382
Upgrade and Maintenance Manual
RX100
S7
System board and components
7. Install all expansion cards see section
"Expansion cards and riser
modules" on page 199
.
I
Make sure that you reinstall each card in the slots it was located
before the replacement.
8.
"Closing the server" on page 66
9.
"Installing the server in the rack" on page 68
10.Connect all external cables.
11.
"Updating the system board BIOS and iRMC" on page 81
12.If applicable, activate TPM functionality in the system BIOS under
Security
>
TPM (Security Chip) Setting
>
Security Chip
. For more
information, refer to the "D3034 BIOS Setup Utility for PRIMERGY
RX100 S7 Reference Manual".
13.
"Verifying system information backup / restore" on page 83
14.If customer BIOS settings are not restored automatically, please change
the settings manually (using the information collected during "preliminary
steps"). If you couldn't determine the BIOS version, ask the customer to
reconfigure all BIOS settings and password.
V
CAUTION!
The system event log entry
Chassis IDPROM: Restore
successful
(see section
"Verifying system information
backup / restore" on page 83
) is not valid if you updated the
system board BIOS from version 1.15.0 or below to version 1.18.0
or above.
15.
"Verifying the system time settings" on page 91
16.
"Looking up changed MAC / WWN addresses" on page 96
17.
"Updating the NIC configuration file in a Linux environment" on page 93
18.
"Enabling SVOM boot watchdog functionality" on page 89
19.
"Switching on the server" on page 72
20.
"Enabling BitLocker functionality" on page 94
Summary of Contents for PRIMERGY RX100 S7
Page 6: ...Upgrade and Maintenance Manual RX100 S7 ...
Page 8: ...Upgrade and Maintenance Manual RX100 S7 Version history ...
Page 28: ...Upgrade and Maintenance Manual RX100 S7 Contents ...
Page 54: ...54 Upgrade and Maintenance Manual RX100 S7 Important information ...
Page 74: ...74 Upgrade and Maintenance Manual RX100 S7 Basic hardware procedures ...
Page 142: ...142 Upgrade and Maintenance Manual RX100 S7 Power supply ...
Page 172: ...172 Upgrade and Maintenance Manual RX100 S7 Hard disk drives solid state drives ...
Page 268: ...268 Upgrade and Maintenance Manual RX100 S7 Expansion cards and backup units ...
Page 278: ...278 Upgrade and Maintenance Manual RX100 S7 Main memory ...
Page 296: ...296 Upgrade and Maintenance Manual RX100 S7 Processor ...
Page 310: ...310 Upgrade and Maintenance Manual RX100 S7 Optical disk drive ...
Page 316: ...316 Upgrade and Maintenance Manual RX100 S7 Front panel ...
Page 346: ...346 Upgrade and Maintenance Manual RX100 S7 Management and diagnostics modules ...
Page 384: ...384 Upgrade and Maintenance Manual RX100 S7 System board and components ...
Page 464: ...464 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 349 SKD red PSU ...
Page 465: ...RX100 S7 Upgrade and Maintenance Manual 465 Appendix Figure 350 SKD std PSU ...
Page 466: ...466 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 351 Std PSU 3 5 inch SATA ODD ...
Page 467: ...RX100 S7 Upgrade and Maintenance Manual 467 Appendix Figure 352 Red PSU 3 5 inch SATA ODD ...
Page 468: ...468 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 353 Std PSU 2 5 inch SATA ODD ...
Page 469: ...RX100 S7 Upgrade and Maintenance Manual 469 Appendix Figure 354 Red PSU 2 5 inch SATA ODD ...
Page 470: ...470 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 355 Std PSU 3 5 inch SAS ...
Page 471: ...RX100 S7 Upgrade and Maintenance Manual 471 Appendix Figure 356 Red PSU 3 5 inch SAS ...
Page 472: ...472 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 357 Std PSU 2 5 inch SAS ...
Page 473: ...RX100 S7 Upgrade and Maintenance Manual 473 Appendix Figure 358 Red PSU 2 5 inch SAS ...
Page 478: ...478 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 363 Std PSU 3 5 inch SAS iBBU ...
Page 479: ...RX100 S7 Upgrade and Maintenance Manual 479 Appendix Figure 364 Std PSU 3 5 inch SAS FBU ...
Page 480: ...480 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 365 Std PSU 2 5 inch SAS iBBU ...
Page 481: ...RX100 S7 Upgrade and Maintenance Manual 481 Appendix Figure 366 Std PSU 2 5 inch SAS FBU ...
Page 482: ...482 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 367 Red PSU 3 5 inch SAS iBBU ...
Page 483: ...RX100 S7 Upgrade and Maintenance Manual 483 Appendix Figure 368 Red PSU 3 5 inch SAS FBU ...
Page 484: ...484 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 369 Red PSU 2 5 inch SAS iBBU ...
Page 485: ...RX100 S7 Upgrade and Maintenance Manual 485 Appendix Figure 370 Red PSU 2 5 inch SAS FBU ...
Page 486: ...486 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 371 Std PSU 3 5 inch SATA ODD LSP ...
Page 487: ...RX100 S7 Upgrade and Maintenance Manual 487 Appendix Figure 372 Std PSU 2 5 inch SATA ODD LSP ...
Page 488: ...488 Upgrade and Maintenance Manual RX100 S7 Appendix Figure 373 Red PSU 3 5 inch SATA ODD LSP ...
Page 489: ...RX100 S7 Upgrade and Maintenance Manual 489 Appendix Figure 374 Red PSU 2 5 inch SATA ODD LSP ...
Page 490: ...490 Upgrade and Maintenance Manual RX100 S7 Appendix ...