background image

UEFI Menu Operations 
3.1 Front page of Boot Manager 

 

549 

 

CA92344-0539-04 

 

FIGURE 3.2 Window area of Boot Manager Front Page 

 

 
 (1) Menu selection  
Displays selection menu shown in “

TABLE 3.1 Display item of menu selection

”. 

 
 

TABLE 3.1 Display item of menu selection 

Item 

Explanation 

Continue 

If you select ‘Continue’, boot is executed in the sequence that has 
presently been set. 

Boot Manager 

Displays “

3.3 [Boot Manager] Menu

 

Device Manager 

Displays “

3.4 [Device Manager] Menu

 

Boot Maintenance Manager 

Displays “

3.5 [Boot maintenance Manager] Menu

 

BIOS Boot Diagnotstic Test 

Executes BIOS Boot Diagnotstic Test. 
After execution, the power supply to the partition must be turned Off. 

 
 
(2) Operation help display part 
The help for operations mentioned on this page is shown in the “

TABLE 3.2 Display Items on Operation Help 

Display

 
 

TABLE 3.2 Display Items on Operation Help Display 

Item 

Description 



=Move Highlight 

Moves the cursor in up and down directions. 

<Enter> = Select Entry 

Selects the item. 

 

 

 

Summary of Contents for PRIMEQUEST 2000 Series

Page 1: ...CA92344 0539 04 FUJITSU Server PRIMEQUEST 2000 Series Tool Reference ...

Page 2: ...sed to manage and operate the PRIMEQUEST 2000 series server with the MMB Web UI It also describes how to use the MMB Web UI CHAPTER 2 MMB CLI Command Line Interface Operations Chapter 2 describes the CLI command line interface provided by the MMB CHAPTER 3 UEFI Menu Operations Chapter 3 describes the menu operations of the UEFI CHAPTER 4 UEFI Command Operations Chapter 4 describes the command oper...

Page 3: ...ure boot 03 2015 02 03 Chapter 2 Chapter 3 Correction of the error in writing 04 2015 05 01 All pages Added descriptions about Memory Scale up Board Added descriptions about Extended Socket Added descriptions about PRIMEQUEST 2400E2 2800E2 2800B2 models 1 Chapter section and item numbers in the Revised location column refer to those in the latest edition of the document However a number marked wit...

Page 4: ...t damage to the product or other property may occur if the user does not perform the procedure correctly This indicates information that could help the user use the product more efficiently Alert messages in the text An alert statement follows an alert symbol An alert statement is indented on both ends to distinguish it from regular text Similarly one space line is inserted before and after the al...

Page 5: ...nclude but are not limited to general office work personal and home use and general industrial use The product is not intended for applications that require extremely high levels of safety to be guaranteed referred to below as safety critical applications Use of the product for a safety critical application may present a significant risk of personal injury and or death Such applications include bu...

Page 6: ...a from hard disks when disposing of the product or transferring it Disposing of this product or transferring it as is may enable third parties to access the data on the hard disk and use it for unforeseen purposes To prevent the leakage of confidential information and important data all of the data on the hard disk must be erased before disposal or transfer of the product However it can be difficu...

Page 7: ...he error recurs contact your sales representative or a field engineer Confirm the model name and serial number shown on the label affixed to the right front of the device and report it Also check any other required items beforehand according to 12 2 Troubleshooting in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 The system settings saved by the customer will be used during mainten...

Page 8: ...des the necessary information and concepts you should understand for installation and facility planning for SPARC M10 Systems SPARC Enterprise and PRIMEQUEST installations C120 H007EN PRIMEQUEST 2000 Series Hardware Installation Manual Includes the specifications of and the installation location requirements for the PRIMEQUEST 2000 series CA92344 0535 PRIMEQUEST 2000 Series Installation Manual Des...

Page 9: ... ServerView Operations Manager Server Management Provides an overview of server monitoring using ServerView Operations Manager and describes the user interface of ServerView Operations Manager ServerView Suite ServerView RAID Management User Manual Describes RAID management using ServerView RAID Manager ServerView Suite Basic Concepts Describes basic concepts about ServerView Suite ServerView Oper...

Page 10: ...ft Windows Server 2012 R2 Datacenter Windows Windows Server 2012 Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 Standard Microsoft R Windows Server R 2008 R2 Standard Windows Windows Server 2008 R2 Microsoft R Windows Server R 2008 R2 Enterprise Microsoft R Windows Server R 2008 R2 Datacenter Red Hat R Enterprise Linux R 6 for Intel...

Page 11: ...rademarks of Novell Inc Xen is a trademark or registered trademark of Citrix Systems Inc or its subsidiaries in the United States and other countries Other company names and product names are the trademarks or registered trademarks of their respective owners Trademark indications are omitted for some system and product names in this manual Notation This manual uses the following fonts and symbols ...

Page 12: ...ve a comment or request regarding this manual or if you find any part of this manual unclear please take a moment to share it with us by filling in the form at the following webpage stating your points specifically and sending the form to us https www s fujitsu com global contact computing PRMQST_feedback html The contents of this manual may be revised without prior notice The PDF file of this man...

Page 13: ...personnel 65 1 1 13 Web UI menus PRIMEQUEST 2800B2 2800B model 67 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 70 1 2 1 System Status window 70 1 2 2 System Event Log Window 72 1 2 3 Operation Log Window 78 1 2 4 Partition Event Log Window 82 1 2 5 System Information Window 85 1 2 6 Firmware Information Window 87 1 2 7 System Setup Window 89 1 2 8 System Power Control window 92 1 2 9 L...

Page 14: ...1 3 9 1 Information Window 194 1 3 9 2 ASR Control Window 197 1 3 9 3 Console Redirection Window 200 1 3 9 4 Mode Window 202 1 4 User Administration Menu 208 1 4 1 User List window 208 1 4 1 1 Add User window 210 1 4 1 2 Edit User window 211 1 4 1 3 Remove User button 213 1 4 2 Change Password window 214 1 4 3 Who window 216 1 5 Network Configuration Menu 217 1 5 1 Date Time window 217 1 5 2 Netwo...

Page 15: ...Information Window 294 1 7 6 System Setup Window 296 1 7 7 Power Control Window 299 1 7 8 Schedule Menu 303 1 7 8 1 Schedule Control window 303 1 7 8 2 Schedule list Window 305 1 7 8 3 Add Schedule window Edit Schedule window 308 1 7 9 Console Redirection Setup Menu 311 1 7 9 1 IPv4 Console Redirection Setup window 311 1 7 9 2 IPv6 Console Redirection Setup window 312 1 7 10 Power Management Setup...

Page 16: ... 2 2 27 set partition memory_mirror_ras_mode 382 2 2 28 set partition memory_operation_mode 383 2 2 29 set partition name 385 2 2 30 set partition pci_address_mode 386 2 2 31 set partition pci_express_mode 387 2 2 32 set ssh 388 2 2 33 set ssh_port 388 2 2 34 set telnet 389 2 2 35 set telnet_port 389 2 2 36 set timezone 390 2 2 37 set partition extended_partitioning_mode 391 2 2 38 set partition d...

Page 17: ... raid rebuild 425 2 2 67 start raid copyback 426 2 2 68 cancel raid copyback 427 2 2 69 start raid mdc 428 2 2 70 cancel raid mdc 429 2 2 71 start raid patrol 430 2 2 72 cancel raid patrol 431 2 2 73 make raid online 432 2 2 74 make raid offline 433 2 2 75 replace raid missing_drive 434 2 3 Commands for Display 435 2 3 1 show access_control 436 2 3 2 show active_mmb 436 2 3 3 show date 437 2 3 4 s...

Page 18: ...dimm_excl_mode 465 2 3 40 show partition skt_binding_mode 466 2 3 41 show extended_partition configuration 467 2 3 42 show partition status 469 2 3 43 show partition extended_socket_mode 470 2 3 44 show partition extended_socket_zone 471 2 3 45 show partition memory_sparing_mode 472 2 3 46 show raid adapter 473 2 3 47 show raid disk_enclosure 475 2 3 48 show raid physical_drive 476 2 3 49 show rai...

Page 19: ... logical_drive 517 2 6 23 create raid global_hotspare 518 2 6 24 create raid dedicated_hotspare 519 2 6 25 delete raid hotspare 520 2 6 26 start raid locate_pd 521 2 6 27 stop raid locate_pd 522 2 6 28 start raid locate_ld 523 2 6 29 stop raid locate_ld 524 2 6 30 start raid locate_encl 525 2 6 31 stop raid locate_encl 526 2 6 32 start raid rebuild 527 2 6 33 cancel raid rebuild 528 2 6 34 start r...

Page 20: ...nu 572 3 4 4 2 I O SpaceAssignment Configuration Menu 581 3 4 5 iSCSI Configuration menu 583 3 4 5 3 MAC Selection Menu 588 3 4 5 4 Attempt Configuration Menu 590 3 4 5 5 DeleteAttempts Menu 594 3 4 5 6 ChangeAttempt Order menu 596 3 4 6 Memory Configuration menu 598 3 4 7 USB Configuration menu 600 3 4 8 Security Configuration menu 602 3 4 9 Secure Boot Configuration menu 605 3 4 9 1 Key Manageme...

Page 21: ... 1 1 2 Description 663 5 1 1 3 Options 663 5 1 1 4 Exit status 663 5 1 2 Device hot add hot remove operation add rm subcommand 664 5 1 2 1 Synopsis 664 5 1 2 2 Description 664 5 1 2 3 Options 664 5 1 2 4 Example 664 5 1 3 Show slot status slot subcommand 665 5 1 3 1 Synopsis 665 5 1 3 2 Description 665 5 1 3 3 Options 665 5 1 3 4 Example 665 5 1 4 Show resources on device show subcommand 666 5 1 4...

Page 22: ...tem of Operation Log Filtering Condition Window 699 A 1 3 Setting Item of Partition Event Log Filtering Condition Window 699 A 1 4 Setting Items of System Information Window 700 A 1 5 Setting items of System Setup Window 700 A 1 6 Setting items of System Power Control Window 701 A 1 7 Setting items of Power Control Window 701 A 1 8 Setting Items of Schedule Control Window 701 A 1 9 Setting Items o...

Page 23: ...A 2 1 Setting Items on LAN Remote Boot Configuration Window 720 A 2 2 Setting Items on CPU Configuration Window 721 A 2 3 Setting Items on PCI Subsystem Configuration Window 722 A 2 3 1 Setting Items on OpROM Scan Configuration Window 724 A 2 3 2 Setting Items on I O SpaceAssignment Configuration Window 726 A 2 4 Setting Items on iSCS Configuration Window 727 A 2 4 1 Setting Items on Attempt Confi...

Page 24: ...01 FIGURE 1 18 SB x Window 1 103 FIGURE 1 19 SB x Window 2 104 FIGURE 1 20 SB x Window 3 104 FIGURE 1 21 SB x Window 4 105 FIGURE 1 22 SB x Window 5 105 FIGURE 1 23 SB x Window 6 106 FIGURE 1 24 Memory Scale up Board Window 1 107 FIGURE 1 25 Memory Scale up Board Window 2 107 FIGURE 1 26 Memory Scale up Board Window 3 108 FIGURE 1 27 Memory Scale up Board Window 4 108 FIGURE 1 28 Memory Scale up B...

Page 25: ...of SB Resources no Extended Partitioning window 179 FIGURE 1 63 Extended Partition Configuration of IOU Resources Window 180 FIGURE 1 64 Extended Partition Configuration of IOU Resources no EXTENDED PARTITIONING windows 181 FIGURE 1 65 Extended Partition Configuration of PCI_Box Resources windows 182 FIGURE 1 66 Extended Partition Configuration of PCI_Box Resources no Extended Partitioning Window ...

Page 26: ...ow 264 FIGURE 1 108 Add Filter window 266 FIGURE 1 109 Alarm E Mail window 268 FIGURE 1 110 Alarm E Mail Filtering Condition window PRIMEQUEST 2400E2 2800E2 2400E 2800E 270 FIGURE 1 111 Alarm E Mail Filtering Condition window PRIMQUEST 2800B 271 FIGURE 1 112 Unified Firmware Update window 273 FIGURE 1 113 Backup Restore MMB Configuration window 275 FIGURE 1 114 Backup BIOS Configuration window 277...

Page 27: ... Legacy Net Drive Order Menu 564 FIGURE 3 14 Display Example of CPU Configuration Menu 565 FIGURE 3 15 Display Example of CPU Configuration Menu PRIMEQUEST 2400E2 2800E2 2800B2 565 FIGURE 3 16 Display Example on PCI Subsystem Configuration Menu 570 FIGURE 3 17 Display Example of OpROM Scan Configuration Menu 572 FIGURE 3 18 Display example of I O Space Assignment Configuration Menu 581 FIGURE 3 19...

Page 28: ...y Level Set Legacy HardDisk Drive Order 2 636 FIGURE 3 55 Change in Priority Level Set Legacy HardDisk Drive Order 3 637 FIGURE 3 56 Change in Priority Level Set Legacy HardDisk Drive Order 4 638 FIGURE 3 57 Example of Displayed Set Legacy CD ROM Drive Order Menu 639 FIGURE 3 58 Change in priority level Set Legacy CD ROM Drive Order 1 641 FIGURE 3 59 Change in priority level Set Legacy CD ROM Driv...

Page 29: ...sadump configuration 683 FIGURE 6 5 Main menu 684 FIGURE 6 6 sadump setup menu 685 FIGURE 6 7 Dump device maintenance menu 687 FIGURE 6 8 Dump device create menu 688 FIGURE 6 9 Dump device select menu 689 FIGURE 6 10 Setting dump device Menu 691 FIGURE 6 11 Select device Menu 693 FIGURE 6 12 Select discard dump device Menu 694 FIGURE 6 13 Select discard dump device Menu Select multiple devices Men...

Page 30: ...ns 77 TABLE 1 21 Display items of Operation Log window 78 TABLE 1 22 Operation Log Window Buttons 79 TABLE 1 23 Display and Set Items of Operating Log Filtering Condition Window 81 TABLE 1 24 Buttons on Operation Log Filtering Condition window 81 TABLE 1 25 Display items of Partition Event Log window 82 TABLE 1 26 Partition Event Log Window Buttons 82 TABLE 1 27 Display and Set Items of Partition ...

Page 31: ...64 TABLE 1 67 IPv6 Console redirection Setup Window Buttons 164 TABLE 1 68 Display Items and Set Items of Add Schedule Window 167 TABLE 1 69 Partition Configuration Window Buttons 167 TABLE 1 70 Display Items and Set Items of Add SB IOU to Partition Window 169 TABLE 1 71 Display Items and Set Items of Remove SB IOU to partition Window 172 TABLE 1 72 Allocation granularity of Memory by Memory Opera...

Page 32: ... Network Protocols window 240 TABLE 1 106 Buttons in the Network Protocols window 241 TABLE 1 107 Setting and display items in the Refresh Rate window 242 TABLE 1 108 Buttons in the Refresh Rate window 242 TABLE 1 109 Setting and display items in the SNMP Community window 245 TABLE 1 110 Buttons in the SNMP Community window 245 TABLE 1 111 Setting and display items in the SNMP Trap window 247 TABL...

Page 33: ...ems of Schedule Control Window 304 TABLE 1 151 Schedule Control Window Buttons 304 TABLE 1 152 Display Items and Set Items of Schedule List Window 306 TABLE 1 153 Schedule List Window Buttons 307 TABLE 1 154 Display Items and Set Items of Add Schedule Window 309 TABLE 1 155 Add Schedule Window Buttons 309 TABLE 1 156 Display Items and Set Items of IPv4 Console redirection Setup Window 311 TABLE 1 ...

Page 34: ...the System Information Display 559 TABLE 3 13 Display Contents of Help Operation Display 559 TABLE 3 14 Reflection of LAN Remote Boot Configuration Menu 560 TABLE 3 15 Display contents of Menu Selection 561 TABLE 3 16 Display contents of Display of Operation help 561 TABLE 3 17 Display Contents of Menu Selection 566 TABLE 3 18 Display Contents of Operation Help Display 569 TABLE 3 19 Display Conte...

Page 35: ...E 3 58 Display contents of Menu selection 614 TABLE 3 59 Display contents of Display of operation help 615 TABLE 3 60 Display contents of Display of Operation help 616 TABLE 3 61 Number of Characters and Types of Characters that can be entered 621 TABLE 3 62 Display contents of operation help display 622 TABLE 3 63 Display Contents of Menu Selection 625 TABLE 3 64 Display Contents of Operation Hel...

Page 36: ...ation 693 TABLE 6 15 Displayed contents of menu selection area 694 TABLE 6 16 Displayed contents of the help display area for operation 694 TABLE 6 17 Displayed contents of menu selection area 695 TABLE 6 18 Displayed contents of the help display area for operation 695 TABLE 6 19 Displayed contents of menu selection area 696 TABLE 6 20 Displayed contents of the help display area for operation 696 ...

Page 37: ...ms of Alarm E Mail Window 718 TABLE A 33 Setting Items of Alarm E Mail Filtering Condition Window 719 TABLE A 34 Setting Items of LAN Remote Boot Configuration Window 720 TABLE A 35 Setting Items of CPU Configuration Window 721 TABLE A 36 Setting Items of PCI Subsystem Configuration Window 722 TABLE A 37 Setting Items of OpROM Scan Configuration Window 1 2 724 TABLE A 38 Setting Items of OpROM Sca...

Page 38: ...ave the same privileges as Operator accounts except that their privileges are restricted to specific partitions Like Operator accounts they are permitted to check the system status Unlike Operator accounts they are not permitted to perform some operations such as clearing the status of an SB IOU User User accounts are only permitted to check the PRIMEQUEST 2000 series server status They are not pe...

