RX2520 M4
Operating Manual
71
Starting up and operation
I
Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
I
For further details on detected errors, refer to the System Event Log
(SEL) or use the ServerView Operations Manager or iRMC S5 web
interface.
Pos. Indicator
Status
Description
1
ID
indicator,
see also
"iRMC-
related
status
signals" on
page 67
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
interface or the ID button on the front panel for
easy identification.
blue
flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
Global
Error
indicator,
see also
"iRMC-
related
status
signals" on
page 67
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified range
– Defective sensor
– CPU error
– Error detected by server management
software
CSS
indicator
off
No critical event detected (CSS component).
orange
on
Prefailure event detected (CSS component).
orange
flashing
CSS component failure detected.
Summary of Contents for PRIMERGY RX2520 M4
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY RX2520 M4 Operating manual October 2017 ...
Page 8: ...Operating Manual RX2520 M4 Contents ...
Page 12: ...12 Operating Manual RX2520 M4 Introduction ...
Page 32: ...32 Operating Manual RX2520 M4 Functional overview ...
Page 48: ...48 Operating Manual RX2520 M4 Important information ...
Page 86: ...86 Operating Manual RX2520 M4 Property and data protection ...