18
Operating Manual
TX1330 M2
Functional overview
Cool-safe
®
Advanced Thermal Design
The Cool-safe
®
Advanced Thermal Design option allows you to operate the
system within a wider temperature range of 5 °C to 40 °C.
V
CAUTION
In a system that has the Cool-safe® Advanced Thermal Design Option,
only components that support the higher operating range may be
installed. Further information on this is available in the configurator.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory
and automatically corrected with the error correcting code (ECC) method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in
the event of an error and automatically "hides" the defective system
components.
The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes
and monitors all components that are critical for system reliability.
A RAID controller supports different RAID levels and increase the availability
and data security of the system.
The hot-plug HDD modules provide additional availability.
This option can only be ordered from the manufacturer and is
indicated by the logo on the identification rating plate.