Page 39: ...ormation RW Displays system information such as the system name or product name Firmware Information RO Displays firmware version information System Setup RW Sets the system configuration System Power Control RW Controls the power LEDs RW Displays the LED status Power Supply RW Displays the power supply status Fans RW Displays the fan status Temperature RO Displays the temperatures detected by the...

Page 40: ...d Partition Configuration Changes the Extended Partitioning configuration When Extended Partitioning Mode is Disable this menu is not displayed SB RW IOU n RW PCI_Box n RW Extended Socket Configuration RW Sets concerning Extended Socket Zone setting Reserved SB Configuration RW Defines a Reserved SB Power Management Setup RW Partition 0 If no board belongs to the partition this submenu is not disp...

Page 41: ...ret key and CSR Export Key CSR RW Exports a secret key and CSR Import Certificate RW Installs a certificate Create Selfsigned Certificate RW Creates a selfsigned certificate SSH SSH Server Key RW Creates a private key for the SSH server Remote Server Management RW Access Control RW Sets the IP filtering that permits connections Alarm E mail RW Maintenance Firmware Update Unified Firmware Update RW...

Page 42: ...ame Firmware Information RO Displays firmware version information System Setup RO Sets the system configuration System Power Control RO Controls the power LEDs RW Displays the LED status Power Supply RO Displays the power supply status Fans RO Displays the fan status Temperature RO Displays the temperatures detected by the temperature sensors of the PRIMEQUEST 2000 series system SB SB 0 RW Display...

Page 43: ...CI_Box n RO Extended Socket Configuration RO Sets concerning Extended Socket Zone setting Reserved SB Configuration RO Defines a Reserved SB Power Management Setup RO Partition 0 If no board belongs to the partition this submenu is not displayed Information RO Displays the partition status and partition related information ASR Control RO Sets the conditions for automatically restarting the partiti...

Page 44: ... a certificate Create Selfsigned Certificate N A Creates a selfsigned certificate SSH SSH Server Key N A Creates a private key for the SSH server Remote Server Management N A Access Control N A Sets the IP filtering that permits connections Alarm E mail N A Maintenance Firmware Update Unified Firmware Update N A Performs a batch update Backup Restore Configuration Backs up and restores setting inf...

Page 45: ... System Event Log RO RO Displays system event logs Operation Log RO RO Displays the operations on the Web UI and CLI Partition Event Log RO RO Displays the REMCS notification messages of a PRIMEQUEST partition System Information RO RO Displays system information such as the system name or product name Firmware Information RO RO Displays firmware version information System Setup RO RO Sets the syst...

Page 46: ...2 RO RO PCI_Box 3 RO RO OPL RO RO MMB MMB 0 RO RO Displays the MMB status and information MMB 1 RO RO Disk Enclosure If no Disk Enclosure is connected this menu is not displayed Disk Enclosure x RO RO The menu is not displayed for an unmounted Disk Enclosure Partition Power Control RW RO Controls the partition power Schedule Schedule Control RW RO Sets scheduled operations Schedule List RW RO Sets...

Page 47: ...longs to the partition this submenu is not displayed Information RO N A Displays the partition status and partition related information ASR Control RW N A Sets the conditions for automatically restarting the partition Console Redirection RW N A Displays the console output of the partition Mode RW N A Sets the mode for the partition Partition 1 Same as for Partition 0 Partition 2 Partition 3 User A...

Page 48: ...rts a secret key and CSR Import Certificate N A N A Installs a certificate Create Selfsigned Certificate N A N A Creates a selfsigned certificate SSH SSH Server Key N A N A Creates a private key for the SSH server Remote Server Management N A N A Access Control N A N A Sets the IP filtering that permits connections Alarm E mail N A N A Maintenance Firmware Update Unified Firmware Update N A N A Pe...

Page 49: ...e or product name Firmware Information RO Displays firmware version information System Setup RO Sets the system configuration System Power Control RO Controls the power LEDs RW Displays the LED status Power Supply RO Displays the power supply status Fans RO Displays the fan status Temperature RO Displays the temperatures detected by the temperature sensors of the PRIMEQUEST 2000 series system SB S...

Page 50: ...isplayed SB RO IOU n RO PCI_Box n RO Extended Socket Configuration RO Sets concerning Extended Socket Zone setting Reserved SB Configuration RO Defines a Reserved SB Power Management Setup RO Partition 0 If no board belongs to the partition this submenu is not displayed Information RO Displays the partition status and partition related information ASR Control RO Sets the conditions for automatical...

Page 51: ...talls a certificate Create Selfsigned Certificate N A Creates a selfsigned certificate SSH SSH Server Key N A Creates a private key for the SSH server Remote Server Management N A Access Control N A Sets the IP filtering that permits connections Alarm E mail N A Maintenance Firmware Update Unified Firmware Update N A Performs a batch update Backup Restore Configuration Backs up and restores settin...

Page 52: ... information such as the system name or product name Firmware Information RO Displays firmware version information System Setup RW Sets the system configuration System Power Control RO Controls the power LEDs RW Displays the LED status Power Supply RW Displays the power supply status Fans RW Displays the fan status Temperature RO Displays the temperatures detected by the temperature sensors of the...

Page 53: ... Configuration Changes the Extended Partitioning configuration When Extended Partitioning Mode is Disable this menu is not displayed SB RO IOU n RO PCI_Box n RO Extended Socket Configuration RO Sets concerning Extended Socket Zone setting Reserved SB Configuration RO Defines a Reserved SB Power Management Setup RO Partition 0 If no board belongs to the partition this submenu is not displayed Infor...

Page 54: ...et key and CSR Export Key CSR N A Exports a secret key and CSR Import Certificate N A Installs a certificate Create Selfsigned Certificate N A Creates a selfsigned certificate SSH SSH Server Key N A Creates a private key for the SSH server Remote Server Management N A Access Control N A Sets the IP filtering that permits connections Alarm E mail N A Maintenance Firmware Update Unified Firmware Upd...

Page 55: ...This work can be performed without stopping application software Warm System Maintenance Target unit in a powered off partition Partition stopped for work For maintenance work on the partition under maintenance or the partition containing the target maintenance unit The partition must be stopped during maintenance The partitions not under maintenance need not be stopped Cold System Maintenance All...

Page 56: ...the menu and submenu 1 The account user can operate partitions not in maintenance mode in this window 2 The account user can operate only partitions in maintenance mode in this window 3 The SB is neither a Home SB nor Reserved SB Alternatively the SB is the Home SB in the Power Off status in a partition in the Standby status 4 The partition is in the Standby status TABLE 1 8 Web UI menus in mainte...

Page 57: ...ystem RW 1 Cold System RO Console Redirection Hot System RW Hot Partition RW 1 Warm System RW 1 Cold System RO Network Configuration Network Interface IPv4 Interface Hot System RO Hot Partition RO IPv6 Interface Warm System RO Cold System RO Maintenance Firmware Update Unified Firmware Update Hot System RO Hot Partition RO Warm System RO Cold System RO Backup Restore Configuration Backup Restore M...

Page 58: ...The account user can operate partitions not in maintenance mode in this window 2 The account user can operate only partitions in maintenance mode in this window 3 The SB is neither a Home SB nor Reserved SB Alternatively the SB is the Home SB in the Power Off status in a partition in the Standby status 4 The partition is in the Standby status TABLE 1 9 Web UI menus in maintenance mode Operator Nav...

Page 59: ...m RO Cold System RO Console Redirection Hot System RW Hot Partition RW 1 Warm System RW 1 Cold System RO Network Configuration Network Interface IPv4 Interface Hot System RO Hot Partition RO IPv6 Interface Warm System RO Cold System RO Maintenance Firmware Update Unified Firmware Update Hot System N A Hot Partition N A Warm System N A Cold System N A Backup Restore Configuration Backup Restore MMB...

Page 60: ... partitions not in maintenance mode in this window 2 The account user can operate only partitions in maintenance mode in this window 3 The SB is neither a Home SB nor Reserved SB Alternatively the SB is the Home SB in the Power Off status in a partition in the Standby status 4 The partition is in the Standby status TABLE 1 10 Web UI menus in maintenance mode Partition Operator Navigation bar 1st l...

Page 61: ...System RO RO Cold System RO RO Console Redirection Hot System RW N A Hot Partition RW 1 N A Warm System RW 1 N A Cold System RO N A Network Configuration Network Interface IPv4 Interface Hot System RO RO Hot Partition RO RO IPv6 Interface Warm System RO RO Cold System RO RO Maintenance Firmware Update Unified Firmware Update Hot System N A N A Hot Partition N A N A Warm System N A N A Cold System ...

Page 62: ...er cannot view the menu and submenu 1 The account user can operate partitions not in maintenance mode in this window 2 The account user can operate only partitions in maintenance mode in this window 3 The SB is neither a Home SB nor Reserved SB Alternatively the SB is the Home SB in the Power Off status in a partition in the Standby status 4 The partition is in the Standby status TABLE 1 11 Web UI...

Page 63: ...Hot Partition RO Warm System RO Cold System RO Console Redirection Hot System N A Hot Partition N A Warm System N A Cold System N A Network Configuration Network Interface IPv4 Interface Hot System RO Hot Partition RO IPv6 Interface Warm System RO Cold System RO Maintenance Firmware Update Unified Firmware Update Hot System N A Hot Partition N A Warm System N A Cold System N A Backup Restore Confi...

Page 64: ... view the menu and submenu 1 The account user can operate partitions not in maintenance mode in this window 2 The account user can operate only partitions in maintenance mode in this window 3 The SB is neither a Home SB nor Reserved SB Alternatively the SB is the Home SB in the Power Off status in a partition in the Standby status 4 The partition is in the Standby status TABLE 1 12 Web UI menus in...

Page 65: ...tem RO Hot Partition RO Warm System RO Cold System RO Console Redirection Hot System RO Hot Partition RO Warm System RO Cold System RO Network Configuration Network Interface IPv4 Interface Hot System RO Hot Partition RO IPv6 Interface Warm System RO Cold System RO Maintenance Firmware Update Unified Firmware Update Hot System RO Hot Partition RO Warm System RO Cold System RO Backup Restore Config...

Page 66: ... partitions not in maintenance mode in this window 2 The account user can operate only partitions in maintenance mode in this window 3 The SB is neither a Home SB nor Reserved SB Alternatively the SB is the Home SB in the Power Off status in a partition in the Standby status 4 The partition is in the Standby status TABLE 1 13 Web UI menus in maintenance mode maintenance personnel Navigation bar 1s...

Page 67: ... Cold System RW RO Console Redirection Hot System RW RO Hot Partition RW 1 RO Warm System RW RW 2 Cold System RW RW Network Configuration Network Interface IPv4 Interface Hot System RO RO Hot Partition RO RO IPv6 Interface Warm System RO RO Cold System RO RO Maintenance Firmware Update Unified Firmware Update Hot System RW RW Hot Partition RO RO Warm System RO RO Cold System RW RW Backup Restore C...

Page 68: ...ion RW RO RO RO Displays system information such as the system name or product name Firmware Information RO RO RO RO Displays firmware version information System Setup RW RO RO RW Sets the system configuration Power Control RW RW RO RO Controls the power Schedule Schedule Control RW RW RO RO Sets scheduled operations Schedule List RW RW RO RO Sets the power on off schedule Console Redirection Setu...

Page 69: ...O RW MMB RW RW RO RW User Administration User List RW N A N A N A Lists edits and deletes registered user accounts Change Password RW RW RW RW Changes the password of the user s own account Who RO RO RO RO Displays all users who are logged in to the MMB Network Configuration Date Time RW RO RO RO Network Interface RW RO RO RO IPv4 Interface RW RO RO RO Sets the IPv4 IP address etc IPv6 Interface R...

Page 70: ...SH server Remote Server Management RW N A N A N A Access Control RW N A N A N A Sets the IP filtering that permits connections Alarm E mail RW N A N A N A Maintenance Firmware Update Unified Firmware Update RW N A N A RW Performs a batch update Backup Restor e Configuration Backs up and restores setting information Backup Rest ore MMB Configuratio n RW N A N A RW Backup Rest ore BIOS Configuratio ...

Page 71: ... model name and serial number shown on the label affixed on the main unit and report it 1 2 1 System Status window System Status window shows the status of entire PRIMEQUEST 2000 series system The contents displayed may differ depending on the configuration of the unit You can also display details of each unit by clicking the link displayed in the frame FIGURE 1 1 System Status window The contents...

Page 72: ...SU Fans Shows the status of FAN Temperature Shows the status of temperature sensor SB 0 SB 3 Shows the status of system board In case of PRIMEQUEST 2400E2 2400E model it is SB 0 SB 1 1 IOU 0 IOU 3 Shows the status of IOU DU 0 DU 1 Shows the status of DU OPL Shows the status of OPL MMB 0 MMB 1 Shows the status of MMB PCI_Box 0 PCI_Box 3 Shows the status of PCI_Box which are connected 1 The state of...

Page 73: ...yed on the System Event Log window in chronological order Maximum 32000 events can be stored in system event log When the entries in the system event log are full oldest event log is deleted and latest event log is stored in system event log FIGURE 1 2 System Event Log window In the System Event Log Window only the contents and not the title in the table can be scrolled When there are no events to...

Page 74: ...QUEST 2000 Series Message Reference CA92344 0540CA92344 0540 Description Displays the contents of Events and Errors Remarks For the event of insertion removal of the board part number and serial number of board are displayed TABLE 1 18 Buttons on System Event Log Window Buttons Description Clear All Events When you click Clear All Events button all the events saved in system event log are cleared ...

Page 75: ...button Progress window appears while the system event log information is collected 4 System Event Log Collect window appears and the link to event data which is collected is displayed with date information When you click the link a dialog box appears By specifying the file name and path name event data can be downloaded to the PC which displays Web UI FIGURE 1 3 System Event Log Collect Window Nar...

Page 76: ...tion Window Click Filter button on the System Event Log window The System Event Log Filtering Condition window for entering filtering conditions appears The filtering conditions of events which are displayed in System Event Log window can be set in the System Event Log Filtering Condition window FIGURE 1 4 System Event Log Filtering Condition Window ...

Page 77: ...pecified and Partition to be managed is turned on Other than the above All Remarks Specify both CPU and Chipset when filtering as Source with the unit of CPU Unit Select the target unit to be displayed Select All or Specified by Radio button All Filtering is not done by Unit Specified Filtering of Unit can be set Select the Source to be displayed Default setting is All Source Select target source ...

Page 78: ...setting is 100 events TABLE 1 20 System Events Log Filtering Condition Window Buttons Buttons Description Apply Log which matches with the specified conditions will be listed on System Event Log window by clicking the Apply button Cancel Returns to System Event Log window by clicking the Cancel button Default Setting Selected value returns to the default value Message This section describes the me...

Page 79: ...escription Date Time Displays the local time of occurrence of the event or error Format YYYY MM DD HH MM SS Operation Displays the source Web UI CLI or RMCP and contents of the operation IP Address Displays the source IP address IPv4 or IPv6 address of the operation This column displays Console for a CLI operation performed on a console with serial connection If the host name can be identified fro...

Page 80: ...dow Operations When the entire operation log is to be cleared 1 Click Clear button A dialog box is displayed for confirmation 2 Click OK button to clear operation log Click Cancel button when you do not want to clear operation log Narrowing down the operation log displayed in the window 1 Click the Filter button The Operation Log Filtering Condition window for entering filtering conditions appears...

Page 81: ...ng Condition Window When Filter button on the Operation Log window is clicked the Operation Log Filtering Condition window for entering filtering conditions appeared Filtering conditions of event which appears on Operation Log window can be set on Operating Log Filtering Condition Window FIGURE 1 6 Operating Log Filtering Condition Window ...

Page 82: ...using radio button either display from the last event or time specified event Last event Set to last event Specified Time Set to specified time If Specified Time is selected enter the date and time of end time By default it is Last event Number of events to display Specifies the number of log to be displayed For the denominator part the total number of logged in events is displayed It is specified...

Page 83: ...ms like hardware damage Warning Though it is not severe problems may occur in the future for events Information Event assumed as information when partition power is on Date Time Displays the time when event and errors occurs Format YYYY MM DD HH MM SS Partition No Displays the partition number Unit Displays the unit which has the event or error detected sensor Event ID Displays the ID 8 digit hexa...

Page 84: ...tition Event Log window Events satisfying the specified conditions appear When the partition event log is to be cleared 1 Click the Clear button A dialog box for confirmation appears 2 Click the OK button if the partition log event is to be cleared Else click the Cancel button Partition Event Log Filtering Condition Window When Filter button on the Partition Event Log is clicked Partition Event Lo...

Page 85: ...s the number of logs to be displayed The denominator represents the total number of logged events Maximum 1000 events can be displayed The default setting is100 TABLE 1 28 Buttons on the Partition Event Log Filtering Condition Window Buttons Description Apply When Apply button is clicked the log corresponding to the conditions specified is displayed on the Partition Event Log screen Cancel Returns...

Page 86: ...nformation Window System Information window displays the information such as name of the systems and name of the products etc related to the PRIMEQUEST 2000 Series System Moreover names and Asset Tag Property management number corresponding to the PRIMEQUEST 2000 Series System Chassis can be set FIGURE 1 9 System Information Window ...

Page 87: ...T 2000 series is displayed Asset Tag Property administration information Asset Tag is displayed User with the administrator privilege can change Asset Tag information Maximum 32 characters can be entered No default value TABLE 1 30 Buttons on the System Information Window Buttons Description Apply When the characters are entered in the System Name or Asset Tag fields and click the Apply button is ...

