Product description
Advanced Thermal Design (ATD)
The ATD option allows you to operate the system with a wider temperature
range either of 5 °C to 40 °C or 5 °C to 45 °C, depending on your system and
configuration.
V
CAUTION
In a system that is configured with ATD, only certain components which
support the respectively increased higher operating temperature range
may be installed and used. For applicable restrictions, see the official
configurator tool.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory
and automatically corrected with the Error Correcting Code (ECC) method.
Automatic Server Reconfiguration and Restart (ASR&R) restarts the system in
the event of an error and automatically "hides" the defective system
components.
The Prefailure Detection and Analysis (PDA) technology from Fujitsu analyzes
and monitors all components that are critical for system reliability.
A RAID controller supports different RAID levels and increase the availability
and data security of the system.
The HDD/SSD modules provide additional availability.
iRMC S5 with integrated management LAN connector
The iRMC S5 (
i
ntegrated
R
emote
M
anagement
C
ontroller) is a Baseboard
Management Controller (BMC) with integrated management LAN connector
and expanded functionality that was previously only available with additional
plug-in cards. In this way, the iRMC S5 enables complete control of PRIMERGY
servers, regardless of system status, and thus particularly the control of
PRIMERGY servers that are in the "out-of-band" system status.
This option can only be ordered from the
manufacturer and is indicated by the respective
logo on the identification rating plate.
Summary of Contents for PRIMERGY RX2520 M5
Page 8: ...Operating Manual RX2520 M5 Contents ...
Page 10: ...10 Operating Manual RX2520 M5 Introduction ...
Page 14: ...14 Operating Manual RX2520 M5 Before you start ...
Page 38: ...38 Operating Manual RX2520 M5 Product description ...
Page 70: ...70 Operating Manual RX2520 M5 Starting up ...
Page 88: ...88 Operating Manual RX2520 M5 Troubleshooting and tips ...
Page 98: ...98 Operating Manual RX2520 M5 Warranty and service ...