U41100-J-Z156-1-74
15
PRIMERGY S40-DF capacity extension Converting the PRIMERGY S40-DF
Figure 11: 1-Setting up the channel configuration
Ê
Connect the supplied OLR/STM-LVD flat ribbon cable as follows:
–
Connect the common end (4) of the two cable strands with the
connector X5 on the STM-LVD module on the backplane of cage 1 (see
also figure 12 on page 16).
–
Connect the shorter strand (5) with the connector X4 on the backplane
of cage 2 (see also figure 12 on page 16).
–
Connect the longer strand (6) with the connector X4 on the backplane of
cage 3 (see also figure 12 on page 16).
This cable determines the SCSI addresses of the drives located in the SCSI
cages 2 and 3 in the 1-channel configuration.
c a g e 3
3 . 1
c a g e 1
c a g e 2
3 . 2
3 . 3
5
6
4