 4000 2 PCI 0A pci d0 2000 1 PCI 0B pci d0 4000 2 PCI 1A pci d1 2000 1 PCI 1B pci d1 4000 2 PCI 3A pci d3 2000 1 SB 20 PCI 3B pci d3 4000 2 PCI 0A pci d4 2000 1 PCI 0B pci d4 4000 2 PCI 1A pci d5 2000 1 PCI 1B pci d5 4000 2 PCI 3A pci d7 2000 1 SB 21 PCI 3B pci d7 400...

Page 96: ... 4000 2 PCI 0A pci ec 2000 1 PCI 0B pci ec 4000 2 PCI 1A pci ed 2000 1 PCI 1B pci ed 4000 2 PCI 3A pci ef 2000 1 SB 27 PCI 3B pci ef 4000 2 PCI 0A pci f0 2000 1 PCI 0B pci f0 4000 2 PCI 1A pci f1 2000 1 PCI 1B pci f1 4000 2 PCI 3A pci f3 2000 1 SB 28 PCI 3B pci f3 4000 2 PCI 0A pci f4 2000 1 PCI 0B pci f4 4000 2 PCI 1A pci f5 2000 1 PCI 1B pci f5 4000 2 PCI 3A pci f7 2000 1 SB 29 PCI 3B pci f7 400...

Page 97: ... pci 85 2000 1 PCI 4 pci 85 4000 2 PCI 5 pci 85 4000 3 PCI 6 pci 85 4000 4 PCI 7 pci 86 2000 1 PCI 8 pci 86 4000 2 PCI BOX 1 connected to SB 0 PCI 9 pci 86 4000 3 PCI 0 pci 88 2000 1 PCI 1 pci 88 4000 2 PCI 2 pci 88 4000 3 PCI 3 pci 89 2000 1 PCI 4 pci 89 4000 2 PCI 5 pci 89 4000 3 PCI 6 pci 89 4000 4 PCI 7 pci 8a 2000 1 PCI 8 pci 8a 4000 2 PCI BOX 0 connected to SB 1 PCI 9 pci 8a 4000 3 PCI 0 pci...

Page 98: ...i 95 4000 2 PCI 5 pci 95 4000 3 PCI 6 pci 95 4000 4 PCI 7 pci 96 2000 1 PCI 8 pci 96 4000 2 PCI BOX 1 connected to SB 2 PCI 9 pci 96 4000 3 PCI 0 pci 98 2000 1 PCI 1 pci 98 4000 2 PCI 2 pci 98 4000 3 PCI 3 pci 99 2000 1 PCI 4 pci 99 4000 2 PCI 5 pci 99 4000 3 PCI 6 pci 99 4000 4 PCI 7 pci 9a 2000 1 PCI 8 pci 9a 4000 2 PCI BOX 0 connected to SB 3 PCI 9 pci 9a 4000 3 PCI 0 pci 9c 2000 1 PCI 1 pci 9c...

Page 99: ...i a5 4000 2 PCI 5 pci a5 4000 3 PCI 6 pci a5 4000 4 PCI 7 pci a6 2000 1 PCI 8 pci a6 4000 2 PCI BOX 1 connected to SB 4 PCI 9 pci a6 4000 3 PCI 0 pci a8 2000 1 PCI 1 pci a8 4000 2 PCI 2 pci a8 4000 3 PCI 3 pci a9 2000 1 PCI 4 pci a9 4000 2 PCI 5 pci a9 4000 3 PCI 6 pci a9 4000 4 PCI 7 pci aa 2000 1 PCI 8 pci aa 4000 2 PCI BOX 0 connected to SB 5 PCI 9 pci aa 4000 3 PCI 0 pci ac 2000 1 PCI 1 pci ac...