Page 88: ...2344 0539 04 1 2 6 Firmware Information Window Latest version number of applied Firmware information of the Firmware version which is operating inside the system and the information of the Firmware version with backup is displayed on the Firmware Information window FIGURE 1 10 Firmware Information Window ...

Page 89: ...inor Version 1Byte data BCD format This data is displayed as follows X YY X displays Major version in decimal 0 255 Y displays Minor version as it is by double digit in BCD format Binary coded decimal 00 99 Version bank2 Firmware Version of bank2 is displayed Version display format Same as bank1 Unified Firmware version Displays firmware version of target unit Firmware maintains version informatio...

Page 90: ...ions 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 89 CA92344 0539 04 1 2 7 System Setup Window In System Setup window Power supply of PRIMEQUEST 2000 system and restoration action etc can be set FIGURE 1 11 System Setup Window ...

Page 91: ...erations at the time of restoration of power attention The schedule set with Special is applied only on the specified day Default setting is Restore Partition Power On Delay Sets the standby time utill power on of partition is specified as per the restoration power policy that is set after the AC power is On also includes restoration power This item becomes effective at the time of the Power ON by...

Page 92: ... out at the time of disable Default value is the maximum value of each model TABLE 1 33 System Setup window button Buttons Description Apply When items such as Power Feed Mode and Power Restore Policy are specified and Apply button is clicked the information is set Cancel When Cancel button is clicked returns to the original status without setting the changed or input items 1 Menu Operation System...

Page 93: ...he main unit and report it Moreover do not Reset or Force Power Off the partition till the error is solved When Power off Reset Force Power Off and shut down of partition is done by operating system and if the state of each component on the MMB Web UI screen is displayed in the state in which processing does not end even for a long time Part Number and Serial Number are displayed as Read Error FIG...

Page 94: ... Release maintenance mode E_00077 Partition xx cannot execute Power On E_00078 Partition xx cannot execute Power Off E_00100 Failed to set the System Power Control E_00101 Unable to power on the partition aa due to CPU mismatch between SBs E_00107 Unable to power on the chassis E_00108 Unable to power off the chassis E_00109 Unable to force power off I_00212 System Power Control cannot be executed...

Page 95: ... of the LED in the system FIGURE 1 13 LEDs Window Displays Not present for the units which are not installed background color of those rows is displayed in gray color Following is displayed only in case of PRIMEQUEST 2400E2 2400E model SB SB 0 SB 1 Remarks The state of SB 0 SB 3 is displayed for PRIMEQUEST 2400E2 Model in the case that Memory Scale up Board is used ...

Page 96: ... normal or abnormal Location LED Displays sets the Location LED status of unit TABLE 1 37 LEDs Window Button Buttons Description On When On button is clicked Location LED is turned on Off When Off button is clicked Location LED is turned off Turn off all Location LEDs When Turn off all Location LEDs button is clicked all Location LED in system are turned off 1 Menu Operation System LEDs 2 Window O...

Page 97: ... 2 10 Power Supply window Power Supply window displays the PSU status in the PRIMEQUEST 2000 series Once the error in the status of each PSU is detected the abnormality status is maintained till the PSU is replaced or the abnormality status is cleared by clicking the Status Clear button FIGURE 1 14 Power Supply Window ...

Page 98: ... status of PSU FANU OK Not present Failed A C Lost Configuration error When Type is FANU Power Status Displays power supply ON OFF status of PSU FANU On Off When Type is FANU Type Displays the types of PSU FANU PSU_P PSU supporting 80PLUS PLATINUM PSU_S PSU supporting 80PLUS SILVER FANU Module of FAN only For Not present Mixing of PSU_P PSU_S in the same component is not possible Part Number Displ...

Page 99: ... CA92344 0539 04 Message This section describes the messages to be displayed on this window Message Number Message I_00029 Status Clear completed E_00123 Failed to clear the status For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540CA92344 0540 ...

Page 100: ... System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 99 CA92344 0539 04 1 2 11 Fans window Fans window displays the Fan status in PRIMEQUEST 2000 Series System and clears the Fan status setting FIGURE 1 15 Fans Window 1 FIGURE 1 16 Fans Window 2 ...

Page 101: ...ongs FANM Displays the FANM FAN Module installed in PSU FANU Slot Part Number Displays the part number of the fan Status Displays the status of each fan OK Not present Warning Failed Fan Speed rpm Displays the rotational frequency rpm of each fan Threshold rpm Warning Low High Displays the lower limit and upper limit of the warning level rotational frequency of each fan If the rotational frequency...

Page 102: ...Temperature Window displays the temperature of the temperature sensor of PRIMEQUEST 2000 series system In case of PRIMEQUEST 2400E2 2400E model only the following items are displayed SB SB 0 SB 1 Remarks The state of SB 0 SB 3 is displayed for PRIMEQUEST 2400E2 Model in the case that Memory Scale up Board is used FIGURE 1 17 Temperature Window ...

Page 103: ...l Temperature Displays the temperature of each temperature sensor Threshold Warning Low High Displays the lower limit and upper limit of the warning level temperature of each sensor If the temperature is lower or upper than this limit it is considered to be abnormal Critical Low High Displays the lower limit and upper limit of the critical level temperature of each sensor If the temperature is low...

Page 104: ...he menu of uninstalled SB is not displayed The format of window and operating method are same for each menu therefore only one menu is explained here Information on Memory Scale up Board is displayed on this screen in the case of PRIMEQUEST 2400E2 SB x Window SB x window displays the status of SB x board and the settings of SB x board can be carried out FIGURE 1 18 SB x Window 1 ...

Page 105: ...MMB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 104 CA92344 0539 04 FIGURE 1 19 SB x Window 2 FIGURE 1 20 SB x Window 3 ...

Page 106: ...MMB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 105 CA92344 0539 04 FIGURE 1 21 SB x Window 4 FIGURE 1 22 SB x Window 5 ...

Page 107: ...nd a message Click the Status Clear Button to clear the status are not displayed for a user who does not have setting privileges When System Progress of the partition is EFI Boot and OS Running various information on RAID Card Physical Drives Logical Drives and the Action Progress table is displayed After System Progress is changed into the state of EFI Boot and OS Running until information is cor...

Page 108: ...MB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 107 CA92344 0539 04 FIGURE 1 24 Memory Scale up Board Window 1 FIGURE 1 25 Memory Scale up Board Window 2 ...

Page 109: ...MB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 108 CA92344 0539 04 FIGURE 1 26 Memory Scale up Board Window 3 FIGURE 1 27 Memory Scale up Board Window 4 ...

Page 110: ...MMB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 109 CA92344 0539 04 FIGURE 1 28 Memory Scale up Board Window 5 ...

Page 111: ...t Home status or not Yes Home status No Not a Home status Part Number Displays the part number of the SB Serial Number Displays the serial number of the SB Location LED Indicates the display status of the Location LED The display status consists of the following conditions On The light is on Off The light is off On Off and blinking of the Location LED can be controlled by clicking the respective O...

Page 112: ...a Rate of DIMM DDR3 1066 1333 1600 For PRIMEQUEST 2400E 2800E 2800B DDR4 1333 1600 1866 For PRIMEQUEST 2400E2 2800E2 2800B There is no display when the DIMM status is Not present Not supported or Unknown Part Number Displays the part number of DIMM There is no display when the DIMM status is Not present Not supported or Unknown Serial Number Displays the serial number of DIMM There is no display w...

Page 113: ... For details of the ID see the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 Physical Drives Count The number of physical drives connected with RAID Card is displayed Logical Drives Count The number of logical drives composed under the control of RAID Card is displayed Serial Number The serial number of RAID Card is displayed Firmware Version The firmware version of RAID Card is displa...

Page 114: ... Sensor from which the RAID action is executed is shown when Drive Type is Logical Action The RAID action under execution is displayed Rebuilding It is shown for a physical drive to execute the rebuild of the RAID drive Copyback Running It is shown for a physical drive to execute the copy backing MDC Running It is shown for a logical drive to execute MDC Make Data Consistent Progress The progress ...

Page 115: ...1 0V_JC 0A P1 5V_PCH P1 1V P0 9V_PCIEX 0 P1 8V_PCIEX 0 P0 9V_PCIEX 1 P1 8V_PCIEX 1 P12V 0 P5V P3 3V P1 35V_CPU 0 P1 35V_CPU 1 VCC_CPU 0 VSA_CPU 0 VTT_CPU 0 VDDQ_DIMM 0A VDDQ_DIMM 0B P1 0V_JC 0B P1 5V_JC 0AB P1 35V_JC 0AB VCC_CPU 1 VSA_CPU 1 VTT_CPU 1 VDDQ_DIMM 1B P1 0V_JC 1A P1 0V_JC 1B P1 5V_JC 1AB P1 35V_JC 1AB VDDQ_DIMM 0C VDDQ_DIMM 0D P1 0V_JC 0C P1 0V_JC 0D P1 5V_JC 0CD P1 35V_JC 0CD VDDQ_DIM...

Page 116: ... 0D P1 05V_JC 0CD P1 5V_JC 0CD P1 35V_JC 0CD VDDQ_DIMM 1C VDDQ_DIMM 1D P1 05V_JC 1CD P1 5V_JC 1CD P1 35V_JC 1CD P2 5V_DIMM 0AB P2 5V_DIMM 1AB P2 5V_DIMM 0CD P2 5V_DIMM 1CD P12V 1 P12V 2 P12V 3 P12V 4 P12V 0F Voltage Displays the current power voltage Threshold Warning Low High Lower and upper limits of the warning level voltage Displays when the threshold is not set Displays the power voltage in t...

Page 117: ... ON Off When the Off button is clicked the Location LED is OFF Status Clear Clears the status of the SB Message This section describes the messages to be displayed on this window Message Number Message I_00029 Status Clear completed E_00048 The specified unit is not installed E_00123 Failed to clear the status For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message R...

Page 118: ...hen the error status of that such component is registered again When the check box of Clear Status of common parts is checked things except CPU DIMM Chipset system are cleared FIGURE 1 29 SB x Status Clear Window Message Display 1 Menu Operation System SB SB x Status Clear button 2 Window Operations 1 Specify as given below to clear the component Select Clear All Status to clear all the components...

Page 119: ...s the Partition start At that time the following messages are displayed on the table of the composition display of CPU or DIMM respectively to make CPU or any DIMM easy to recognize not installed as follows by the deficit and the boldface character It is necessary to install at least one CPU in SB x In case of CPU It is necessary to install at least one DIMM set per one DIMM in SB x In case of DIM...

Page 120: ... IOU IOU 0 IOU 3 The menu is not displayed for the IOU which is not installed Since the window and the operating method are same for each menu only one menu is described here IOU x Window IOU x window displays the status of the IOU installed in IOU x slot In addition IOU can be set FIGURE 1 31 IOU x Window 1 PCI_Box connection is available for PRIMEQUEST 2800E2 2800E and 2400E2 2400E ...

Page 121: ...User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 120 CA92344 0539 04 FIGURE 1 32 IOU x Window 2 The displays other than PCI_Box connection do not depend on the model and are the same ...

Page 122: ...MMB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 121 CA92344 0539 04 FIGURE 1 33 IOU x Window 3 ...

Page 123: ...en MAC Address is not clear PCI_Box connection PCI_Box connection is not displayed in the case of PRIMEQUEST 2800B2 2800B PCIC Displays PCIC for PCI_Box connection on the IOU Status Displays the status of connection with the PCI_Box OK Not connected Incorrect connection Connected to PCI_Box Displays the destination PCI_Box When not connected background color is displayed in gray color Connector Di...

Page 124: ...in device of manufacturer For details of the ID see the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 PCIeSW PCIeSW Displays the number of PCIeSW Status Displays the status of PCIeSW OK Warning Failed Voltage Sensor Displays the Voltage sensor type P1 8VL 1 P1 0VL 1 P2 5VL 2 P1 2VL 2 P0 8VL 2 P0 67VL 2 P3 3V 3 P1 8V_PCIEX 0 1 P1 8V_PCIEX 1 1 P1 8V 2 P0 9V_PCIEX 0 3 P0 9V_PCIEX 1 3 1 IO...

Page 125: ...oot If error is detected again at the time of reboot the error status of the IOU gets registered once again 1 Menu Operation System IOU IOU x 2 Window Operations 1 Click the Status Clear button Confirmation dialogue box is displayed 2 Click the Apply button Click the OK button to clear the error status and click the Cancel when you do not want to clear the error status of the IOU Message This sect...

Page 126: ...4 DU x Window For a user without setting privileges Status Clear button and Click the Status Clear button to clear the status Message will not be displayed When System Progress of the partition is EFI Boot and OS Running various information on RAID Card Physical Drives Logical Drives and the Action Progress table is displayed 1 1 After System Progress is changed into the state of EFI Boot and OS R...

Page 127: ... the RAID slot On Standby Slot Status Displays the status of the RAID Slot OK Not present Failed Degraded Link Width Displays the Link Width of the DU RAID slot format x1 x2 x4 x8 Seg Bus Dev Displays Segment Bus Device of the DU RAID Device RAID Card Slot The slot number equipped with the RA identification card is displayed BBU Status The state of RAID BBU is displayed Online On Battery Charging ...

Page 128: ...aid Level The RAID level of a logical drive is displayed Physical Drives assignment The slot number of a physical drive that composes a logical drive is displayed Missing drives count The number of physical drives missed to compose a logical drive at the RAID level is displayed RAID Action Progress Drive Type The drive type that the RAID action is executed is displayed Physical Hardware RAID Logic...

Page 129: ...r button is clicked the error status of the disk unit will be cleared and it can be specified so that the disk unit can be used again at the time of the next reboot When an error is detected again at the time of re boot the error status of the disk unit would be recorded again 1 Menu Operation System DU DU x 2 Window Operations 1 Click the Status Clear button A confirmation dialogue box is display...

Page 130: ...perations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 129 CA92344 0539 04 1 2 16 PCI_Box Menu The PCI_Box x window displays the status of the PCI_Box connected with the PRIMEQUEST 2000 series FIGURE 1 35 PCI_Box Window 1 ...

Page 131: ...MMB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 130 CA92344 0539 04 FIGURE 1 36 PCI_Box Window 2 FIGURE 1 37 PCI_Box Window 3 ...

Page 132: ...MMB Web UI Web User Interface Operations 1 2 System Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 131 CA92344 0539 04 FIGURE 1 38 PCI_Box Window 4 ...

Page 133: ...n Redundancy Displays the redundancy status of the fan Redundant Non redundant Sufficient Resources Part Number Displays the part number of the PCI_Box PEXU Part Number Displays the part number of the PEXU Serial Number Displays the serial number of the PEXU Location LED Displays the status of the Location LED He following are the various display statuses On Turn On Off Turn Off On Off of the Loca...

Page 134: ...cted correct connection Connect to IOU Displays the connection destination IOU When not connected the display is grayed out PCIC Displays the PCI Slot of the connection destination IOU When not connected the display is grayed out PCI Express Slots PCIC Displays the PCI Express slot number Power Status Displays the power status of the GPCI Express slot On Standby Slot Status Displays the status of ...

Page 135: ... places Critical Low High Lower and upper limits of the critical level voltage Displays when the threshold is not set Displays the power voltage in the last two decimal places TABLE 1 50 MMB x Window button Buttons Description On The Location LED lights up when the On button is clicked Off The Location LED light out when the Off button is clicked Status Clear The error status of PCI_Box is cleared...

Page 136: ...ar the status Message is not be displayed for a user without the setting privilege TABLE 1 51 Display items of OPL Window Items Description Status Displays the status of the OPL OK Not present Warning Degraded Failed Power Status Displays the Power status of the OPL On Standby Part Number Displays the part number of the OPL Location LED Displays the status of the Location LED Following are the var...

Page 137: ... displayed on this window Message Number Message I_00029 Status Clear completed E_00123 Failed to clear the status For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 1 Menu Operation System OPL 2 Window Operations 1 Click the Status Clear button Confirmation dialogue box is displayed 2 Click the OK button to clear the error message and cli...

Page 138: ... 0539 04 1 2 18 MMB Menu In MMB menu each MMB Unit has menu MMB 0 MMB 1 Since the window and the operation method are the same in all menus units of only one unit is described here MMB x Window In MMB x Window information related to MMB can be displayed and the Location LEDs can be set FIGURE 1 40 MMB x Window ...

Page 139: ...e controlled by clicking On Off buttons Reset MMB Resets the MMB if this check box is checked When this check box is checked Switch Over to MMB mentioned below cannot be set Switch Over to MMB Switches the Active Standby of the MMB if this check box is checked When this check box is checked Reset MMB mentioned above cannot be set Remarks This check box is displayed only when two MMBs are mounted E...

Page 140: ...n MMB status Message This section describes the messages to be displayed on this window Message Number Message I_00013 Setting completed I_00052 MMB switch processing has started I_00095 The standby MMB is rebooting now Please wait several minutes E_00100 Failed to set the LED E_00125 Failed to switch over to another MMB E_00125 Failed to change Enable Disable status of the MMB E_00125 Failed to r...

Page 141: ...RIMEQUEST 2000 series When Disk Enclosure is connected with IOU or PCI BOX it is displayed in the menu Attention The error of the Disk Enclosure screen is not reflected on the System Status screen If any Logical drive is not being mounted by the RAID controller with whom Disk Enclosure was connected this screen might not be displayed Please construct one or more Logical drive and refer to the scre...

Page 142: ...closure x Window 2 When System Progress of the partition is EFI Boot and OS Running various information on RAID Card Physical Drives Logical Drives and the Action Progress table is displayed 1 1 After System Progress is changed into the state of EFI Boot and OS Running until information is correctly displayed it takes one minute or less ...

Page 143: ...emperature sensor Warning Low High Critical Low High RAID Card BBU Status The state of RAID BBU is displayed Online On Battery Charging Discharging Battery Low Relearn Required Failed Not present Vendor ID Vendor ID of RAID Card is displayed Remarks ID uniquely allocated in manufacturer of card For details of the ID see the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 Device ID Device...

Page 144: ...rive at the RAID level is displayed RAID Action Progress Drive Type The drive type that the RAID action is executed is displayed Physical Hardware RAID Logical Software RAID Slot Sensor Slot from which the RAID action is executed is shown when Drive Type is Physical and Sensor from which the RAID action is executed is shown when Drive Type is Logical Action The RAID action under execution is displ...

Page 145: ...for PRIMEQUEST 2400E2 2800E2 2400E 2800E 144 CA92344 0539 04 Items Description Status Displays the status of the PSU OK Warning Failed Not Present Fans FAN The number of the Fan is displayed Status Displays the status of the Fan OK Warning Failed Not Present ...

Page 146: ...Physical Partition that satisfies the above mentioned 1 and 2 The partition of Extended Partitioning describes Extended Partition after this If with the PRIMEQUEST 2400E2 2800E2 2400E 2800E model the Extended Partitioning mode of the Physical Partition is set to Enable the background color becomes gray and the operation is supressed On the contrary when the Extended Partitioning mode of the Physic...

Page 147: ...b User Interface Operations 1 3 Partition Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 146 CA92344 0539 04 FIGURE 1 43 Power Control Window FIGURE 1 44 Power Control Window When Extended Partitioning Mode is enable ...

Page 148: ...9 04 In case of Partition Operator privilege In case of management target Partition 0 Operations can be performed only for a partition which is targeted for management When it is not targeted for management Pull down Menu and the setting items are displayed as gray out FIGURE 1 45 Power Control Window Grayout Display ...

Page 149: ...own menu of Power Control Then click the Apply button Dialog box for confirmation appears 2 Click the OK button to execute the process Click the Cancel button to cancel the process When Partition Power is On or when Power is Off and when the specified control is failed Warning dialog box appears When the CPU mounted on the SB of partition is not matched at the time of specifying the Power On of pa...

Page 150: ... the beginning of reset till the completion of the operating system boot EFI The UEFI menu screen is displayed Boot Operating system is being booted Operating system Running Operating system running state Operating system Shutdown Operating system shutting down Panic Panic Only in RHEL Power Off In Progress Partition power off is in process Fatal Stopped Dumping The dumping is being output Halt Ha...

Page 151: ...en power off is done without proper operation of the shutdown instruction for the operating system by Power Off on the partition In case enforced power off has been specified the specified time 1 9 minutes can be set The partition is forcibly powered off when the specified time has lapsed The default setting of check box is Off Boot Selector Specifies the boot device for which the Boot Manager set...

Page 152: ... not supported by the ACPI the power is turned off without shutting down the operating system Moreover when the application which is operating in the operating system is not supported even if the operating system is supported by the ACPI the power cannot be turned off Since this is according to the operating system and application specifications for details see the Operating System and Application...

Page 153: ...ion is under maintenance I_00222 Unable to aa the Partition aa because this Partition is under maintenance E_00422 Unable to power on the partition aa due to CPU composition abnormal E_00154 Unable to power on due to mismatch between supply voltage and input voltage E_00482 Unable to power on the partition aa due to DIMM composition abnormal E_00491 Unable to power on the partition aa due to DIMM ...

Page 154: ...he set time However the following interval times may be changed under the various conditions like setting and the configuration Interval time until shutdown instructions reaches OS from MMB Interval time until MMB notifies SEL begin shutdown after OS begins shutdown Even if the Power on Delay is 0 seconds it takes about 30 seconds 70 seconds from starting the power on up to the reset 1 3 2 1 Sched...

Page 155: ... Power On in Power On Delay Schedule Power Off is disregarded Moreover when OS does not accept the Shutdown demand Power Off is not done TABLE 1 58 Display Items and Setting Items of Schedule Control Window Items Description Displays the number that identifies the partition 0 3 However only the partition to which SB IOU is registered is displayed Partition Name Displays the partition name Schedule...

Page 156: ...ule list Window FIGURE 1 49 Schedule List Window Schedule will appear in the order of the partition number Partition will appear in chronological order of the start date of the period If the partition and the start date are the same the schedule appears in the sequence in which it is listed Remarks If the Type is Weekly the start date is considered to be Oneday Only the partition to be managed can...

Page 157: ...dule according to the type and the pattern of the schedule Daily Starting month and date and ending month and date Weekly Starting month and ending month Monthly Starting month and ending month Default setting is as follows Daily From Jan 1 To Jan 1 Note It is executed only on January 1 Weekly From Jan To Jan Note It is executed only in January Monthly From Jan To Jan Note It is executed only in J...

Page 158: ... with Radio button 2 Click Edit button Add Edit Schedule window appears 3 Changes an existing schedule in Add Edit Schedule window If the schedule is to be deleted 1 Select the schedule with Radio button 2 Click Remove button The confirmation dialog box appears 3 Click OK button Deletes the schedule Message This section describes the messages to be displayed on this window Message Number Message I...

Page 159: ...dit Schedule window In Add Schedule window the schedule of Power On Off for each partition can be added newly In Edit Schedule window an existing schedule can be changed The window items of Add Schedule window and Edit Schedule window are common In this section an explanation is given by using the Add Schedule window FIGURE 1 50 Schedule List Window ...

Page 160: ...thly Weekly Daily By default it is not selected Pattern Specify the schedule pattern corresponding to the types of the schedule Weekly Day in a week Sun Sat Monthly Period in a month Special Specified month Default settings are as follows Day in a week Not selected Period From 1 To 1 Specified date Jan 1 Term Specify the period of the schedule according to the type and pattern of the schedule Dail...

Page 161: ...partition Cancel If the Cancel button is clicked returns to the original sate without applying the schedule information specified in each item Message This section describes the messages to be displayed on this window Message Number Message I_00013 Setting completed W_00414 Invalid Date Format W_00415 The duplicate On Off Time is found W_00416 Both On Off Time are disabled For details on the messa...

Page 162: ...w The IP address settings for accessing Console Redirection Setup of IPv4 subnet mask video redirection and enable disable settings of virtual media can be done in the IPv4 Console Redirection Setup window In the Extended Partitioning mode the background color of Physical Partition having Enable setting is displayed in scarlet and the operations are restrained The background color of the Extended ...

Page 163: ... used Default is Disable Virtual Media is not possible to use it even if set to Enable that VGA USB2 is not allocated for Extended Partition TABLE 1 65 IPv4 Console redirection Setup Window Buttons Buttons Description Apply When Apply button is clicked video redirection virtual media settings of the specified Partition are applied Cancel When Cancel button is clicked video redirection virtual medi...

Page 164: ... can be done in the IPv6 Console Redirection Setup window In the Extended Partitioning mode the background color of the Physical Partition which works in Enable settings is displayed in gray and the operations are restrained The background color of Extended Partition to which VGA USB2 rKVMS is not allocated is displayed in gray and the operations are restrained In case of automatic settings when A...

Page 165: ...ically acquired the Auto button is clicked IP address and prefix length are automatically acquired and overwritten TABLE 1 67 IPv6 Console redirection Setup Window Buttons Buttons Description Auto When you Click Auto button IP address and prefix length is automatically displayed Apply When you click the Apply button video direction of the specified partition virtual media setting is applied Cancel...

Page 166: ... Menu The SB and IOU which configure the partition can be set on Partition Configuration window In case of PRIMEQUEST 2400E2 2400E model only 0 and 1 are displayed for partition Attention of operation Do not start two or more Web screen when you change Extended Partitioning and change on a single Web screen FIGURE 1 53 Partition Configuration Window ...

Page 167: ...d select the button corresponding to set process from Add Unit Remove Unit and Home Unit of Add Unit Remove Unit button means SB IOU or Extended Partitioning If SB IOU link is clicked SB x window IOU x window are displayed respectively If the maintenance mode Hot Partition Maintenance Warm System Maintenance or Cold system Maintenance is set only the user Maintenance person Administrator privilege...

Page 168: ... Partition Name Sets the name in the partition Add Unit Displays the Add Unit window for incorporating the unit Remove unit Displays the Remove Unit window for deleting the unit Home Displays the Partition Home window for setting the Home of Partition Cancel Returns to original status without setting the information Message This section describes the messages to be displayed on this window Message...

Page 169: ...n Set Partition Name button is clicked the name for each partition is set 1 3 4 2 Add SB IOU to Partition Window When the partition is selected by using radio button of Partition Configuration window and when Add Unit button is clicked Add SB IOU to Partition window appears FIGURE 1 55 Add SB IOU to Partition Window FIGURE 1 56 Add SB IOU Extended Partitioning to Partition Window When Extended Par...

Page 170: ...e or Cold system Maintenance is set only the user Maintenance person Administrator privilege who sets the maintenance mode can operate this mode In case of the partition other than the maintenance target a message is displayed and operation is not possible The addition of Memory Scale up Board to Partition that Dynamic Reconfiguration Mode is effective cannot be set by warning Dialog box being dis...

Page 171: ...ition E_00112 Unable to add the specified SB aa to the partition due to CPU mismatch between SBs E_00424 Unable to add the specified SB to the partition due to CPU composition abnormal E_00425 Unable to add the specified SB to the partition due to DIMM composition abnormal E_00490 Unable to add the specified SB to the partition due to DIMM does not satisfy requirements of Mode W_00505 Unable to se...

Page 172: ...0E2 2400E 2800E 171 CA92344 0539 04 1 3 4 3 Remove SB IOU from Partition Window Select the partition by using radio button of Partition Configuration window and when Remove Unit button is clicked Remove SB IOU from Partition window appears FIGURE 1 57 Remove SB IOU from Partition Window ...

Page 173: ...ve SB IOU to partition Window Items Description SB IOU Extended Partitioning Displays SB which belongs to partition Status Displays the status of SB IOU Extended Partitioning Note SB Number of CPUs Displays the number of CPUs mounted on the SB This item is not displayed for Memory Scale up Board Memory Displays the amount of memory mounted on the SB IOU Number of PCI Express slots Displays the num...

Page 174: ...p Board is excluded which is set as Home SB is not mounted the background color is displayed in gray You can switch from the selected radio button on a grayed row to a radio button on a row that is not grayed However if the selection on the row displayed in gray is removed once it is not possible to select the original radio button again When the Home SB is not set the SB Memory Scale up Board is ...

Page 175: ...ssages to be displayed on this window Message Number Message E_00022 The partition doesn t have a node W_00423 The partition home cannot be changed while the partition is running Please try to change the partition home after the partition is shutdown For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 ...

Page 176: ...e of Physical Partition is set to Enable in Partition Partition x Mode The configuration of Extended Partition can be changed Attention of operation Do not do the configuration change setting in Power On of Partition Do not start two or more Web screens when you change Extended Partitioning and change on a single Web screen 1 3 5 1 SB window The resource allocation setting window of SB related to ...

Page 177: ... the GB unit Check the SKT Binding check box for Extended Partitions Then click the Apply button CPU and Memory are assigned from some two CPU Sockets and DIMM under those CPUs for the checked Partition Select the radio button to allocate USB1 VGA USB2 Remote KVMS and PCI Slot Then click the Apply button Source for specified Partition allocates To recommend the user operation that does not allocat...

Page 178: ...nel Mode DIMM Error Isolation Allocation granularity of Memory remarks Performance Mode Independent Mode DIMM 1 piece As much as two capacity of DIMM in the maximum capacity in Partition The total capacity that can be allocated is a value in which 2GB is pulled from actual capacity Normal Mode Default Lockstep Mode DIMM 2 pieces Partial Mirror Mode The total capacity that can be allocated with Hom...

Page 179: ...GB by DIMM group unit Memory GB Displays and sets the GB of memory that was allocated to the Extended Partition Memory EXCL Sets DIMM Exclusive Allocation mode At the time of failure in order to limit the extent of impact to one Partition the Option is selected which exclusively allocates the DIMM for Extended Partitioning When this Option is selected and when the value specified in the Memory GB ...

Page 180: ...utton Return to Extended Partition Configuration of SB Resources Message This section describes the messages to be displayed on this window Message Number Message E_000544 Unable to change Extended Partitioning Configuration to Partition aa because this partition is under maintenance W_00545 Unable to change Extended Partitioning Configuration to Partition aa because this partition is power on W_0...

Page 181: ... Disk Unit is selected by using the radio button and when Apply button is clicked the resource is allocated to the specified Partition Only the CPU Cores and the Memory GB are displayed When Cancel button is clicked process is cancelled When PCNC to connect the PCI_Box with PCI Slot 2 and 3 is mounted background color is displayed in gray and the operation is suppressed When the Disk Unit is not m...

Page 182: ...d sets the Extended Partition to which GbE of IOU x belongs IOU x PCI Slot y Displays and sets the Extended Partition to which PCI slot y of IOU x belongs IOU x Disk Unit Displays and sets which Extended Partition to which Disk Unit of IOU x belongs The following windows are displayed when the Extended Partitioning number is not allocated in the Partition Partition Configuration Window FIGURE 1 64...

Page 183: ...ce CA92344 0540 1 3 5 3 PCI_Box window When selection is possible resource allocation set screen of PCI_Box is displayed for the Extended Partition when Partition x Extended Partition Configuration PCI_Box page is selected FIGURE 1 65 Extended Partition Configuration of PCI_Box Resources windows Allocation of PCI Slot is selected by radio button If Apply button is clicked the resources for the spe...

Page 184: ...he Memory of GB that was allocated to Extended Partition PCI_Box x PCI Slot y Displays the Extended Partition to which PCI Slot y of PCI_Box x belongs and sets it The following window is displayed when Extended Partitioning number is not allocated in the Partition Partition Configuration window FIGURE 1 66 Extended Partition Configuration of PCI_Box Resources no Extended Partitioning Window 1 Menu...

Page 185: ...ge E_000544 Unable to change Extended Partitioning Configuration to Partition aa because this partition is under maintenance W_00545 Unable to change Extended Partitioning Configuration to Partition aa because this partition is power on W_00589 Unable to change Resources because this partition is powered on For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Refe...

Page 186: ...nge of Extended Socket FIGURE 1 67 Extended Socket Configuration window The Zone setting is reflected by clicking the Apply button after the setting of Zone is changed by the radiobutton Even if the power supply of Extended Partition is On this setting can be changed Sharing Zone between Extended Partition is possible only for same physical partition the division origin When Zone that tried to be ...

Page 187: ... Power Status The state of the power supply of partition is displayed On Standby Extended Socket Displays whether Extended Socket function is Enabled or Disabled Enabled Disabled Zone Zone that Extended Socket connects is selected Zone of the connection destination is up to Zone0 3 for PRIMEQUEST 2400E2 2400E model and Zone0 Zone7 for PRIMEQUEST 2800E2 2800E model One Zone of each Extended Partiti...

Page 188: ...Operation Partition Extended Socket Configuration 2 Window OperationsExtended Socket Configuration 1 Set the items for changing the settings of the Extended Socket Configuration and click the Apply button Set the connection Message This section describes the messages to be displayed on this window Message Number Message W_00598 Unable to change Extended Socket configuration because this zone is al...

Page 189: ...conditions Mounting of one CPU for an SB is possible only when the Partition is configured with one SB Mounting of two 2CPUs for an SB is mandatory when the Partition is configured with several SB The Reserved SB cannot be set when TPM function is used The Reserved SB cannot be set though Fixed I O Mode is specified in the Partition When mounting conditions are not fulfilled a message is displayed...

Page 190: ... the Partition Enable Mode is set Disable Mode is not set SB Displays the Partition to which the SB belongs The check box to register the SB as a Reserved SB in the Partition of the corresponding line is displayed in the cell which corresponds to Reserved SB or Free SB TABLE 1 79 Reserved SB Configuration Window Buttons Buttons Description Apply If Apply button is clicked it is defined as Reserved...

Page 191: ...as a Reserved SB because the DIMM does not satisfy requirements of Mode E_00421 No change E_00460 Unable to set the specified SB to the partition due to CPU composition abnormal W_00481 Unable to register the specified SB s as a Reserved SB due to the home SB is TPM enabled W_00492 Unable to register the specified SB d as a Reserved SB due to Partition is Fixed I O Mode W_00493 Unable to register ...

Page 192: ...gement Setup Window In the Power Management Setup window Power Saving can be set in the partition unit Power Saving can be set only when the Power save Control of the system is Enable When the System Power Save setting is Disable then the display of this screen is shown as gray and cannot be set FIGURE 1 70 Power Management Setup window ...

Page 193: ...the operation is controlled Power save Grace Period Sets shutdown waiting time in partition unit when the Limit threshold is exceeded Specified in the range of 0 99 minutes Shows a valid item when Power Save Control of partition is Enable and shows gray color when Disable Default is 5 minutes Action reaching Power Save Executes the operation setting in the partition unit after the Limit threshold ...

Page 194: ...t Partition Power Management E_00098 Failed to get the system configuration W_00559 Unable to set Power Save Control because PSU type is not PSU_P W_00560 Unable to set Partition Power Save Control because System Power Save Control is disabled E_00100 Failed to set Partition Power Management W_00603 Unable to set Partition Power Save Control because Extended Partitioning Mode is enabled For detail...

Page 195: ...wing settings and the displays for the partition can be done in the Partition x menu Status display ASR condition setting Video redirection display Various modes 1 3 9 1 Information Window Displays the status of the partition and various information on the partition on the information screen FIGURE 1 71 Information Window In case of a Physical Partition ...

Page 196: ...MMB Web UI Web User Interface Operations 1 3 Partition Menu for PRIMEQUEST 2400E2 2800E2 2400E 2800E 195 CA92344 0539 04 FIGURE 1 72 Information Window In case of a Extended Partition ...

Page 197: ...t displayed if SVAS is not installed Core Max Core Assigned Core Requested Core The CPU core number included in the partition Max Core number is displayed in the Physical Partition The CPU core number that is actually allotted and the CPU core number that is specified on the Extended Partition Configuration screen are displayed on the Extended Partition is displayed for the actually allotted CPU c...

Page 198: ...0E 197 CA92344 0539 04 1 Menu Operation Partition Partition x Information 2 Window Operations None 1 3 9 2 ASR Control Window The conditions for executing automatic restart of the partition on the ASR Automatic Server Restart Control can be set FIGURE 1 73 ASR Automatic Server Restart Control Window ...

Page 199: ...ata for investigation damp for the investigating the cause of stoppage of the partition which has stopped Default setting is Stop rebooting and Power Off Retry Counter Displays the number of actual possible retries Boot Watchdog Boot Watchdog Enable disable of the Boot Watchdog function of ServerView is set The start of OS is observed when setting it to Enable After OS starts Boot Watchdog is stop...

Page 200: ...Control Window Buttons Buttons Description Apply Sets the information if Number of Restart Tries Action after exceeding Restart tries are specified Cancel Does not set the information and returns to the original state 1 Menu Operation Partition Partition x ASR Control 2 Window Operations 1 Every item is set 2 Apply button is clicked Specified information is set ...

Page 201: ...ey to permit the display of pop up Console Redirection can be connected only by the click of a mouse for Firefox TABLE 1 85 Display Items of Console Redirection Window Items Description Video Redirection Displays the Video Redirection on the BMC side On the Console Redirection Setup window selection is possible only when Enabled when Disabled the check box cannot be checked In the Physical Partiti...

Page 202: ...ation due to WEB Session Max over W_00473 Unable to check the Video Redirection check box due to the Video Redirection option is disabled I_00222 Unable to aa the Partition aa because this Partition is under maintenance I_00417 Are you sure W_00541 Nothing is checked W_00550 Unable to select the option due to this Partition is not connected to VGA USB2 rKVMS W_00551 Unable to select the option due...

Page 203: ...an be set for partition in Mode window In order to reflect the set value turn Off the power of partition and then it is necessary to turn On the Power of partition once again Attention of operation Do not start two or more Web screen when you change Extended Partitioning and change on a single Web screen FIGURE 1 75 Mode Window 1 FIGURE 1 76 Mode Window 2 ...

Page 204: ...itioning mode after the Physical Partition is powered off is displayed and settings are prohibited When SB with DIMM configuration that does not satisfy requirements of Mode configures the Mode for the partition configured in a Reserved SB a confirmation dialogue box is displayed At the time of switching to the Reserved SB a warning message of Mode cancellation is displayed and to confirm whether ...

Page 205: ...on Mode setting Sets the Memory Operation Mode for partition Performance Mode Normal Mode Partial Mode Full Mode Spare Mode Enables the settings after rebooting the partition Default setting is Normal Mode Memory Mirror RAS Mode current status Displays the Memory Mirror currently enabled Mode Mirror Keep Mode Shows the maintenance of Mode Capacity Keep Mode Shows maintenance of memory capacity Mem...

Page 206: ...ent Mode Enables the settings after rebooting the partition Default setting is PCI Segment Mode Dynamic Reconfiguration current status Displays whether Dynamic Reconfiguration Function is enabled or disabled Enable Disable Dynamic Reconfiguration setting Sets whether the Dynamic Reconfiguration Function is enabled or not Enable Enables the Dynamic Reconfiguration Function Disable Disables the Dyna...

Page 207: ...led Onboard LAN can be used at AC On status Enabled WOL disabled Onboard LAN comprised in the partition can be used at Power On status Disabled Onboard LAN cannot be used every time On board LAN Mode setting Sets On board LAN Device Mode in IOU Unit Select the Mode to be set by using the radio button Enabled WOL enabled Enabled WOL disabled Disabled Default setting is Enabled WOL disabled On board...

Page 208: ...e to register the specified Partition s as Mode enable because of abnormal DIMM composition I_00501 The SB with DIMM that does not satisfy requirements of Mode is registered as a Reserved SB If you register this partition as a Mode Mode will be disabled when switching to Reserved SB Are you sure to continue E_00521 Unable to register the specified Partition s as Mode enable because of abnormal SB ...

Page 209: ...t TABLE 1 88 Display items in the User List window Items Description User Name Displays the user name The user name must consist of a total of 3 to 32 characters Full Name Used to enter the user s real name or other related information You can enter up to 32 characters Privilege Displays the privileges of the user account Status Displays the current status of this account Enabled Disabled Operable...

Page 210: ...this window Message Number Message E_00031 Same name already exists User addition failed E_00032 No more User addition E_00034 Unable to change the status to Disable because the specified user is last Administrator E_00035 The user is logining User deletion failed I_00041 User addition was completed I_00042 User information editing was completed I_00043 User deletion was completed W_00463 Select a...

Page 211: ...r button in the User List window displays the Add User window You can register new users in the Add User window It is possible to register up to 16 users or less FIGURE 1 79 Add List Window For details on the setting and display items in the Add User window see TABLE 1 90 Setting and display items in the Add User and Edit User windows ...

Page 212: ...ser window Selecting a user and clicking the Edit User button in the User List window displays the Edit User window You can change management information on user accounts in the Edit User window Changes in the administrative information of User other than User Name can be done FIGURE 1 80 Edit List Window ...

Page 213: ... to reenter a password for confirmation Privilege Sets the privileges of the user account Partition Operator is not displayed in PRIMEQUEST 2800B2 2800B Status Sets the current status of this account Enabled Disabled Full Name Used to enter the user s real name or other related information You can enter a total of up to 32 characters Operable Partition for Partition Operator This item is not displ...

Page 214: ...ll Name W_00407 Input characters are too long W_00408 Partitions are not selected Please select at least one partition For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 1 4 1 3 Remove User button To delete a user account select a user in the User List window and then click the Remove User button A deletion confirmation dialog box appears ...

Page 215: ...ndow Remarks The entered password must consist of at least eight characters The message to the effect that should be input by eight characters or more is displayed for eight characters or less The password that can be analogized cannot be set again TABLE 1 92 Buttons in the Change Password window Buttons Description Apply Registers the changed password Cancel Restores the original information and ...

Page 216: ... while setting E_00018 Information acquisition failed E_00036 Changing Password failed I_00037 Changing Password completed W_00404 Password differs from the re password W_00402 Password is too short W_00403 Invalid character is included in Password I_00417 Are you sure W_00462 The specified password is invalid For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message R...

Page 217: ...port was used for the login this field displays hyphen From Displays the host name or the IP address IPv4 or IPv6 address of a remote host if the user logged in remotely If the host name can be identified from the DNS set on the MMB at the login time this field displays the host name Otherwise it displays the IP address If the serial port of the MMB was used for the login the field displays hyphen...

Page 218: ...n Menu 217 CA92344 0539 04 1 5 Network Configuration Menu The Network Configuration menu is available only to users who have Administrator privileges 1 5 1 Date Time window You can set the date and time of the MMB in the Date Time window FIGURE 1 83 Date Time window ...

Page 219: ...is synchronized with immediately after the Enable setting at the time of the server side regardless of the setting of NTP Time Correction Mode The default is Disable NTP Time Correction Mode Sets an NTP time correction mode This item is valid only if NTP is Enable If it is set to Disable the item is grayed out Step If the time difference with the NTP server is less than 128 milliseconds the MMB us...

Page 220: ...1 95 Buttons in the Date Time window Buttons Description Apply Sets the specified information Cancel Restores the original information and does not set the specified information such as the date and time zone 1 Menu Operation Network Configuration Date Time 2 Window Operations 1 Specify information such as the date and time zone Then click the Apply button This sets the information such as the dat...

Page 221: ...inutes the NTP executes Slew adjustment which corrects the time at a rate of up to 0 0005 per second without reversal 2 outside a range of 600 to 600 seconds 10 minutes and within a range of 1000 to 1000 seconds 16 minutes and 40 seconds the NTP executes Step adjustment In this case the clock may be reversed 3 outside a range of 1000 to 1000 seconds 16 minutes and 40 seconds the NTP function stops...

Page 222: ...rface window The Network Interface menu has the following windows IPv4 Interface window IPv6 Interface window 1 5 2 1 IPv4 Interface window You can set the IPv4 IP address for MMB access and other related items in the IPv4 Interface window FIGURE 1 84 IPv4 Interface window PRIMEQUEST 2400E2 2800E2 2400E 2800E 1 ...

Page 223: ...MMB Web UI Web User Interface Operations 1 5 Network Configuration Menu 222 CA92344 0539 04 FIGURE 1 85 IPv4 Interface window PRIMEQUEST 2400E2 2800E2 2400E 2800E 2 ...

Page 224: ...IP Address Sets the IP address Subnet Mask Sets the subnet mask Gateway address Sets the gateway IP address MMB 0 IP Address Sets the physical IP address assigned to the MMB 0 interface This item is available only if the system has MMB 0 You cannot access the Web UI from this interface Unless MMB 0 is mounted the window does not display the MMB 0 IP Address table Interface Enable Disable Hostname ...

Page 225: ... PRIMEQUEST 2400E2 2800E2 2800B2 The default is Enable In case of PRIMEQUEST 2400E 2800E 2800B The default is Disable IP Address Sets the IP address In case of PRIMEQUEST 2400E2 2800E2 2800B2 The default is 192 168 1 1 Subnet Mask Sets the subnet mask In case of PRIMEQUEST 2400E2 2800E2 2800B2 The default is 255 255 255 0 Gateway address Sets the gateway IP address SMTP address Sets the SMTP IP ad...

Page 226: ...MMB Web UI Web User Interface Operations 1 5 Network Configuration Menu 225 CA92344 0539 04 FIGURE 1 87 IPv4 Interface window PRIMEQUEST 2800B2 2800B 2 ...

Page 227: ...ess Sets the gateway IP address DNS optional DNS Sets whether to use the DNS server To use the DNS select Enable The default is Disable DNS Server 1 Sets the IP address of the Primary DNS server DNS Server 2 Sets the IP address of the Secondary DNS server DNS Server 3 Sets the IP address of the Third DNS server Management LAN Dualization Duplicates the management LAN The default is Disable Mainten...

Page 228: ... information Then click the Apply button This sets the specified information such as the IP address Message The following table lists the messages displayed in this window Message Number Message W_00433 The duplicate IP address was found W_00538 Invalid hostname was found W_00432 Invalid IP Address specified I_00221 Unable to change Network Interface because the system is under maintenance W_00595...

Page 229: ... Network Configuration Menu 228 CA92344 0539 04 1 5 2 2 IPv6 Interface window You can set the IP address for MMB access and other related items in the IPv6 Interface window FIGURE 1 88 IPv6 Interface window PRIMEQUEST 2400E2 2800E2 2400E 2800E 1 ...

Page 230: ...MMB Web UI Web User Interface Operations 1 5 Network Configuration Menu 229 CA92344 0539 04 FIGURE 1 89 IPv6 Interface window PRIMEQUEST 2400E2 2800E2 2400E 2800E 2 ...

Page 231: ...ix Length Sets the prefix length Gateway address Sets the gateway IP address MMB 0 IP Address Sets the physical IP address assigned to the MMB 0 interface This item is available only if the system has MMB 0 You cannot access the Web UI from this interface Unless MMB 0 is mounted the window does not display the MMB 0 IP Address table Interface Sets whether to enable or disable the MMB 1 physical IP...

Page 232: ... Sets the IP address of the Third DNS server Management LAN Duplicates the management LAN Dualization Duplicates the management LAN The default is Disable Maintenance IP Address Interface Sets whether to enable or disable the CE REMCS LAN interface The default is Disable IP Address Sets the IP address Prefix Length Sets the prefix length Gateway address Sets the gateway IP address SMTP address Set...

Page 233: ...MMB Web UI Web User Interface Operations 1 5 Network Configuration Menu 232 CA92344 0539 04 FIGURE 1 91 IPv6 Interface window PRIMEQUEST 2800B2 2800B 2 ...

Page 234: ...tically acquires data with a click of the Auto button The global address prefix length and gateway IP address are automatically acquired to overwrite existing data IP Address Sets the IP address Prefix Length Sets the prefix length Gateway address Sets the gateway IP address DNS optional DNS Sets whether to use the DNS server To use the DNS select Enable The default is Disable DNS Server 1 Sets th...

Page 235: ...face information Then click the Apply button This sets the specified information such as the IP address Message The following table lists the messages displayed in this window Message Number Message W_00433 The duplicate IP address was found W_00538 Invalid hostname was found W_00432 Invalid IP Address specified W_00532 Invalid Prefix Length E_00533 Automatic Acquisition failure I_00221 Unable to ...

Page 236: ...t LAN Port Configuration window You can make the Speed Duplex setting for each port on the MMB in the Management LAN Port Configuration window FIGURE 1 92 Management LAN Port Configuration window PRIMEQUEST 2400E2 2800E2 2400E 2800E FIGURE 1 93 Management LAN Port Configuration window PRIMEQUEST 2800B2 2800B ...

Page 237: ... used with 1G Full Auto is specified Maintenance port Sets Speed Duplex for the MMB 0 Maintenance port Auto 100M Full 100M Half 10M Full 10M Half The default is Auto Remarks The window displays this item only if MMB 0 is mounted REMCS port Sets Speed Duplex for the MMB 0 REMCS port Auto 100M Full 100M Half 10M Full 10M Half The default is Auto Remarks The window displays this item only if MMB 0 is...

Page 238: ...ll 100M Half 10M Full 10M Half The default is Auto Remarks The window displays this item only if MMB 1 is mounted TABLE 1 103 Setting and display items in the Management LAN Port Configuration window in case of PRIMEQUEST 2800B2 2800B Items Description Speed Duplex for MMB User port Sets Speed Duplex for the MMB User port Auto 100M Full 100M Half 10M Full 10M Half The default is Auto Remarks When ...

Page 239: ...ration window Buttons Description Apply Sets the entered information Cancel Restores the original information and does not set the specified information for the Speed Duplex setting 1 Menu Operation Network Configuration Management LAN Port Configuration 2 Window Operations 1 Specify Speed Duplex Then click the Apply button This sets Speed Duplex ...

Page 240: ...Interface Operations 1 5 Network Configuration Menu 239 CA92344 0539 04 1 5 4 Network Protocols window You can configure the network protocols of the MMB in the Network Protocols window FIGURE 1 94 Network Protocols window ...

Page 241: ...se of PRIMEQUEST 2400E 2800E 2800B The default is Disable Telnet Port Sets the port number used for Telnet The default is 23 Timeout Sets the length of time before a time out due to no input causes the termination of a Telnet connection You can specify 0 or a value in a range of 60 to 9999 0 means there is no time out The default is 600 seconds SSH SSH Sets Enable or Disable for SSH The default is...

Page 242: ...rotocols 2 Window Operations 1 Specify the port numbers time out time or other items to set as protocol information Then click the Apply button This sets the specified information such as the port numbers and time out time Message The following table lists the messages displayed in this window Message Number Message I_00013 Setting completed E_00044 The Port number overlaps W_00435 Invalid Port nu...

Page 243: ...splay dynamic content With Enable specified you can set the time interval of the automatic refresh in units of seconds The specifiable time interval for Refresh Rate is in a range of 5 to 999 seconds When the setting of Refresh Rate is Disable it is not refreshed automatically The default is Disable Remarks When Dialog Box is displayed Refresh is not automatically done even if Refresh Rate is set ...

Page 244: ...elect Enable enter the time interval 2 Click the Apply button This sets the information for automatic refresh Message The following table lists the messages displayed in this window Message Number Message I_00013 Setting completed W_00441 Range over error For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 ...

Page 245: ...ation window The SNMP Configuration menu has the following windows SNMP Community window SNMP Trap window SNMP v3 Configuration window 1 5 6 1 SNMP Community window You can configure SNMP in the SNMP Community window You can specify up to 16 items for Community User from the MMB FIGURE 1 96 SNMP Community window ...

Page 246: ...ion Sets the SNMP version 1 2 3 Access Sets whether to permit only reading or both reading and writing Read Only Read Write Auth Sets the security level You can specify this only if 3 is selected for SNMP Version noauth Do not use the authentication function auth Use the authentication function priv Use the authentication function and privacy function data encryption With 1 or 2 selected for SNMP ...

Page 247: ...sage Number Message I_00013 Setting completed W_00595 It is IP address that duplicates with MMB IP address For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 1 5 6 2 SNMP Trap window You can set SNMP trap destinations in the SNMP Trap window You can set up to 16 trap destinations FIGURE 1 97 SNMP Trap window ...

Page 248: ...This item takes effect only if 3 is selected for SNMP Version and auth or priv is selected for Auth Priv passphrase Sets a passphrase for encryption This item takes effect only if 3 is selected for SNMP Version and priv is selected for Auth TABLE 1 112 Buttons in the SNMP Trap window Buttons Description Apply Sets the specified information Cancel Restores the original information and does not set ...

Page 249: ...rs take effect only after the SNMP Service is stopped and restarted For this reason clicking the Apply button temporarily stops SNMP Service and then automatically restarts it FIGURE 1 98 SNMP v3 Configuration window TABLE 1 113 Setting and display items in the SNMP v3 Configuration window Items Description Engine ID Sets the Engine ID You can use alphanumeric characters spaces and the following c...

Page 250: ...he selected user 1 Check the check box of the user Then enter any necessary information Finally click the Apply button This enables the information on the selected user Meanwhile the SNMP Service stops once and then restarts Disabling the selected user 1 Check the check box of the user to set to disable Leave the User Name blank Then click the Apply button This disables the selected user Message T...

Page 251: ...eate Selfsigned Certificate window 1 5 7 1 Create CSR window You can create a secret key and the corresponding CSR certificate signing request in the Create CSR window The following input items follow the guidelines issued by each certificate authority independently Therefore enter these items in accordance with the guidelines of the certificate authority selected as the destination FIGURE 1 99 Cr...

Page 252: ...o 56 specifiable characters Common Name Sets the FQDN of the server of the owner specified in the created CSR The FQDN must consist of up to 56 specifiable characters e g www mycompany com The browser uses this information to identify the website To establish secure connections some browsers reject an electronic certificate if the Common Name in it does not match the server name Common Name cannot...

Page 253: ...ists the messages displayed in this window Message Number Message W_00426 Invalid values specified I_00444 Previous private key will be overwritten with new private key Are you sure I_00465 A new Key and a CSR are generated successfully To use the new Key click OK button E_00012 One or more errors occurred while setting E_00018 Information acquisition failed For details on the messages displayed o...

Page 254: ...ort a secret key or CSR certificate signing request stored on the MMB from the Export Key CSR window Remarks For security reasons be careful with the storage of a secret key Also you need this secret key to use the electronic certificate for the key We recommend you create a backup of the secret key FIGURE 1 101 Export Key CSR window ...

Page 255: ...2 Specify the save path This saves the secret key to the specified path Exporting the CSR 1 Click the Export CSR button A dialog box appears 2 Specify the save path This saves the CSR to the specified path Message The following table lists the messages displayed in this window Message Number Message I_00013 Setting completed I_00445 Private Key is exported Are you sure I_00446 CSR is exported Are ...

Page 256: ...port Imports the electronic certificate Cancel Cancels importing 1 Menu Operation Network Configuration SSL Import certificate 2 Window Operations 1 Click the Browse button to select an imported file Then click the Import button This imports the electronic certificate Message The following table lists the messages displayed in this window Message Number Message I_00013 Setting completed I_00046 Im...

Page 257: ...g a selfsigned certificate confirm that HTTPS is set to Disable in the Network Protocols window If it is set to Enable change it to Disable Then proceed to the operations in this window FIGURE 1 103 Create Selfsigned Certificate window TABLE 1 119 Display items in the Create Selfsigned Certificate window Items Description Term Sets the valid term of a selfsigned certificate as a number of days For...

Page 258: ...secret key and the ISO country code of the owner Then click the Create Selfsigned Certificate button A confirmation dialog box appears 3 Click the OK button in the dialog box This creates the selfsigned certificate It takes a few minutes to create When creation is completed the window is updated This updated window displays the message SSL certificate status A signed certificate is installed Messa...

Page 259: ...w Buttons Description Create SSH Server Key Creates a private key for the SSH server 1 Menu Operation Network Configuration SSH Create SSH Server Key 2 Window Operations 1 Before you create a private key confirm that SSH is set to Disable in the Network Protocols window 2 Click the Create SSH Server Key button This creates the private key It can take a few minutes to create When creation is comple...

Page 260: ...ing table lists the messages displayed in this window Message Number Message I_00013 Setting completed I_00453 SSH Server Key is generated successfully To install this new SSH Server Key click OK button For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 ...

Page 261: ...rs can be registered The default settings for all users are Disabled status and No Access Also a default user name from User1 to User24 is assigned to each user For remote management of the MMB via RMCP you need to specify User Name Password and Privilege to place the users of the managed MMB in the Enabled status Remote access authentication uses the user name and password of a user in the Enable...

Page 262: ... Management window Buttons Description Edit Displays the Edit User window Cancel Restores the original information and does not set the management information for the selected user 1 Menu Operation Network Configuration Remote Server Management 2 Window Operations 1 Click the radio button of the user you want to specify Then click the Edit button you want to specify Then click the Edit button 2 Sp...

Page 263: ... name can contain the following characters 0 to 9 a to z and A to Z alphanumeric characters only Password Specifies a password The name can have a total of 8 to 16 characters The password can contain the following characters 0 to 9 a to z and A to Z alphanumeric characters only Confirm Password Used to reenter a password for confirmation Privilege Specifies the privileges of the user account Admin...

Page 264: ...Specify the user management information such as a user name and password Then click the Apply button This sets the user management information Message The following table lists the messages displayed in this window Message Number Message I_00013 Setting completed W_00401 Username is too short W_00402 Password is too short W_00454 aa is duplicated W_00406 Invalid character is included in User Name ...

Page 265: ...control filters with the same configuration These filters do not affect operation FIGURE 1 107 Access Control window TABLE 1 126 Setting and display items in the Access Control window Items Description Select Used to select the filter for which you want to change the setting Protocol Displays the protocol for IP filtering HTTP HTTPS Telnet SSH SNMP IP Address Displays the IP address permitted to c...

Page 266: ...e new filter Editing a filter 1 Click the radio button of a filter in the Select column so that you can edit the filter Then click the Edit Filter button The Edit Filter window appears 2 Specify the save path Edit the filter in the Edit Filter window Then click the Apply button Deleting a filter 1 Click the radio button of a filter in the Select column so that you can delete the filter Then click ...

Page 267: ...ilter button or Edit Filter button in the Access Control window to display the Add Filter window or Edit Filter window respectively Although the Add Filter window and Edit Filter window have different window titles their setting items are the same This section describes these items in the Add Filter window FIGURE 1 108 Add Filter window ...

Page 268: ... 255 0 because the IP address is used with a 24 bit subnet mask The above setting will enable access not only from the IP address 192 168 60 60 but also from IP addresses within the subnet 192 168 60 0 24 Subnet Mask Prefix Length For IPv4 the subnet mask of the IP address that has permission to connect is displayed For IPv6 the prefix length is displayed TABLE 1 129 Buttons in the Add Filter wind...

Page 269: ... The default is unchecked Upon receiving an alarm e mail the mail server sets the set From address for Return Path in the e mail header Also if a mailing list is used the Return Path setting is the administrator s address on the mailing list instead of the set From address However the Return Path setting depends on the mail server settings Therefore Return Path may not be set To Sets the e mail ad...

Page 270: ...ion window for setting conditions for the events for which alarm e mail is sent Test E Mail Sends a test alarm e mail to the specified destination 1 Menu Operation Network Configuration Alarm E Mail 2 Window Operations 1 Specify information such as the sender s e mail address and whether to enable or disable Alarm E Mail 2 To set a filter for an event for which alarm e mail is sent click the Filte...

Page 271: ... window displays the Alarm E Mail Filtering Condition window The display item is different depending on the model You can set the filtering conditions for the events for which alarm e mail is sent in the Alarm E Mail Filtering Condition window Each item is evaluated with the AND condition FIGURE 1 110 Alarm E Mail Filtering Condition window PRIMEQUEST 2400E2 2800E2 2400E 2800E ...

Page 272: ...MMB Web UI Web User Interface Operations 1 5 Network Configuration Menu 271 CA92344 0539 04 FIGURE 1 111 Alarm E Mail Filtering Condition window PRIMQUEST 2800B ...

Page 273: ...EST 2400E2 2400E model the Unit display is as follows 1 SB SB 0 SB 1 In case of PRIMEQUEST 2800B2 2800B model the Unit display is as follows MMB MMB In case of PRIMEQUEST 2800B2 2800B model PCI_Box is not displayed Source Used to select the sources to be displayed The selected radio button is either All or Specified All Filtering by Source is not applied Specified Filtering by source can be set Ch...

Page 274: ... unify a firmware update in the Unified Firmware Update window The firmware complete set is up loaded to MMB and the firmware in the new publication is maintained Confirm the version of each firmware Update the firmware only if those versions are not the same The online firmware update does not update the same version number situation Note If the MMB or SB has failed perform maintenance on it befo...

Page 275: ...id firmware file I_00474 Unable to execute SEL download due to resource lock Please retry after waiting a while I_00474 Unable to execute Firmware Update due to resource lock Please retry after waiting a while W_00476 Unable to execute the online update Please try the update after the system power off W_00477 Select the file of update W_00478 Unable to execute the update Standby MMB is fault or di...

Page 276: ...Backup BIOS Configuration window for PRIMEQUEST 2400E2 2800E2 2400E 2800E Restore BIOS Configuration window for PRIMEQUEST 2400E2 2800E2 2400E 2800E Backup Restore BIOS Configuration window for PRIMQUEST 2800B2 2800B 1 6 2 1 Backup Restore MMB Configuration window You can back up and restore the MMB configuration information from the Backup Restore MMB Configuration window FIGURE 1 113 Backup Rest...

Page 277: ...utton This sends the file to the MMB To confirm restoration the MMB Configuration File Information dialog box appears 4 Click the OK button in the MMB Configuration File Information dialog box This restores the MMB configuration information 5 The MMB is rebooted to enable the restored data Message The following table lists the messages displayed in this window Message Number Message I_00054 Restor...

Page 278: ...cription Backup Backs up the BIOS configuration information Cancel Cancels backup of the BIOS configuration information 1 Menu Operation Maintenance Backup Restore Configuration Backup BIOS Configuration 2 Window Operations 1 Select the radio button of the partition to which to back up BIOS configuration information Then click the Backup button A save destination dialog box appears 2 Select the sa...

Page 279: ...artition not defined E_00098 Failed to get the partition status E_00098 Failed to get the screen information For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 1 6 2 3 Restore BIOS Configuration window for PRIMEQUEST 2400E2 2800E2 2400E 2800E This window is displayed only in PRIMEQUEST 2400E 2800E You can restore BIOS configuration informa...

Page 280: ...rent BIOS version installed on the partition TABLE 1 136 Buttons in the Restore BIOS Configuration window 2 Buttons Description Restore Restores the BIOS configuration information file Cancel Cancels restoration of the BIOS configuration file 1 Menu Operation Maintenance Backup Restore Configuration Restore BIOS Configuration 2 Window Operations 1 Click the Browse button in the Restore BIOS Config...

Page 281: ...ailed Size of uploaded file is zero E_00039 Uploading failed E_00057 Specified file can not restore E_00058 File format error E_00065 Failed to restore the BIOS Configuration E_00067 Can t restore the BIOS Configuration Please power off the partition s For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 Backup Restore BIOS Configuration win...

Page 282: ...up date _ BIOS version dat Restoring BIOS configuration information 1 Confirm that the system has completely stopped 2 Click the Browse button to select the backup file of the BIOS configuration 3 Click the Restore button This sends the file to the MMB To confirm restoration the BIOS Configuration File Information dialog box appears 4 Click the OK button in the BIOS Configuration File Information ...

Page 283: ...nance Wizard window has a wizard to support maintenance of units This window is designed for maintenance personnel 1 Menu Operation Maintenance Maintenance Wizard 1 6 4 REMCS menu You can operate and configure REMCS from the REMCS menu For details on REMCS see the PRIMEQUEST 2000 Series REMCS Installation Manual CA92344 0542 ...

Page 284: ...0537 If the error could not be resolved contact your sales representative or repairs assistance service Confirm the model name and serial number shown on the label affixed on the main unit and report it 1 7 1 System Status window System Status window shows the status of entire PRIMEQUEST 2800B2 2800B model The contents displayed may differ depending on the configuration of the unit You can also di...

Page 285: ...g the detailed status However for units which are not mounted there is no window showing the details Therefore these units are not linked TABLE 1 138 Items displayed in System Status Window Items Description Power Supply Shows the status of PSU Fans Shows the status of FAN Temperature Shows the status of temperature sensor SB 0 SB 3 Shows the status of system board IOU 0 IOU 3 Shows the status of ...

Page 286: ...the System Event Log window in chronological order Maximum 32000 events can be stored in system event log When the entries in the system event log are full oldest event log is deleted and latest event log is stored in system event log FIGURE 1 119 System Event Log window In the System Event Log Window only the contents and not the title in the table can be scrolled When there are no events to be d...

Page 287: ...ch part number and serial number of each unit can be referenced showing detailed status of each unit Part Number Displays the part number stored in system event log If is displayed Event ID Displays the ID 8 digits in hexadecimal system for identifying contents of Event For details on the allocation of the Event ID see Chapter 2 MMB Message of PRIMEQUEST 2000 Series Message Reference CA92344 0540 ...

Page 288: ...tton a message showing I_00417 Are you sure is displayed Click OK button 2 System Event Log Collect window appears and the link to system event log information collected in advance is displayed 3 Click Collect button to collect the latest system event log A message showing I_00417 Are you sure is displayed Click OK button Progress window appears while the system event log information is collected ...

Page 289: ...ndow Click Filter button on the System Event Log window The System Event Log Filtering Condition window for entering filtering conditions appears The filtering conditions of events which are displayed in System Event Log window can be set in the System Event Log Filtering Condition window FIGURE 1 121 System Event Log Filtering Condition Window ...

Page 290: ...e set Select the Source to be displayed Default setting is All Sort by Date Time Specifies either display by new order or display by old order by using the radio button New event first Old event first The default setting is New event first Start Date Time Specifies either display from recent event or specify the time by using the radio button First event Display by recent event Specified Time Spec...

Page 291: ...o System Event Log window by clicking the Cancel button Default Setting Selected value returns to the default value Message This section describes the messages to be displayed on this window Message Number Message W_00413 Nothing is selected W_00414 Invalid Date Format W_00426 Invalid Values Specified W_00434 Invalid Time Format W_00441 Range over error I_00417 Are you sure I_00468 Are you sure yo...

Page 292: ...E2 2800E2 2400E 2800E model Refer to chapter 1 2 3 1 7 4 System Information Window System Information window displays the information such as name of the systems and name of the products etc related to the PRIMEQUEST 2800B2 2800B model Moreover names and Asset Tag Property management number corresponding to the PRIMEQUEST 2800B2 2800B model Chassis can be set FIGURE 1 122 System Information Window...

Page 293: ... displayed Asset Tag Property administration information Asset Tag is displayed User with the administrator privilege can change Asset Tag information Maximum 32 characters can be entered No default value Core Max Core Display the CPU core number and Max Core number included in the system The Max Core number contains the number of Disable core Remarks Degenerated CPU is not included in the number ...

Page 294: ...tting completed W_00431 Invalid character included W_00407 Input characters are too long For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 In the Operation Log window only the table contents can be scrolled without scrolling the title of the table When there is no event to be displayed a message There is no Event Logs would be displayed i...

Page 295: ...539 04 1 7 5 Firmware Information Window Latest version number of applied Firmware information of the Firmware version which is operating inside the system and the information of the Firmware version with backup is displayed on the Firmware Information window FIGURE 1 123 Firmware Information Window ...

Page 296: ... format Minor Version 1Byte data BCD format This data is displayed as follows X YY X displays Major version in decimal 0 255 Y displays Minor version as it is by double digit in BCD format Binary coded decimal 00 99 Version bank2 Firmware Version of bank2 is displayed Version display format Same as bank1 Unified Firmware version Displays firmware version of target unit Firmware maintains version i...

Page 297: ...ations 1 7 System Menu for PRIMEQUEST 2800B2 2800B 296 CA92344 0539 04 1 7 6 System Setup Window In System Setup window Power supply of PRIMEQUEST 2800B2 2800B model and restoration action etc can be set FIGURE 1 124 System Setup Window ...

Page 298: ...the partition If the power was off the partition power stays off Schedule Sync If the partition is in the operating time zone power of partition turns on automatically depending on the schedule operations at the time of restoration of power attention The schedule set with Special is applied only on the specified day Default setting is Restore System Power On Delay Sets the standby time utill power...

Page 299: ... is the maximum value of each model TABLE 1 147 System Setup window button Buttons Description Apply When items such as Power Feed Mode and Power Restore Policy are specified and Apply button is clicked the information is set Cancel When Cancel button is clicked returns to the original status without setting the changed or input items 1 Menu Operation System System Setup 2 Window Operations Specif...

Page 300: ... are not supported sometimes power Off is not possible Since these depend on the specifications of the operating system and applications for details refer to the operating system and application specifications FIGURE 1 125 Power Control Window 1 Select the process executed for the system from Pull down menu of Power Control Then click the Apply button Dialog box for confirmation appears 2 Click th...

Page 301: ...ng booted Operating system Running Operating system running state Operating system Shutdown Operating system shutting down Panic Panic Only in RHEL Power Off In Progress Partition power off is in process Fatal Stopped Dumping The dumping is being output Halt Halting Remarks When SVAS Server View Agentless Service is not installed to system the display is not switched over in Operating system Runni...

Page 302: ...ration of the shutdown instruction for the operating system by Power Off on the partition In case enforced power off has been specified the specified time 1 9 minutes can be set The system is forcibly powered off when the specified time has lapsed The default setting of check box is Off Boot Selector Specifies the boot device for which the Boot Manager setting of BIOS is Override temporarily Selec...

Page 303: ...settings Message This section describes the messages to be displayed on this window Message Number Message E_00141 Unable to power on the System E_00142 Unable to power off the System E_00002 Command Failed E_00144 Unable to power off on the System E_00145 Unable to reset the System E_00146 Unable to generate an NMI interrupt in the System E_00143 Unable to forcibly power off the System E_00091 Fo...

