M2
Hardware installation
5.5
Connecting the server to the mains
In its basic configuration level the server has a hot-plug power supply unit.
A second hot-plug power supply unit can be added to ensure a redundant power
supply. If one power supply unit is defective, the other then guarantees
unimpaired operation. Each hot-plug power supply unit can be replaced during
operation (see the "FUJITSU Server PRIMERGY TX2560 M2 / RX2560 M2
Server Upgrade and Maintenance Manual").
V
CAUTION!
The power supply unit automatically sets itself to a mains voltage range
from 100 V to 240 V (Platinum) or 200 V to 240 V (Titanium). You may
only operate the server if its rated voltage range corresponds to the local
mains voltage.
Ê
Connect the power cord to the server power supply unit.
Ê
Connect the power cord to a grounded mains outlet in the in-house power
supply network or a power outlet of the socket strip in the rack (see Technical
Manual for rack).
I
A phase redundancy in the power supply of the server can be set up if
two hot-plug power supply units are installed.
In this case, each of the power supply units is either connected to two
different phases or to two separate circuits of the internal power supply
network.
Summary of Contents for PRIMERGY RX2560 M2
Page 8: ...Operating Manual TX2560 M2 RX2560 M2 Contents ...
Page 12: ...12 Operating Manual TX2560 M2 RX2560 M2 Introduction ...
Page 32: ...32 Operating Manual TX2560 M2 RX2560 M2 Functional overview ...
Page 48: ...48 Operating Manual TX2560 M2 RX2560 M2 Important information ...
Page 80: ...80 Operating Manual TX2560 M2 RX2560 M2 Starting up and operation ...
Page 82: ...82 Operating Manual TX2560 M2 RX2560 M2 Property and data protection ...
Page 90: ...90 Operating Manual TX2560 M2 RX2560 M2 Troubleshooting and tips ...