Page 100: ...i b5 4000 2 PCI 5 pci b5 4000 3 PCI 6 pci b5 4000 4 PCI 7 pci b6 2000 1 PCI 8 pci b6 4000 2 PCI BOX 1 connected to SB 6 PCI 9 pci b6 4000 3 PCI 0 pci b8 2000 1 PCI 1 pci b8 4000 2 PCI 2 pci b8 4000 3 PCI 3 pci b9 2000 1 PCI 4 pci b9 4000 2 PCI 5 pci b9 4000 3 PCI 6 pci b9 4000 4 PCI 7 pci ba 2000 1 PCI 8 pci ba 4000 2 PCI BOX 0 connected to SB 7 PCI 9 pci ba 4000 3 PCI 0 pci bc 2000 1 PCI 1 pci bc...

Page 101: ...i c5 4000 2 PCI 5 pci c5 4000 3 PCI 6 pci c5 4000 4 PCI 7 pci c6 2000 1 PCI 8 pci c6 4000 2 PCI BOX 1 connected to SB 8 PCI 9 pci c6 4000 3 PCI 0 pci c8 2000 1 PCI 1 pci c8 4000 2 PCI 2 pci c8 4000 3 PCI 3 pci c9 2000 1 PCI 4 pci c9 4000 2 PCI 5 pci c9 4000 3 PCI 6 pci c9 4000 4 PCI 7 pci ca 2000 1 PCI 8 pci ca 4000 2 PCI BOX 0 connected to SB 9 PCI 9 pci ca 4000 3 PCI 0 pci cc 2000 1 PCI 1 pci cc...

Page 102: ...i d5 4000 2 PCI 5 pci d5 4000 3 PCI 6 pci d5 4000 4 PCI 7 pci d6 2000 1 PCI 8 pci d6 4000 2 PCI BOX 1 connected to SB a PCI 9 pci d6 4000 3 PCI 0 pci d8 2000 1 PCI 1 pci d8 4000 2 PCI 2 pci d8 4000 3 PCI 3 pci d9 2000 1 PCI 4 pci d9 4000 2 PCI 5 pci d9 4000 3 PCI 6 pci d9 4000 4 PCI 7 pci da 2000 1 PCI 8 pci da 4000 2 PCI BOX 0 connected to SB b PCI 9 pci da 4000 3 PCI 0 pci dc 2000 1 PCI 1 pci dc...

Page 103: ...i e5 4000 2 PCI 5 pci e5 4000 3 PCI 6 pci e5 4000 4 PCI 7 pci e6 2000 1 PCI 8 pci e6 4000 2 PCI BOX 1 connected to SB c PCI 9 pci e6 4000 3 PCI 0 pci e8 2000 1 PCI 1 pci e8 4000 2 PCI 2 pci e8 4000 3 PCI 3 pci e9 2000 1 PCI 4 pci e9 4000 2 PCI 5 pci e9 4000 3 PCI 6 pci e9 4000 4 PCI 7 pci ea 2000 1 PCI 8 pci ea 4000 2 PCI BOX 0 connected to SB d PCI 9 pci ea 4000 3 PCI 0 pci ec 2000 1 PCI 1 pci ec...

Page 104: ...i f5 4000 2 PCI 5 pci f5 4000 3 PCI 6 pci f5 4000 4 PCI 7 pci f6 2000 1 PCI 8 pci f6 4000 2 PCI BOX 1 connected to SB e PCI 9 pci f6 4000 3 PCI 0 pci f8 2000 1 PCI 1 pci f8 4000 2 PCI 2 pci f8 4000 3 PCI 3 pci f9 2000 1 PCI 4 pci f9 4000 2 PCI 5 pci f9 4000 3 PCI 6 pci f9 4000 4 PCI 7 pci fa 2000 1 PCI 8 pci fa 4000 2 PCI BOX 0 connected to SB f PCI 9 pci fa 4000 3 PCI 0 pci fc 2000 1 PCI 1 pci fc...

