1.

 

Wiegand port 

The device is compatible with the Wiegand 26/34 output format. The contents 

of the protocol are as follows: 

1) 

Site Code

” 

is disabled 

 

The Card + Palm Vein mode (1: 1 verification)

 

  i. IC card: If the hexadecimal card number of an M1 S50 registration card is 

74C3CAFB, then: 

a)

 

When it is outputted in the Wiegand 26 output format, the last 3 bytes of 

the card number will be output, i.e., C3CAFB 

b)

 

When it is outputted in the Wiegand 34 output format, the last 4 bytes of 

the card number will be output, i.e., 74C3CAFB

 

            ii. For an ID card, the first 10 digits of the card number shown on the back of 
the card will be read. The Wiegand output format is the same as that of the IC card.

 

 

The Palm Vein mode (1: N Identification) 

In  this  mode,  the  door  access  control  number  is  the  output  number.  See 
step5 in "Operation instructions" for the door access control number setting 
rules. 

 

The Pin Code + Palm Vein mode (1: 1 Verification) 

The  output  method  of  this  mode  is  the  same  as  that  of  the  Palm  Vein 
mode. 

2) 

Site Code

” 

is enabled 

                       

If  the  hexadecimal  card  number  of  a  registration  card  is  74C3CAFB  and  the 

Site Code is set to be 200 (decimal), then: 

a)

 

If  the  output  format  is Wiegand  26,  the  last  two  bytes  of  the  output Site 
Code and card number is C8CAFB. 

b)

 

If  the  output  format  is Wiegand  34,  the  last  two  bytes  of  the  output Site 
Code and card number is 00C8CAFB. 

c)

 

If Corporate 1k is selected, the Site Code and card number will be output. 

d)

 

If  CSN  32  is  selected,  the  last  two  bytes  of  the  Site  Code  and  the  card 
number will be output without a parity bit: 00C8CAFB 

2. Electric lock and exit switch ports 

The device can be connected directly to the electric lock and exit switch. See 

Wiring Instructions for the connection method. 

3. Alarm / Doorbell ports 

The  device  can  be  connected  to  an  external  alarm  or  doorbell.  See  Wiring 

Instructions for the connection method. 

4. The Door Opening Test function 

If  the  device  is  connected  to  the  door  controller,  the  number  sent  for  the 

door-opening test is "1000000". A valid number "1000000" need to be registered on 
the  door  controller  before  the  door-opening  test  is  carried  out.  If  the  device  is 
connected to the electric lock, the door can be opened directly. 

Summary of Contents for PSN 900 Plus

Page 1: ...Identification Device PVID Operating Manual Version 1 0 0 Copyright belongs to Jiangsu Fujitsu Telecommunications Technology Co Ltd Copyright reserved can t change copy or print without permission offenders must be investigated ...

Page 2: ...1 C o n t e n t s Chapter1 Specifications 2 Chapter2 Structure Diagram 3 Chapter3 How to Put Hand 4 Chapter4 Operating Instructions 8 Chapter5 Output Protocol 33 Chapter6 Trobuleshooting 34 ...

Page 3: ...Humidity 0 50 relative humidity 30 80 No condensation Note The product is only suitable for indoor installation Lighting Environment Enrollment Authentication Natural light sunlight 2000Lux 3000Lux Fluorescent lamp light 2000Lux 3000Lux halogen light 500Lux 700Lux 13 Work Mode Palm Vein 1 N Note These three modes support separate card swiping PIN Code Palm Vein 1 1 Group Palm Vein 1 G Card Palm Ve...

Page 4: ...3 Chapter2 Structure Diagram PSN 900 Plus PVID structure diagram ...

Page 5: ...4 Chapter3 How to Put Hand Diagram of putting hand ...

Page 6: ...5 ...

Page 7: ...6 ...

Page 8: ...e except put hands accordance with the specification requirements strictly to keep the distance from the palm to the sensor should be 40 60mm if it prompts to adjust the palm location repeatedly this means that you did not mastered skills to put hands yet please replace the circle with a palm guide 4 In the following cases your enrolled palm vein templates may be incorrect authentication errors fa...

