Hardware Installation
Connecting the Server to the Mains
4.4
Connecting the Server to the Mains
In its basic configuration level the server has a hot-pluggable power supply unit.
A second hot pluggable power supply unit can be added to achieve a redundant
power supply. If a defect occurs in one power supply unit, the other power supply
unit ensures continued operation of the server.
V
CAUTION!
The installed power supply units automatically set themselves to a
voltage in the range of 100 V - 240 V. Make sure that your local mains
voltage is within this range.
Figure 10: Connecting the Server to the Mains
Ê
Connect the power cable with the insulated connector to the power supply
unit of the server (1), and plug the power plug into a grounded outlet on the
mains socket strip (2) on the rack (see Technical Manual of the rack).
I
If the server has two hot pluggable power supply units, the server can be
connected to the mains with phase redundancy.
In this case, the two power supply units are connected to two different
phases.