Press the two green buttons inward to release the locking mechanism (1).
▶
Fold the cover 1 up (2).
▶
Remove the cover 1 upward (3).
Removing the cover 2
Figure 10: Removing the cover 2
▶
Loosen the screw (1).
▶
Push the cover 2 to the rear side using the green touch points (2).
▶
Remove the cover 2 upward (3).
4.6
Reassembling
4.6.1
Safety notes
CAUTION
▶
Before attaching the covers, make sure no unnecessary parts or
tools are left inside the server.
▶
The top cover must be replaced as soon as possible for purposes
of cooling, to comply with EMC regulations (regulations regarding
electromagnetic compatibility) and to prevent fires.
▶