8.6
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the
Main
menu, using
System Date
and
System Time
respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY RX2540 M1 Upgrade and Maintenance
Manual") or contact our customer service team.
8.7
System will not boot
The system will not boot after installing a new hard disk drive.
SAS configuration incorrect
Ê
Check the settings for the hard disk drives (
SAS Device Configuration
) and the
additional settings in the SAS configuration menu.
8.8
Hard disk drive error messages at system
boot
Various hard disk drive error messages may occur when the system is
rebooted. These error messages are caused by modifications in the selected
RAID configuration.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller
configuration program.
Summary of Contents for PRIMERGY RX2540 M1
Page 6: ...Operating Manual RX2540 M1 ...
Page 10: ...Operating Manual RX2540 M1 Contents ...
Page 14: ...14 Operating Manual RX2540 M1 Introduction ...
Page 62: ...62 Operating Manual RX2540 M1 Hardware installation ...
Page 82: ...82 Operating Manual RX2540 M1 Starting up and operation ...
Page 84: ...84 Operating Manual RX2540 M1 Property and data protection ...
Page 92: ...92 Operating Manual RX2540 M1 Troubleshooting and tips ...