Page 9: ... boots up and the following screen appears After the boot up is completed the idle screen appears Step 2 Click the touch screen and then the Management button to enter the following screen If no system user is registered as an administrator it will prompt that an administrator should be registered duly Note A maximum of 10 administrators can be registered ...

Page 10: ...rd Palm Vein PIN Code Palm Vein or Group No Palm Vein mode Select the work mode to be used and then you can register an administrator or user 1 Palm Vein 2 Card Palm Vein recommended 3 PIN Code Palm Vein 4 Group No Palm Vein Step 4 After the work mode is selected click the Back button to enter the Main Menu screen Click User and Enroll in sequence to enter the following user ...

Page 11: ...ration depending on your need Click the Next button to enter the User ID Settings screen 1 Input ID settings by touching keys ID setting rules Up to 20 characters consisting of letters numbers or alphanumeric characters where letters are not case sensitive Note When assigning a user ID if there is the same number ID the user stored in the management system will cover that stored in the device 2 If...

Page 12: ... or User defined Door access control number setting rules Up to 10 characters all consisting of numbers which can be automatically the numeral part of a user ID or be customized as required but cannot begin with 0 Step 6 After the user ID is entered click the Next button to register a normal user administrator time zone user or temporary user by following screen prompts Step 7 Authentication After...

Page 13: ...12 2 When you are registered in the Card Palm Vein mode the idle screen is as follows 3 When you are registered in the PIN Code Palm Vein mode the idle screen is as follows ...

Page 14: ...ws Note During recognition in different modes there are acoustic prompts no matter whether the card swiping or recognition is successful or not Step 8 Management Click on the Management button in the idle screen After the administration is authenticated you can enter the Main Menu screen ...

Page 15: ...following settings screen You can set the network communication device number system time work mode system volume and LCD backlight respectively check system settings and select a identify mode 1 Network communication Click the Network button to enter the following screen ...

Page 16: ...Pass Network Management System and the device The device s default settings Network address IP Address 192 168 3 100 Subnet Mask 255 255 255 0 Gateway 192 168 3 1 Network Port 7777 Connection Password 123456 Monitoring server Turn on or off the function switch Enter the server address 2 Device Number Click the Device Number button to enter the device number setting screen The default device number...

Page 17: ...ⅰ Date Time Set the date and time of the device ⅱ Screensaver Time Set whether the system sleeps When the system sleeps the screen backlight is turned off The system can wake up when you click on the screen ⅲ NTP Server Turn on or off the function switch Enter the server address By default the time is synchronized with the server time every day iv Result Show Time Range 0 10s set according to need...

Page 18: ... Mode button to enter the following screen You can follow screen prompts to select the Palm Vein Card Palm Vein PIN Code Palm Vein or Group No Palm Vein mode depending on your need 5 System Volume Click the Volume button to enter the following screen You can follow screen prompts to choose to enable or disable the beep ...

Page 19: ...en Backlight Click the LCD Backlight button to enter the following screen You can follow screen prompts to click the or button or drag the slider to increase or decrease the screen brightness which is recommended to be 03 or less The default brightness of the screen backlight is 03 7 System Information You can click the System Info button to check system settings 8 Identify Mode Click the Identify...

Page 20: ... recognized 2 User Management Click the User Management button to enter the following screen You can follow screen prompts to enroll query edit and delete users 1 User Enrollment Click Enroll Repeat Step 4 5 and 6 to register users with different permissions 2 Query Users You can click Query to browse registered users through Precise Search or Listing ...

Page 21: ...h to enter the following screen Enter a user ID for precise search ⅱ Click List Mode to enter the following screen Click the Edit button in the User Operation screen and then you can enter the user information editing screen ...

Page 22: ... assign a card to the user by card swiping 3 Edit a user Click on Edit to enter the following interface Follow screen prompts to input a user ID and click the Next button to enter the user information editing screen You can edit the user s information with the above steps 4 Delete Users Click the Delete Users button to enter the following screen ...

