Replacement routines
Replacing the IDTEMP combo
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.8
Replacing the IDTEMP combo
This board includes two important system components:
–
EEPROM for the chassis ID and ident number of the server
–
temperature sensor for monitoring the environment temperature
The current temperature values and EEPROM data are transmitted to the
system board via the connected I
2
C bus.
The IDTEMP combo must be correctly installed in order:
–
to monitor the temperature correctly,
–
to enable the server management to display the correct system picture,
–
to install the server using ServerStart.
The IDTEMP combo is situated on a separate holder under the hard disk cage.
Ê
Open the server as described in the
section “Preparation” on page 17
Figure 11: Removing the holder
Ê
Push the holder in direction of the arrow.