BX400 S1
Operating Manual
63
Installation and operation
Global Error indicator (orange)
–
Lights up orange
if a prefailure event has been detected that
requires (precautionary) service intervention.
–
Flashes orange
if an error was detected that requires service
intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator is activated
after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the Management Blade Web interface, on the
ServerView Local Service Panel, on the ServerView Local Service
Display, in the ServerView Operations Manager or via the
iRMC S2/S3's Web interface.
CSS
CSS indicator (yellow)
–
Lights up yellow
if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of
precaution) with the CSS concept.
–
Flashes yellow
if an error was detected that you can fix
yourself with the CSS concept.
–
Does not light up
when the system is OK.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
For more information on the CSS concept, see
"Customer Self
Service (CSS)" on page 13
.
ID
ID indicator (blue):
Glows blue when the system was selected by pressing the ID
button. Pressing the button again deactivates the LED.
The ID indicator can also be activated via the management blade
web interface and via the ServerView Operations Manager and its
status reported to the ServerView Operations Manager and the
iRMC S2/S3.
!