Page 23: ...an be deleted 3 Security Management Click the Security button to enter the following screen and then you can set access control options power supply restore factory settings and upgrade software respectively 1 Set Access Control Click the Access Control button to enter the following screen ...

Page 24: ...e Zone Management Click on Time Zone to enter the following interface and then you can carry out the oppeartions of Time Zone Information Management and Ttime Zone Group Management Notes a To register a time zone user you must first set a time zone and a time zone group A time zone user has permissions only within the valid time zone b A maximum of 20 time zone and 20 time zone groups can be set ...

Page 25: ...ntrol Signal Settings Click the Door Control Signal button to enter the following screen Follow screen prompts to select an appropriate item To be connected to the door controller select Wiegand 26 Wiegand 34 CORP 1K Corporate 1000 or CSN32 If an electric lock is connected select Electric Lock Output To be used for work check in without output select No output ⅲ Door Open Time ...

Page 26: ...limited to the case of connecting to the electric lock directly ⅳ Alarm Settings Click the Alarm button to enter the following screen You can follow screen prompts to carry out settings of the Door Sensor Alarm Tamper Alarm Alarm Signal Output Alarm Time and Anti Tali Alarm ⅰ Door Sensor Alarm Click the Door Sensor Alarm button to enter the following screen ...

Page 27: ...r having been connected ⅱ Tamper Alarm Click the Tamper button to enter the following screen You can choose to enable or disable the Tamper alarm function If the tamper alarm is enabled when the device is dismantled the device itself or the external alarm will issue an alarm ⅲ Alarm Signal Output Click the Signal Transfer Output button to enter the following screen and then you can select Local Al...

Page 28: ...larm Time button to enter the following screen and then you can choose the alarm duration Note This function is valid only when the alarm is enabled ⅴ Anti Tail Alarm Click the Anti Tail Alarm button to enter the following screen ...

Page 29: ... issue an alarm Notes a In order to ensure the safety of the dogged or menaced person when this function is enabled an external alarm must be selected and connected properly b Even if the device is in the sleep state black screen or idle state when you click the area shown in the figure an alarm will be issued c The square shown in the figure is used for marking the specified area and is not visib...

Page 30: ...ct swiping mode can also be supported in the palm vein mode group No mode or PIN code palm vein mode ⅷ Site Code Click the Site Code button to enter the following Site Code setting interface Follow the prompts to carry out Site Code settings See Chapter5 Output Protocol for details 2 Power Supply Management Click the Power Supply button to enter the following screen ...

Page 31: ...ease do it cautiously 4 Upgrade Firmware Insert the U disk stored with the upgrade package into the device and click Upgrade Firmware and then the software can be upgraded Upgrade package file format up010000 tar gz where 010000 represents the version number 01 00 00 Note You can upgrade Firmware either with the U disk or remotely through the PalmPass Network Management System 4 Data Management Cl...

Page 32: ...ton to enter the following screen and then you can browse and clear access records as well as the device s records ⅰ Browse access records and the device s records Click Access Log Query and Device Log Query respectively to enter the following screen and then you can browse access records and the device s records respectively or export access records and the device s records respectively to a U di...

Page 33: ... the device s records Click Access Log Clear and Device Log Clear respectively to enter the following screen and then you can clear all of the access records and the device s records respectively Please do this operation cautiously ...

Page 34: ...e Palm Vein mode 2 Site Code is enabled If the hexadecimal card number of a registration card is 74C3CAFB and the Site Code is set to be 200 decimal then a If the output format is Wiegand 26 the last two bytes of the output Site Code and card number is C8CAFB b If the output format is Wiegand 34 the last two bytes of the output Site Code and card number is 00C8CAFB c If Corporate 1k is selected th...

Page 35: ...alm guide support instead 4 Registration failure Please check whether the ambient lighting meets the requirements the sensor surface is dirty the palm is clean and the palm is placed correctly 5 The device is connected to the door controller where the recognition is successful but the door cannot be opened Please check whether you have been registered as a valid user for the door controller and ha...