Page 105: ... 8d 2000 1 PCI 4 pci 8d 4000 2 PCI 5 pci 8d 4000 3 PCI 6 pci 8d 4000 4 PCI 7 pci 8e 2000 1 PCI 8 pci 8e 4000 2 PCI BOX 0 connected to SB 1 PCI 9 pci 8e 4000 3 PCI 0 pci 94 2000 1 PCI 1 pci 94 4000 2 PCI 2 pci 94 4000 3 PCI 3 pci 95 2000 1 PCI 4 pci 95 4000 2 PCI 5 pci 95 4000 3 PCI 6 pci 95 4000 4 PCI 7 pci 96 2000 1 PCI 8 pci 96 4000 2 PCI BOX 0 connected to SB 2 PCI 9 pci 96 4000 3 PCI 0 pci 9c ...

Page 106: ...i ad 4000 2 PCI 5 pci ad 4000 3 PCI 6 pci ad 4000 4 PCI 7 pci ae 2000 1 PCI 8 pci ae 4000 2 PCI BOX 0 connected to SB 5 PCI 9 pci ae 4000 3 PCI 0 pci b4 2000 1 PCI 1 pci b4 4000 2 PCI 2 pci b4 4000 3 PCI 3 pci b5 2000 1 PCI 4 pci b5 4000 2 PCI 5 pci b5 4000 3 PCI 6 pci b5 4000 4 PCI 7 pci b6 2000 1 PCI 8 pci b6 4000 2 PCI BOX 0 connected to SB 6 PCI 9 pci b6 4000 3 PCI 0 pci bc 2000 1 PCI 1 pci bc...

Page 107: ... c9 4000 2 PCI 5 pci c9 4000 3 PCI 6 pci c9 4000 4 PCI 7 pci ca 2000 1 PCI 8 pci ca 4000 2 PCI BOX 0 connected to SB 9 PCI 9 pci ca 4000 3 PCI 0 pci d0 2000 1 PCI 1 pci d0 4000 2 PCI 2 pci d0 4000 3 PCI 3 pci d1 2000 1 PCI 4 pci d1 4000 2 PCI 5 pci d1 4000 3 PCI BOX 0 connected to SB a PCI 6 pci d1 4000 4 PCI 7 pci d2 2000 1 PCI 8 pci d2 4000 2 PCI 9 pci d2 4000 3 PCI 0 pci d8 2000 1 PCI 1 pci d8 ...

Page 108: ...2000 1 PCI 4 pci f1 4000 2 PCI 5 pci f1 4000 3 PCI 6 pci f1 4000 4 PCI 7 pci f2 2000 1 PCI 8 pci f2 4000 2 PCI BOX 0 connected to SB e PCI 9 pci f2 4000 3 PCI 0 pci f8 2000 1 PCI 1 pci f8 4000 2 PCI 2 pci f8 4000 3 PCI 3 pci f9 2000 1 PCI 4 pci f9 4000 2 PCI 5 pci f9 4000 3 PCI 6 pci f9 4000 4 PCI 7 pci fa 2000 1 PCI 8 pci fa 4000 2 PCI BOX 0 connected to SB f PCI 9 pci fa 4000 3 SPARC Enterprise ...

Page 109: ...t Ex pci 1 700000 pci 0 pci 9 pci 0 pci 1 0 PCI 2 PCIE6 pci 1 700000 pci 0 pci 9 pci 0 pci 9 0 Basic PCI Slot PCI 3 pci 2 600000 0 PCI 3 PCIX1 pci 2 600000 pci 0 pci 1 pci 0 4 PCI 3 PCIX2 pci 2 600000 pci 0 pci 1 pci 0 1 4 PCI 3 PCIX5 pci 2 600000 pci 0 pci 8 pci 0 4 PCI 3 PCIX6 pci 2 600000 pci 0 pci 8 pci 0 1 4 PCI 3 PCIX3 PCI 3 IOBoat X pci 2 600000 pci 0 pci 9 pci 0 4 PCI 3 PCIX4 pci 2 600000 ...

