To eject the iRMC microSD card, gently push it in and then let go (1).
▶
Pull the iRMC microSD card straight out of its slot (2).
CAUTION
(not valid for Europe, Middle East, India and Africa)
The iRMC microSD card contains customer information.
▶
After removing the iRMC microSD card, hand the card over to
the customer.
▶
If the customer requests disposal of the defective microSD card,
proceed as follows: Using a pair of side-cutting pliers, cut the
microSD card in half.
Concluding steps
▶
If applicable, install the expansion card in slot 5 and 6, see
▶
.
▶
"Connecting the power cord" on page 65
.
▶
"Switching on the server" on page 69
.
▶
If applicable,
"Installing the front cover with lock" on page 69
.
16.5.4 Replacing the iRMC microSD card
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 20 minutes
(Firmware restore:
depending on configuration)
Tools:
Phillips PH2 / (+) No. 2 screw driver (for cover 2)
Preliminary steps
▶
"Locating the defective server" on page 49
.
▶
If applicable,
"Removing the front cover with lock" on page 52
System board and components
494
Upgrade and Maintenance Manual
RX2540 M6
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...