Checking the Included Items Supplied

Check that the following items are supplied before using this product.
If any parts are missing, please contact an office listed in "Appendix A Contact Information" 
(

J

pg.21).

Microsoft, Windows, Windows Server are trademarks or registered trademarks of the Microsoft
Corporation in the USA and other countries.
Other product names used are trademarks or registered trademarks of their respective manufacturers.

All Rights Reserved, Copyright© FUJITSU LIMITED 2005

• Remote Service Board (this product)

• User's Guide (this document) 

• external power supply

(adapter unit + power cable)

*: For use in Japan only.

• IO cable

• Server control cable

4-pin

3-pin

Summary of Contents for PRIMERGY PG-RSB104

Page 1: ...J E B7FY 1561 02 リモートサービスボード取扱説明書 Remote Service Board User s Guide PG RSB104 ...

Page 2: ...注意 をよくお読みにな り 理解されたうえで本製品をお使いください また本書は 本製品の使用中にいつでもご覧になれるよう大切に保管してください 本製品のハイセイフティ用途での使用について 本製品は 一般事務用 パーソナル用 家庭用 通常の産業用等の一般的用途を想定して設計 製造されて いるものであり 原子力施設における核反応制御 航空機自動飛行制御 航空交通管制 大量輸送システム における運行制御 生命維持のための医療器具 兵器システムにおけるミサイル発射制御など 極めて高度 な安全性が要求され 仮に当該安全性が確保されない場合 直接生命 身体に対する重大な危険性を伴う用 途 以下 ハイセイフティ用途 という に使用されるよう設計 製造されたものではございません お客 様は 当該ハイセイフティ用途に要する安全性を確保する措置を施すことなく 本製品を使用しないでくだ さい ハイセイフティ用途...

Page 3: ...の表示を無視して 誤った取り扱いをすると 人が死亡する可能性 または重傷を負う可能性があることを示しています 注意 この表示を無視して 誤った取り扱いをすると 人が損害を負う可能 性があること および物的損害のみが発生する可能性があることを示 しています で示した記号は 警告 注意を促す内容であることを告げるもので す 記号の中やその脇には 具体的な警告内容が示されています で示した記号は してはいけない行為 禁止行為 であることを告 げるものです 記号の中やその脇には 具体的な禁止内容が示されて います で示した記号は 必ず従っていただく内容であることを告げるもの です 記号の中やその脇には 具体的な指示内容が示されています 記号 意味 お使いになる際の注意点や してはいけないことを記述しています 必ずお読みください ハードウェアやソフトウェアを正しく動作させるために必要なことが 書いて...

Page 4: ...に修理をご依頼くださ い お客様自身による修理は危険ですから絶対におやめください 異常状態の まま使用すると 火災 感電の原因となります リモートサービスボードに添付の AC アダプタは サーバ本体の動作状態 動 作時 休止時 にかかわらず 周囲温度が 0 35 の環境を守ってご使用くだ さい 特に夏場は 必要に応じて夜間 休日にも冷房を入れて 周囲温度が 35 を超えないようにしてください 温度条件が守られないと 火災 故障の原 因となります 本製品をサーバ本体に取り付けたり取り外したりする際には 安全のためサー バ本体および接続されている装置の電源スイッチを切り 電源プラグをコンセ ントから抜いたあとに行ってください AC アダプタの電源プラグもコンセント から抜いてください 電源を入れたまま本製品を取り付けたり取り外したりす ると 装置の故障 発煙などが起こる可能性があり また感電の...

Page 5: ... 感電の原因 となります 表示された電源電圧以外の電圧で使用しないでください また タコ足配線を しないでください 火災 感電の原因となります 近くで雷が発生したときは 電源ケーブルやモジュラケーブルをコンセントか ら抜いてください そのまま使用すると 雷によっては装置を破壊し 火災の 原因となります 取り外したカバー キャップ ネジ 電池などは 小さなお子様が誤って飲む ことがないように 小さなお子様の手の届かないところに置いてください 万 一 飲み込んだ場合は ただちに医師と相談してください 本製品を勝手に改造しないでください 火災 感電の原因になります 取扱説明書に記載されていない AC アダプタは使用しないでください また AC アダプタの改造 分解はしないでください 火災 けがの原因となります 使用中の AC アダプタは 布でおおったり 包んだりしないでください 熱が こもり 火...

Page 6: ...たは担当保守員までご連絡ください Microsoft Windows Windows Server は 米国 Microsoft Corporation の米国およびその他の国におけ る登録商標または商標です 本取扱説明書に記載されている会社名 製品名は 各社の登録商標または商標です All Rights Reserved Copyright FUJITSU LIMITED 2005 保証書 リモートサービスボード 本製品 取扱説明書 本書 IO ケーブル AC アダプタ 本体 電源ケーブル サーバ制御ケーブル 4ピン 3ピン ...

Page 7: ...は含まれません 本製品の詳細は サーバ本体に添付の ドキュメント ツール CD 内の ServerView ユーザーズガイド を参照してください また 本製品のサーバ本体への取り付け 取り外し方法は サーバ本体に添付の ドキュ メント ツール CD 内の ユーザーズガイド を参照してください 1 2 仕様 本製品の仕様を次に示します 本製品を使用するには ServerView が必要です 必ずインストールしてください ServerView の機能については ServerView ユーザーズガイド を参照してくださ い 品名 リモートサービスボード 型名 PG RSB104 対応スロット PCI スロット 信号は使用せず 外部インタフェース LAN 10BASE T 100BASE TX コネクタ IO コネクタ VGA USB AC アダプタ LAN コネクタ AC アダプタ 出力電圧 D...

Page 8: ...IO ケーブルの接続方法 IO ケーブルの接続方法について説明します 1 IO ケーブルの IO コネクタを 本製品側の IO コネクタ に接続します 2 IOケーブルのUSBコネクタを サーバ本体側のUSBコネクタに接続します 3 IO ケーブルの VGA コネクタを VGA コネクタに接続します 4 IO ケーブルの AC アダプタコネクタを AC アダプタのプラグに接続します 5 IO ケーブルのディスプレイコネクタを VGA ケーブルに接続します サーバ制御ケーブル IOケーブル へ LANケーブル へ コンセント IOコネクタ 本製品側に接続 VGAコネクタ VGAコネクタに接続 USBコネクタ サーバ本体側に接続 ACアダプタコネクタ ACアダプタに接続 ディスプレイコネクタ VGAケーブルに接続 ...

Page 9: ...ください 感電の原因となります AC アダプタが傷んだとき コンセントの差し込み口がゆるいときは使用しない でください そのまま使用すると 火災 感電の原因となります AC アダプタの電極 およびコンセントの差し込み口にほこりが付着している場 合は 乾いた布でよく拭いてください そのまま使用すると 火災 感電の原因 となります 表示された電源電圧以外の電圧で使用しないでください また タコ足配線を しないでください 火災 感電の原因となります 取扱説明書に記載されていない AC アダプタは使用しないでください また AC アダプタの改造 分解はしないでください 火災 けがの原因となります 使用中の AC アダプタは 布でおおったり 包んだりしないでください 熱が こもり 火災の原因となります 電源プラグを抜くときはケーブルを引っ張らず 必ずプラグを持って抜いてく ださい ケーブルを引っ張る...

Page 10: ...OST でキーボードのエラーが表示さ れるかどうかを確認してください 本製品の Web インターフェース の Manage タブから Power Server OFF を実行し た場合 次のような動作となります 対象のサーバ上で ServerView Agent が動作している場合 ServerView Agent により OS のシャットダウンが実行されます 対象のサーバ上で ServerView Agent が動作していない場合 シャットダウンは実行されず Power OFF が実行されます 次の 2 つは 本製品ではサポートしません SystemEventLog のクリア Manage タブをクリックし System Event Log の Clear ボタンを押下してもシ ステムイベントログはクリアされません Error clearing System Event Log または ...

Page 11: ...iew から該当のログを確認してください 本製品のログから障害内容を判定 する場合は 次を参照してください DIMM の HotSpare 状態でシングルビットエラーが発生した場合 RSB のログには unrecognized event が記録されていますが これは ServerView の Memory redundancy lost に対応するものです Memory redundancy lost に対応する unrecognized event の前には 必ず DIMM の disabled および 別 DIMM の spare device used removed イベントが記録されます これらの先行するログから DIMM の 冗長性が失われたかどうかを判断できます ...

Page 12: ...12 ...