Page 110: ...000 pci 0 pci 8 pci 0 1 4 PCI 2 PCIX3 pci 11 700000 pci 0 pci 9 pci 0 4 PCI 2 IOBoat X PCI 2 PCIX4 pci 11 700000 pci 0 pci 9 pci 0 1 4 PCI 2 PCIE1 pci 11 700000 pci 0 pci 1 pci 0 pci 0 0 PCI 2 PCIE2 pci 11 700000 pci 0 pci 1 pci 0 pci 1 0 PCI 2 PCIE3 pci 11 700000 pci 0 pci 1 pci 0 pci 9 0 PCI 2 PCIE4 pci 11 700000 pci 0 pci 9 pci 0 pci 0 0 PCI 2 PCIE5 pci 11 700000 pci 0 pci 9 pci 0 pci 1 0 PCI 2...

Page 111: ... 0 pci 0 0 PCI 1 PCIE2 pci 1 700000 pci 0 pci 1 pci 0 pci 1 0 PCI 1 PCIE3 pci 1 700000 pci 0 pci 1 pci 0 pci 9 0 PCI 1 PCIE4 pci 1 700000 pci 0 pci 9 pci 0 pci 0 0 PCI 1 PCIE5 pci 1 700000 pci 0 pci 9 pci 0 pci 1 0 PCI 1 IOBoat Ex PCI 1 PCIE6 pci 1 700000 pci 0 pci 9 pci 0 pci 9 0 Basic PCI Slot PCI 2 pci 2 600000 0 Basic PCI Slot PCI 3 pci 3 700000 0 PCI 3 PCIX1 pci 3 700000 pci 0 pci 1 pci 0 4 P...

Page 112: ...pci 7 700000 pci 0 pci 1 pci 0 pci 1 0 PCI 7 PCIE3 pci 7 700000 pci 0 pci 1 pci 0 pci 9 0 PCI 7 PCIE4 pci 7 700000 pci 0 pci 9 pci 0 pci 0 0 PCI 7 PCIE5 pci 7 700000 pci 0 pci 9 pci 0 pci 1 0 PCI 7 IOBoat Ex PCI 7 PCIE6 pci 7 700000 pci 0 pci 9 pci 0 pci 9 0 Basic PCI Slot PCI 0 pci 10 600000 0 Basic PCI Slot PCI 1 pci 11 700000 0 PCI 1 PCIX1 pci 11 700000 pci 0 pci 1 pci 0 4 PCI 1 PCIX2 pci 11 70...

Page 113: ...I 5 PCIX4 pci 15 700000 pci 0 pci 9 pci 0 1 4 PCI 5 PCIE1 pci 15 700000 pci 0 pci 1 pci 0 pci 0 0 PCI 5 PCIE2 pci 15 700000 pci 0 pci 1 pci 0 pci 1 0 PCI 5 PCIE3 pci 15 700000 pci 0 pci 1 pci 0 pci 9 0 PCI 5 PCIE4 pci 15 700000 pci 0 pci 9 pci 0 pci 0 0 PCI 5 PCIE5 pci 15 700000 pci 0 pci 9 pci 0 pci 1 0 PCI 5 IOBoat Ex PCI 5 PCIE6 pci 15 700000 pci 0 pci 9 pci 0 pci 9 0 Basic PCI Slot PCI 6 pci 1...

Page 114: ...QG1 SE0X7GQ1X and PRIMEPOWER250 450 secondary LAN port Gigabit Switches Product Name Connection JumboFrame Note FUJITSU SH4000 SH4322G SH4124T OK OK with SH4322G only CISCO Systems Catalyst3550 4000 6000 series OK OK with 6000 series only Extreme Networks Summit series OK OK with i series only 10 100Mbit Switches Product Name Connection Note FUJITSU SH1508 SH1508M SH1516 SH1816 SH1816TF SH1824 SH4...

Page 115: ...e Connection Available Function Name FUJITSU SH4322G OK LinkAggregation function 3Com Superstack 3 OK LinkAggregation function Hewlett Packard ProCurve 8000m OK Load Balancing function Extreme Networks Summit 1i 7i OK Load Sharing function CISCO Systems Catalyst3550 OK EtherChannel Function 108 ...

Reviews: