84
Operating Manual
RX200 S7
Troubleshooting and tips
8.6
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the Main menu, using System Date and System Time respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual) or contact
our customer service team.
8.7
System will not boot
The system will not boot after installing a new hard disk drive.
SAS configuration incorrect
Ê
Check the settings for the hard disk drives (SAS Device Configuration) and
the additional settings in the SAS configuration menu.
8.8
Drives reported as “dead” when starting
system
This error message can occur when the onboard SAS controller has RAID
functionality or the server is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
Summary of Contents for PRIMERGY RX200 S7
Page 1: ...Operating Manual English PRIMERGY RX200 S7 Server Operating Manual Edition April 2012 ...
Page 6: ...Operating Manual RX200 S7 ...
Page 10: ...Operating Manual RX200 S7 Contents ...
Page 32: ...32 Operating Manual RX200 S7 Functional overview ...
Page 78: ...78 Operating Manual RX200 S7 Starting up and operation ...
Page 80: ...80 Operating Manual RX200 S7 Property and data protection ...