Page 13: ... and manufactured as contemplated or general use including without limitation general office use personal use household use and ordinary industrial use but are not designed developed and manufactured as contemplated for use accompanying fatal risks or dangers that unless extremely high safety is secured could lead directly to death personal injury severe physical damage or other loss hereinafter H...

Page 14: ...ections These sections explain information needed to operate the hardware and software properly Make sure to read these sections This mark indicates reference pages or manuals In the event of heat smoke a strange smell or noise being emitted from the device immediately turn off the power and unplug from the power source Check that the smoke has gone and contact an office listed in the Contact Info...

Page 15: ...can cause an electric shock or fire Use a dry cloth to remove all dust from plug pins of the AC adapter and power outlet If you continue using them without removing dust it can cause an electric shock or fire Do not use a voltage other than that displayed Also do not use a double adapter Doing so may cause an electric shock or fire If electrical storms are occurring nearby unplug the power cable a...

Page 16: ...ows Server are trademarks or registered trademarks of the Microsoft Corporation in the USA and other countries Other product names used are trademarks or registered trademarks of their respective manufacturers All Rights Reserved Copyright FUJITSU LIMITED 2005 Remote Service Board this product User s Guide this document external power supply adapter unit power cable For use in Japan only IO cable ...

Page 17: ... product For details about this product refer to ServerView User s Guide in Document Tool CD provided with the server For details about installing removing this product to from the server refer to User s Guide in Document Tool CD provided with the server 1 2 Specifications The following shows the specifications of this product To use this product ServerView is required Be sure to install it For de...

Page 18: ... IO cable to the IO connector 1 of this product 2 Connect the USB connector of the IO cable to the USB connector of the server 3 Connect the VGA connector of the IO cable to the VGA connector 4 Connect the AC adapter connector of the IO cable to the plug of the AC adapter 5 Connect the Display connector of the IO cable to the VGA cable Display Remote Service Board 2 LAN connector 1 IO connector 1 ...

Page 19: ...ay is 70Hz In case of poor resolution of the dis play set the screen refresh rate to 70Hz When this product is installed an error in the keyboard connected to the server may not be detected by POST If the keyboard does not work well restart the server after disconnecting the USB cable that connects this product and the server and then check if the keyboard error is dis played by POST Power On Self...

Page 20: ...stem Event Log using tools IPMVIEW exe provided with this server Also FAN errors will not be notified by e mail or traps SEL messages When referring to the PRIMERGY RX600 S2 SEL from the Web Interface of this product a log will displays an unrecognized event When this message appears check the relevant log from ServerView When judging whether a failure has occurred using a log of this product the ...

Page 21: ...nd East Hong Kong Indonesia PT Fujitsu Systems Indonesia Offices Headquarters Tel 62 21 570 9330 Hunting Fax 62 21 573 5150 Address Wisma Kyoei Prince 10th Floor Jl Jend Sudirman Kav 3 4 Jakarta Indonesia 10220 Korea Fujitsu Korea Ltd Tel 82 2 3787 6000 Fax 82 2 3787 6066 Address Susong Tower Building 83 1 Susong Dong Jongno Gu Seoul Republic of Korea 110 140 Malaysia Fujitsu Malaysia Sdn Bhd Tel ...

Page 22: ...500 Fax 66 2 500 1555 Address 12th Floor Olympia Thai Tower 444 Rachadapisek Road Samsennok Huaykwang Bangkok Thailand 10310 Vietnam Fujitsu Vietnam Limited Tel 84 4 831 3895 Fax 84 4 831 3898 Address Unit 802 8th floor Fortuna Tower Hanoi 6B Lang ha Street Ba dinh District Hanoi Socialist Republic of Vietnam United States Fujitsu Computer Systems Corporation Tel 1 800 831 3183 Fax 1 408 496 0575 ...

Page 23: ...s or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu Any manual which has missing pages or which is incorrectly collated will be replaced PRIMERGY リモートサービスボード PG RSB104 取扱説明書 Remote Service Board PG RSB104 User s Guide B7FY 1561 02 00 発 行 日 発行責任 2005 年 10 月 富士通株式会社 Issued on Iss...

Page 24: ...このマニュ アルはリサイ クルに配慮し て製本されています 不要になった際は 回収 リサイ クルに出し て く だ さい ...

Reviews: