14
U41100-J-Z156-1-74
Converting the PRIMERGY S40-DF PRIMERGY S40-DF capacity extension
Figure 10: Controller backplane: SCSI ports - initial state
Ê
Pull out the SCSI connection cable for cage 1 (3.1) from the controller
backplane (see also figure 8 on page 12) and connect it to the freed SCSI
connector X1 (see figure 12 on page 16) on the backplane of cage 2 (see
figure 11 on page 15).
Ê
Pull out the SCSI connection cable for cage 2 (3.2) from the controller
backplane (see also figure 8 on page 12) and connect it to the freed SCSI
connector X1 (see figure 12 on page 16) on the backplane of cage 3 (see
figure 11 on page 15).
Ê
Pull out the SCSI connection cable for cage 3 (3.3) from the controller
backplane (see also figure 8 on page 12) and connect it to the first SCSI port
on the backplane of the controller (see figure 11 on page 15 and
figure 12 on page 16).
3 . 1
3 . 3
3 . 2