Page 304: ...lay is delayed about from six seconds up to 8 seconds than the time reserved for the scheduled operations The shutdown instructions from MMB to OPERATING SYSTEM take certain time from the set time However the following interval times may be changed under the various conditions like setting and the configuration Interval time until shutdown instructions reaches OS from MMB Interval time until MMB n...

Page 305: ...to Power Off Because System does not do Power On in Power On Delay Schedule Power Off is disregarded Moreover when OS does not accept the Shutdown demand Power Off is not done TABLE 1 150 Display Items and Setting Items of Schedule Control Window Items Description Schedule Control Sets whether schedule operation is done for system On Off Default setting is Off Number of schedules Displays the numb...

Page 306: ...nces of system power On Off schedule can be recorded in the Schedule list Window FIGURE 1 127 Schedule List Window Schedule will appear in chronological order of the start date of the period If the start date are the same the schedule appears in the sequence in which it is listed Remarks If the Type is Weekly the start date is considered to be Oneday ...

Page 307: ...ays of week in Weekly Sun Sat The period in Monthly The specific month and day in Special Term Displays the period of the schedule according to the type and the pattern of the schedule Daily Starting month and date and ending month and date Weekly Starting month and ending month Monthly Starting month and ending month Default setting is as follows Daily From Jan 1 To Jan 1 Note It is executed only...

Page 308: ...is to be added newly 1 Click Add button Add Edit Schedule window appears 2 Add the schedule to the Add Edit Schedule window If the schedule is to be changed 1 Select an existing schedule with Radio button 2 Click Edit button Add Edit Schedule window appears 3 Changes an existing schedule in Add Edit Schedule window If the schedule is to be deleted 1 Select the schedule with Radio button 2 Click Re...

Page 309: ...dule window In Add Schedule window the schedule of Power On Off for each partition can be added newly In Edit Schedule window an existing schedule can be changed The window items of Add Schedule window and Edit Schedule window are common In this section an explanation is given by using the Add Schedule window FIGURE 1 128 Schedule List Window ...

Page 310: ...To 1 Specified date Jan 1 Term Specify the period of the schedule according to the type and pattern of the schedule Daily Starting month and date and ending month and date Weekly Starting month and ending month Monthly Starting month and ending month Default settings are as follows Daily From Jan 1 To Jan 1 Weekly From Jan To Jan Monthly From Jan To Jan On Time On the specified execution date set ...

Page 311: ...on describes the messages to be displayed on this window Message Number Message I_00013 Setting completed W_00414 Invalid Date Format W_00415 The duplicate On Off Time is found W_00416 Both On Off Time are disabled For details on the messages displayed on the window see PRIMEQUEST 2000 Series Message Reference CA92344 0540 ...

Page 312: ... Display Items and Set Items of IPv4 Console redirection Setup Window Items Description IP Address Enters the IP address for the Console Redirection of the partition Specify an IP address of the same segment as the virtual IP address used to access the MMB Web UI see 1 5 2 Network Interface Menu Note that this IP address must be different from that virtual IP address Default is 0 0 0 0 Subnet Mask...

Page 313: ...he subnet mask are entered and it is set whether video redirection virtual media can be used 2 Apply button is clicked Message This section describes the messages to be displayed on this window Message Number Message W_00432 Invalid IP Address specified W_00433 The duplicate IP address was found I_00417 Are you sure 1 7 9 2 IPv6 Console Redirection Setup window The IP address settings for accessin...

Page 314: ...c acquisition When IPv6 address is automatically acquired the Auto button is clicked IP address and prefix length are automatically acquired and overwritten TABLE 1 159 IPv6 Console redirection Setup Window Buttons Buttons Description Auto When you Click Auto button IP address and prefix length is automatically displayed Apply When you click the Apply button video direction of the system virtual m...

Page 315: ...ment Setup Window In the Power Management Setup window Power Saving can be set in the system Power Saving can be set only when the Power save Control as system is Enable When the System Power Save setting is Disable then the display of this screen is shown as gray and cannot be set FIGURE 1 131 Power management Setup window ...

Page 316: ...able and shows gray color when Disable Default is 5 minutes Action reaching Power Save Executes the operation setting in the system after the Limit threshold excess stand by time Continue Continues operation for the system under operation Power Off Power Off is done for the system under operation Force Power Off Force Power Off is done for the system under operation Displays a valid item when Powe...

Page 317: ...curs and OS shuts down The number of times can be set up to 0 10 times When 0 is specified it does not retry Default is five times Action after exceeding Restart tries Repeat the restart by Watchdog Timeout and sets the action when the above mentioned retry number is exceeded The actions are as below Stop rebooting and Power Off Reboot process is stopped power supply of partition is cut off Stop r...

Page 318: ... of Restart Tries Action after exceeding Restart tries are specified If Cancel Boot Watchdog is selected as On Boot Watchdog is cancelled Cancel Does not set the information and returns to the original state 1 Menu Operation System ASR Control 2 Window Operations 1 Every item is set 2 Apply button is clicked Specified information is set Also if the Cancel Boot Watchdog check box is selected as On ...

Page 319: ... Redirection Setup window selection is possible only when Enabled when Disabled the check box cannot be checked 1 Menu Operation System Console Redirection 2 Window Operations None Message This section describes the messages to be displayed on this window Message Number Message W_00413 Nothing is selected W_00472 Unable to get the reserved WEB Session information due to WEB Session Max over W_0047...

Page 320: ...gain FIGURE 1 134 Mode Window When the Apply button is clicked while the system is powered on a warning dialog box W_00487 Unable to change the mode because this system is powered on is displayed When the system is already powered off the settings are reflected without displaying the dialog box The LAN Device Mode is displayed in IOU Unit comprised in the partition specified by the LAN Device Mode...

Page 321: ...Capacity Keep Mode Shows maintenance of memory capacity Memory Mirror RAS Mode setting Sets the Memory Mirror Mode for system Mirror Keep Mode Capacity Keep Mode Enables the settings after rebooting the system As these items are enabled only when the Mode is set when Mode is not set they are disabled Default setting is Mirror Keep Mode Memory Sparing Mode current status Only for PRIMQUEST 2800B2 D...

Page 322: ...fault setting is Enabled WOL disabled 1 Menu Operation System Mode 2 Window Operations 1 Specify respective Mode and click the Apply button Confirmation dialog box is displayed 2 Click the Ok button Message This section describes the messages to be displayed on this window Message Number Message E_00089 Mode setting failed E_00090 Power Control Reset setting failed E_00xxx Unable to register the s...

Page 323: ...nu consists of the menus in each SB unit The menu of uninstalled SB is not displayed The format of window and operating method are same for each menu therefore only one menu is explained here SB x Window SB x window displays the status of SB x board and the settings of SB x board can be carried out FIGURE 1 135 SB x Window 1 ...

Page 324: ...MMB Web UI Web User Interface Operations 1 7 System Menu for PRIMEQUEST 2800B2 2800B 323 CA92344 0539 04 FIGURE 1 136 SB x Window 2 FIGURE 1 137 SB x Window 3 ...

Page 325: ...2344 0539 04 FIGURE 1 138 SB x Window 4 FIGURE 1 139 SB x Window 5 The CPU and DIMM row that is not mounted is displayed in gray background The Status clear button and a message Click the Status Clear Button to clear the status are not displayed for a user who does not have setting privileges ...

Page 326: ...s Standby Standby status Part Number Displays the part number of the SB Serial Number Displays the serial number of the SB Location LED Indicates the display status of the Location LED The display status consists of the following conditions On The light is on Off The light is off On Off and blinking of the Location LED can be controlled by clicking the respective On Off Blink buttons CPUs CPU 0 CP...

Page 327: ...wn Data Rate Displays Data Rate of DIMM DDR3 1066 1333 1600 For PRIMQUEST PRIMQUEST 2800B DDR4 1333 1600 1866 For PRIMQUEST PRIMQUEST 2800B2 There is no display when the DIMM status is Not present Not supported or Unknown Part Number Displays the part number of DIMM There is no display when the DIMM status is Not present Not supported or Unknown Serial Number Displays the serial number of DIMM The...

Page 328: ...1VL P1 8VL P1 5VL P1 0VL P1 8V_CPU VDDQ_DIMM 1A P1 0V_JC 0A P1 5V_PCH P1 1V P0 9V_PCIEX 0 P1 8V_PCIEX 0 P0 9V_PCIEX 1 P1 8V_PCIEX 1 P12V 0 P5V P3 3V P1 35V_CPU 0 P1 35V_CPU 1 VCC_CPU 0 VSA_CPU 0 VTT_CPU 0 VDDQ_DIMM 0A VDDQ_DIMM 0B P1 0V_JC 0B P1 5V_JC 0AB P1 35V_JC 0AB VCC_CPU 1 VSA_CPU 1 VTT_CPU 1 VDDQ_DIMM 1B P1 0V_JC 1A P1 0V_JC 1B P1 5V_JC 1AB P1 35V_JC 1AB VDDQ_DIMM 0C VDDQ_DIMM 0D P1 0V_JC 0...

Page 329: ...Q_DIMM 0D P1 05V_JC 0CD P1 5V_JC 0CD P1 35V_JC 0CD VDDQ_DIMM 1C VDDQ_DIMM 1D P1 05V_JC 1CD P1 5V_JC 1CD P1 35V_JC 1CD P2 5V_DIMM 0AB P2 5V_DIMM 1AB P2 5V_DIMM 0CD P2 5V_DIMM 1CD P12V 1 P12V 2 P12V 3 P12V 4 P12V 0F Voltage Displays the current power voltage Threshold Warning Low High Lower and upper limits of the warning level voltage Displays when the threshold is not set Displays the power voltag...

Page 330: ...es the following menus for each IOU IOU 0 IOU 3 The menu is not displayed for the IOU which is not installed Since the window and the operating method are same for each menu only one menu is described here IOU x Window IOU x window displays the status of the IOU installed in IOU x slot In addition IOU can be set FIGURE 1 140 IOU x Window 1 ...

Page 331: ...MMB Web UI Web User Interface Operations 1 7 System Menu for PRIMEQUEST 2800B2 2800B 330 CA92344 0539 04 FIGURE 1 141 IOU x Window 2 FIGURE 1 142 IOU x Window 3 ...

Page 332: ...LED can be controlled by clicking On Off button On board LAN LAN Displays the LAN number MAC Address Displays the MAC Address for GbE that is being installed on the IOU Displays Unknown when MAC Address is not clear DU connection PCIC Displays PCIC for DU connection on the IOU Status Displays the status of connection with the DU OK Not connected Incorrect connection Connector Displays the destinat...

Page 333: ...atus of PCIeSW OK Warning Failed PCIeSW 1 Same as PCIeSW 0 Voltage Voltage Sensor Displays the Voltage sensor type P1 8VL 1 P1 0VL 1 P2 5VL 2 P1 2VL 2 P0 8VL 2 P0 67VL 2 P3 3V 3 P1 8V_PCIEX 0 1 P1 8V_PCIEX 1 1 P1 8V 2 P0 9V_PCIEX 0 3 P0 9V_PCIEX 1 3 1 IOUL 2 IOUF 3 IOUL IOUF commonness Voltage Displays the current power voltage Threshold Warning Low High Lower and upper limits of the warning level...

Page 334: ... the same as the PRIMEQUEST 2400E2 2800E2 2400E 2800E model Refer to chapter 1 2 15 1 7 17 OPL Window As for the display the operation is the same as the PRIMEQUEST 2400E2 2800E2 2400E 2800E model Refer to chapter 1 2 16 1 7 18 MMB Window In MMB Window information related to MMB can be displayed and the Location LEDs can be set FIGURE 1 143 MMB x Window 1 ...

Page 335: ...MMB Web UI Web User Interface Operations 1 7 System Menu for PRIMEQUEST 2800B2 2800B 334 CA92344 0539 04 FIGURE 1 144 MMB x Window 2 ...

Page 336: ...lowing are the various display status On During power on Off During power off On Off of the Location LED can be controlled by clicking On Off buttons Reset MMB Resets the MMB if this check box is checked Voltage Displays the current power voltage Threshold Warning Low Hig h Lower and upper limits of the warning level voltage Displays when the threshold is not set Displays the power voltage in the ...

Page 337: ...oftware e g Windows HyperTerminal on the terminal Then configure the terminal software as follows TABLE 2 1 Terminal software setting values Parameter Value Bits second 19200 Data bits 8 Parity None Stop bits 1 Flow control None Emulation VT100 3 The login prompt appears Enter your user name and password to log in 2 1 2 Access via the management LAN interface You can access the CLI of the MMB via ...

Page 338: ...n Permitted Removes a partition component show partition configuration Permitted Displays the partition configuration show partition status Permitted Displays the partition status set partition home Permitted Sets the Home SB show partition home Permitted Displays the Home SB set partition memory_operation_mode Permitted Sets Memory operation mode show partition memory_operation_mode Permitted Dis...

Page 339: ...ce show http Permitted Displays the http service enabling setting show https Permitted Displays the https service enabling setting show ssh Permitted Displays the ssh service enabling setting show telnet Permitted Displays the telnet service enabling setting set http_port Permitted Sets the http port number set https_port Permitted Sets the https port number set ssh_port Permitted Sets the ssh por...

Page 340: ...ended Partitioning mode show partition extended_partitioning _mode Permitted Displays Extended Partitioning mode set partition dimm_excl_mode Permitted Sets DIMM exclusion allocation mode show partition dimm_excl_mode Permitted Displays DIMM exclusion allocation mode set partition skt_binding_mode Permitted Sets CPU Socket fixation allocation mode show partition skt_binding_mode Permitted Displays...

Page 341: ...isk rebuilding cancel raid rebuild Permitted Cancel disk rebuilding start raid copyback Permitted Start disk copyback cancel raid copyback Permitted Stop disk copyback start raid mdc Permitted Start make data consistency MDC cancel raid mdc Permitted Cancel MDC start raid patrol Permitted Start RAID patrol cancel raid patrol Permitted Cancel RAID patrol make raid online Permitted Make disk online ...

Page 342: ...d Displays Memory operation at Mode set partition pci_address_mode Permitted Sets PCI bus number allocation mod show partition pci_address_mode Permitted Displays PCI bus number allocation mod set partition lan_device_mode Permitted Sets LAN device mode show partition lan_device_mode Permitted Displays LAN device mode show partition mirror_mode Permitted Displays the Mode setting set partition nam...

Page 343: ... the telnet port number clear access_control Clears the access control setting show access_control Displays the access control setting clear ssh_key Clears the SSH public key download ssh_key Downloads the SSH public key ping Permitted Pings the target show ntpq Permitted NTP inquiry ntpq p executed Account management passwd Permitted Changes a password who Permitted Displays the login user Firmwa...

Page 344: ...ove extended_partition iou Removes IOU resource to Extended Partitioning remove extended_partition pcibox Removes PCI_Box resource to Extended Partitioning set partition extended_socket_mode Permitted Sets Extended Socket mode show partition extended_socket_mode Permitted Displays Extended Socket mode set partition extended_socket_zone Sets Extended Socket zone show partition extended_socket_zon P...

Page 345: ...itted Make disk offline replace raid missing_drive Permitted Replace missing drive show raid adapter Permitted Display RAID adapter information show raid disk_enclosure Permitted Display disk enclosure information show raid physical_drive Permitted Display disk information show raid physical_drive_count Permitted Display disk counts show raid logical_drive Permitted Display logical drive informati...

Page 346: ...or_ras_mode Permitted Sets Memory operation at Mode show partition memory_mirror_ras_mode Permitted Permitted Displays Memory operation at Mode set partition pci_address_mode Permitted Sets PCI bus number allocation mod show partition pci_address_mode Permitted Permitted Displays PCI bus number allocation m od set partition lan_device_mode Permitted Sets LAN device mode show partition lan_device_m...

Page 347: ...p port number set https_port Sets the https port number set ssh_port Sets the ssh port number set telnet_port Sets the telnet port number show http_port Permitted Permitted Displays the http port number show https_port Permitted Permitted Displays the https port number show ssh_port Permitted Permitted Displays the ssh port number show telnet_port Permitted Permitted Displays the telnet port numbe...

Page 348: ...ration status Permitted Permitted Displays DR progress state Extended Partitioning related set partition extended_partitioning _mode Permitted Sets Extended Partitioning mode show partition extended_partitioning _mode Permitted Permitted Displays Extended Partitioning mode set partition dimm_excl_mode Permitted Sets DIMM exclusion allocation mode show partition dimm_excl_mode Permitted Permitted D...

Page 349: ...sk LEDs for logical drive start raid locate_encl Permitted Start locate disk enclosure LED stop raid locate_encl Permitted Stop locate disk enclosure LED start raid rebuild Permitted Start disk rebuilding cancel raid rebuild Permitted Cancel disk rebuilding start raid copyback Permitted Start disk copyback cancel raid copyback Permitted Stop disk copyback start raid mdc Permitted Start make data c...

Page 350: ...t Mode set partition pci_address_mode Sets PCI bus number allocation mod show partition pci_address_mode Permitted Displays PCI bus number allocation mod set partition lan_device_mode Sets LAN device mode show partition lan_device_mode Permitted Displays LAN device mode show partition mirror_mode Permitted Displays the Mode setting set partition name Sets the partition name show partition name Per...

Page 351: ...port number clear access_control Clears the access control setting show access_control Displays the access control setting clear ssh_key Permitted Clears the SSH public key download ssh_key Permitted Downloads the SSH public key ping Permitted Pings the target show ntpq Permitted NTP inquiry ntpq p executed Account management passwd Permitted Changes a password who Permitted Displays the login use...

Page 352: ..._partition sb Removes SB resource to Extended Partitioning remove extended_partition iou Removes IOU resource to Extended Partitioning remove extended_partition pcibox Removes PCI_Box resource to Extended Partitioning set partition extended_socket_mode Sets Extended Socket mode show partition extended_socket_mode Permitted Displays Extended Socket mode set partition extended_socket_zone Sets Exten...

Page 353: ...e replace raid missing_drive Replace missing drive show raid adapter Permitted Display RAID adapter information show raid disk_enclosure Permitted Display disk enclosure information show raid physical_drive Permitted Display disk information show raid physical_drive_count Permitted Display disk counts show raid logical_drive Permitted Display logical drive information show raid logical_drive_count...

Page 354: ...Mode set partition pci_address_mode Sets PCI bus number allocation mod show partition pci_address_mode Permitted Displays PCI bus number allocation mod set partition lan_device_mode Sets LAN device mode show partition lan_device_mode Permitted Displays LAN device mode show partition mirror_mode Permitted Displays the Mode setting set partition name Sets the partition name show partition name Permi...

Page 355: ...ort number clear access_control Clears the access control setting show access_control Displays the access control setting clear ssh_key Permitted Clears the SSH public key download ssh_key Permitted Downloads the SSH public key ping Permitted Pings the target show ntpq Permitted NTP inquiry ntpq p executed Account management passwd Permitted Changes a password who Permitted Displays the login user...

Page 356: ...partition sb Removes SB resource to Extended Partitioning remove extended_partition iou Removes IOU resource to Extended Partitioning remove extended_partition pcibox Removes PCI_Box resource to Extended Partitioning set partition extended_socket_mode Sets Extended Socket mode show partition extended_socket_mode Permitted Displays Extended Socket mode set partition extended_socket_zone Sets Extend...

Page 357: ... replace raid missing_drive Replace missing drive show raid adapter Permitted Display RAID adapter information show raid disk_enclosure Permitted Display disk enclosure information show raid physical_drive Permitted Display disk information show raid physical_drive_count Permitted Display disk counts show raid logical_drive Permitted Display logical drive information show raid logical_drive_count ...

Page 358: ...ioning 2 5 Unsupported 4 11 1 The state of 0 3 can be specified for PRIMEQUEST 2400E2 Model in the case that Memory Scale up Board is used If the specified value falls outside the valid range the system displays an error message and does not process the command Messages The following messages are common to all the commands If the specified CLI parameter character string is an incorrect parameter t...

Page 359: ...2 30 set partition pci_address_mode 2 2 31 set partition pci_express_mode 2 2 32 set ssh 2 2 33 set ssh_port 2 2 34 set telnet 2 2 35 set telnet_port 2 2 36 set timezone 2 2 37 set partition extended_partitioning_mode 2 2 38 set partition dimm_excl_mode 2 2 39 set partition skt_binding_mode 2 2 40 add extended_partition sb 2 2 41 add extended_partition iou 2 2 42 add extended_partition pcibox 2 2 ...

Page 360: ...cl 2 2 64 stop raid locate_encl 2 2 65 start raid rebuild 2 2 66 cancel raid rebuild 2 2 67 start raid copyback 2 2 68 cancel raid copyback 2 2 69 start raid mdc 2 2 70 cancel raid mdc 2 2 71 start raid patrol 2 2 72 cancel raid patrol 2 2 73 make raid online 2 2 74 make raid offline 2 2 75 replace raid missing_drive This section describes how to use these commands ...

Page 361: ... with user 3 Usage example Example In PRIMEQUEST 2800E when SB 3 is to be added in Partition 2 add partition 2 SB 3 Are you sure you want to add SB 3 to Partition 2 Y N Y Adding SB 3 to Partition 2 has been completed successfully Example In PRIMEQUEST 2800E when IOU 1 is to be added in Partition 2 add partition 2 IOU 1 Are you sure you want to add IOU 1 to Partition 2 Y N Y Adding IOU 1 to Partiti...

Page 362: ... the specified SB to the partition due to DIMM composition abnormal Unable to add the specified SB to the partition due to SB composition abnormal Unable to add the specified SB to the partition due to DIMM does not satisfy requirements of Mode Unable to change partition configuration because this partition is powered on Unable to add the specified SB to the partition due to Dynamic Reconfiguratio...

Page 363: ...MC However the following messages are displayed when the following console command is executed when other users have already executed the console command and the Text Console connection to BMC can be done compulsorily by inputting as Y In that case the compulsion cutting is done as for the console command under the connection Console redirection already in use If needed the current user can be dis...

Page 364: ...e to execute this command because you have not authority to operate this partition 2 2 5 download ssh_key Downloads the public key which is used in SSH Public Key Authentication of logged in users from the specified server and then registers the key Input method of URL is as follows http host path file ftp host path file Privilege User 1 Input format download ssh_key URL 2 Option None 3 Usage exam...

Page 365: ...re it is necessary to specify the partition Partitions are specified as follows all All defined partitions specified Specifies Partition numbers by delimiting with comma Specifies with the range of partition number force Shows that the power of the partition turns off forcefully without shutting down the operating system of partition 3 Usage example None 4 Message The following table lists the mes...

Page 366: ...fied partition cannot be operated Privilege Administrator Operator Partition Operator Only the partition to be managed 1 Input format power on partition all partition partition 2 Option Partition Turn on the power of the partition which specifies the partition number When there is no power supply to the chassis before turning on the power of the partition turn on the power supply of the chassis an...

Page 367: ...rmal SB composition Unable to power on the partition d Command Failed Code 0x 04X 0x 02X Unable to execute this command on a standby MMB Unable to power on the partition d due to no Home SB Unable to execute this command because the system is under maintenance Unable to execute this command because the Partition x is under maintenance The Power On failed because of switching the Home SB Please exe...

Page 368: ...Partition is number specified as follows Partition numbers are separated by comma Specifies with the range of partition number quiet The command is executed without interactive operation with the user 3 Usage example Example When sadump is specified to Partition 1 by Administrator Authority Administrator sadump partition 1 Are you sure you want to sadump to Partition 1 Y N Y Administrator 4 Messag...

Page 369: ... must be specified Partition is number specified as follows Partition numbers are separated by comma Specifies with the range of partition number quiet The command is executed without interactive operation with the user 3 Usage example Example When reset is specified to Partition 1 by Administrator Authority Administrator reset partition 1 Are you sure you want to Reset to Partition 1 Y N Y Admini...

Page 370: ...number must be specified Partition is number specified as follows Partition numbers are separated by comma Specifies with the range of partition number quiet The command is executed without interactive operation with the user 3 Usage example Example When NMI is specified in Partition 1 by Administrator privilege Administrator nmi partition 1 Are you sure you want to NMI to Partition 1 Y N Y Admini...

Page 371: ...ion 2 in PRIMEQUEST 2800E remove partition 2 EXT_PART 4 Are you sure you want to remove Extended Partitioning 4 from Partition 2 Y N Y Removing Extended Partitioning 4 from Partition 2 has been completed successfully 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure...

Page 372: ...quiet 2 Option quiet Command is executed without interacting with the user 3 Usage example None 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure to continue set active mmb y n The specified parameter is invalid set active_mmb failed Unable to execute this command o...

Page 373: ...the power supply The value set at that instant is reflected without displaying the above mentioned message When Memory Scale up Board is built into specified Partition the specified partition cannot be operated Privilege Administrator 1 Input format set partition dynamic_reconfiguration partition disable enable quiet 2 Option quiet The command is executed without interactive operation to User 3 Us...

Page 374: ...dress is invalid The specified parameter is invalid The specified IP address is duplicated The specified IP address is loopback address Unable to execute this command on a standby MMB 2 2 16 set gateway_ipv6 Default gateway of IPv6 is set If automatic setting is executed only auto is specified in option Privilege Administrator 1 Input format In case of manual setting Set gateway_ipv6 ip address In...

Page 375: ... format Characters which can be entered are as follows a z A Z 0 9 Hyphen Dot However following conditions must be observed The first character must be alphanumeric character Hyphen Dot cannot be used as first character Default value is PRIMEQUEST Product Serial Number Example When serial number is 1020516004 PRIMEQUEST1020516004 Privilege Administrator 1 Input format set hostname hostname domain ...

Page 376: ...eference CA92344 0540 Unable to execute this command on a standby MMB 2 2 19 set http_port Sets a port accepting HTTP session 8081 is the default The specifiable port numbers in port are in the range of 1024 65535 80 is the standard port Privilege Administrator 1 Input format Set http_port port 2 Option None 3 Usage example None 4 Message The following table lists the messages which are displayed ...

Page 377: ...ssage Reference CA92344 0540 Unable to execute this command on a standby MMB 2 2 21 set https_port Sets a port accepting HTTPS messages 432 is the default 432 1024 65535 are specifiable port numbers by port 443 is the standard port Privilege Administrator 1 Input format Set https_port port 2 Option None 3 Usage example None 4 Message The following table lists the messages which are displayed in th...

Page 378: ... address netmask 2 Option None 3 Usage example None 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified IP address is invalid The specified netmask is invalid The specified IP address is duplicated The specified IP address is loopback address Unable to execute this c...

Page 379: ... In case of manual setting set ipv6 2001 db8 caaf beef 206 29ff fele 482e 48 In case of automatic setting If GUID Device serial number 123456789abcdef0 set ipv6 auto 2001 xxxx xxxx xxxx xxxx 1234 5678 9abc def0 64 Are you sure to continue Y N 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference...

Page 380: ...ed In such case gateway address and SMTP address are set to 0 0 0 0 When settings in this command are invalid ip address is set to 0 0 0 0 Though the parameters other than ip address parameters are optional they are recommended to be 0 0 0 0 Privilege Administrator CE 1 Input format set maintenance_ip ip address netmask gateway address smtp address Indicates that there is no new line 2 Option None...

Page 381: ...t partition home partition SB SB 2 Option None 3 Usage example Example When setting SB 2 as Home in Partition3 set partition home 3 SB 2 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified SB number is invalid The specified S...

Page 382: ...ioned message is not displayed When the specified partition is an Extended Partitioning an error message is displayed and the specified partition cannot be operated Privilege Administrator Operator Partition Operator Only managed partition 1 Input format set partition lan_device_mode partition IOU wol_enable 2 Option quiet The command is executed without interactive operation to User 3 Usage examp...

Page 383: ...ettings are changed by this command power OFF ON is not required The value which is set is reflected instantly instead of displaying the above mentioned message Moreover also when values which are the same as the current values are set power ff on is not required and the above mentioned message is not displayed When the specified partition is an Extended Partitioning an error message is displayed ...

Page 384: ...artition memory_operation_mode It sets the Memory Operation Mode of the specified partition By default normal Mode invalid is set performance sets the Performance Mode normal sets the Normal Mode partial_mirror sets the Partial Mode full_mirror sets the Full Mode spare sets the Spare Mode For the partition which is already powered ON when the settings are performed by this command following messag...

Page 385: ... Mode is registered as the Reserved SB If you register this partition as a Mode Mode will be disabled when switching to a Reserved SB Are you sure to continue Y N y 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The setting will become effective the next time the partition po...

Page 386: ...ple Example When setting the name hogehoge to the Partition3 set partition name 3 hogehoge 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified partition name is invalid Partition x is not defined Unable to execute this comman...

Page 387: ...ied partition is an Extended Partitioning an error message is displayed and the specified partition cannot be operated Privilege Administrator Operator Partition Operator Only managed partition 1 Input format set partition pci_address_mode partition bus segment quiet 2 Option quiet The command is executed without interactive operation to User 3 Usage example Example When setting PCI Address Mode o...

Page 388: ...n 1 Input format set partition pci_ express_mode partition flexible fixed 2 Option None 3 Usage example Example When setting I O Mode of the Partition3 to fixed Mode set partition pci express mode 3 fixed pci_express_mode fixed 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 T...

Page 389: ...age Reference CA92344 0540 Unable to execute this command on a standby MMB 2 2 33 set ssh_port Set the port which receives the SSH session Default setting is 22 The port number which indicates the port are 22 1024 65535 Privilege Administrator 1 Input format set ssh_port port 2 Option None 3 Usage example None 4 Message The following table lists the messages which are displayed in this CLI For det...

Page 390: ... Message Reference CA92344 0540 Unable to execute this command on a standby MMB 2 2 35 set telnet_port Sets the port which receives the telnet connection Default setting is 23 Port numbers which can be set are 23 1024 65535 Privilege Administrator 1 Input format set telnet_port port 2 Option None 3 Usage example None 4 Message The following table lists the messages which are displayed in this CLI ...

Page 391: ... is set Privilege Administrator 1 Input format set timezone timezone 2 Option None 3 Usage example None 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified port number is invalid Time synchronization was requested to Standby MMB Unable to execute this command on a st...

Page 392: ...r Operator Partition Operator Management target partition only 1 Input format Set partition extended_partitioning _mode partition enable disable quiet 2 Option quiet Message is not displayed 3 Usage example Example when setting the Extended Partitioning mode of Partition 1 Enable set partition extended_partitioning _mode 1 enable 4 Message The following table lists the messages which are displayed...

Page 393: ...on is not in an Extended Partitioning an error message is displayed and the operation cannot be performed for the specified partition Privilege Administrator Operator Partition Operator Only managed partition 1 Input format set partition dimm_excl_mode partition enable disable quiet 2 Option quiet Message is not displayed 3 Usage example Example When setting DIMM exclusive allocation mode of the P...

Page 394: ...anged to two sockets When the specified partition is not in an Extended Partitioning an error message is displayed and the operation cannot be performed for the specified partition Privilege Administrator Operator Partition Operator Only managed partition 1 Input format set partition skt_binding_mode partition enable disable quiet 2 Option quiet Message is not displayed 3 Usage example Example Whe...

Page 395: ...e Operations 2 2 Setting Commands 394 CA92344 0539 04 Please try to change the mode after the partition is shutdown Unable to execute this command because you have not authority to operate this partition Partition x is not defined ...

Page 396: ... VGAUSB2 quiet 2 Option quiet The command is executed without interacting with the user 3 Usage example Example When three CPU cores are to be set to Partition 4 in PRIMEQUEST 2800E add extended_partition sb 4 CPU 3 Are you sure to continue adding three CPU Cores to Partition 4 Y N Y Adding three CPU Cores to Partition 4 has been completed successfully Example When 24G Memory is to be se to Partit...

Page 397: ...ng table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure you want to add s to Partition d Y N Adding s to Partition d has been completed successfully The specified partition number is invalid The specified SB number for PCI Slot is invalid The specified partition doesn t have SB d SB Parameter...

Page 398: ...SLOT 1 Are you sure to continue adding PCI Slot 1 of IOU 1 to Partition 4 Y N Y Adding PCI Slot 1 of IOU 1 to Partition 4 has been completed successfully Example When DU of IOU 1 is to be added to Partition 4 in PRIMEQUEST2800E add extended_partition iou 1 4 DU Are you sure to continue adding Disk Unit of IOU 1 to Partition 4 Y N Y Adding Disk Unit of IOU 1 to Partition 4 has been completed succes...

Page 399: ...ue adding PCISLOT 2 of PCIBOX 1 to Partition 4 Y N Y Adding PCISLOT 2 of PCIBOX 1 to Partition 4 has been completed successfully 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure you want to add s to Partition d Y N Adding s to Partition d has been completed success...

Page 400: ...AUSB2 Are you sure to continue removing VGA USB2 from Partition 4 Y N Y Removing VGA USB2 from Partition 4 has been completed successfully Example When PCI Express slot of SB 2 is removed from Partition 4 in PRIMEQUEST 2800E remove extended_partition sb 4 PCISLOT 2 Are you sure to continue removing PCI Slot of SB 2 from Partition 4 Y N Y Removing PCI Slot of SB 2 from Partition 4 has been complete...

Page 401: ...tition iou 14PCISLOT 1 Are you sure to continue removing PCI Slot 1 of IOU 1 from Partition 4 Y N Y Removing PCI Slot 1 of IOU 1 from Partition 4 has been completed successfully Example When DU of IOU 1 with PRIMEQUEST 2800E is removed from Partition 4 remove extended_partition iou 1 4 DU Are you sure to continue removing Disk Unit of IOU 1 from Partition 4 Y N Y Removing Disk Unit of IOU 1 from P...

Page 402: ...you sure to continue removing PCISLOT 2 of PCIBOX 1 from Partition 4 Y N Y Removing PCISLOT 2 of PCIBOX 1 from Partition 4 has been completed successfully 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure you want to remove s from Partition d Y N Removing s from Par...

Page 403: ...ition SB SB x quiet hotadd partition partition IOU IOU x quiet 2 Option quiet The command is executed without interacting with the user 3 Usage example Example When SB 3 is to be added to Partition 2 hotadd partition 2 SB 3 Are you sure to continue adding SB 3 to partition 2 Y N Y DR operation start 1 5 Assigning SB 3 to partition 2 2 5 Testing SB 3 3 5 Reconfiguring partition 2 4 5 Onlining added...

Page 404: ...dd SB due to DIMM mismatch Unable to power on the DR test partition Unable to power off the DR test partition Check DR Unit Error Unable to onlining the DR target bmc Unknown Error Code 0xXX The specified SB d is not supported Failed to execute hotadd partition command Unable to execute this command on a standby MMB Hot add SB d IOU d failed Failed to execute DR operation Fatal error occurred Unab...

Page 405: ...user 3 Usage example Example When SB 3 is removed from Partition 2 hotremove partition 2 SB 3 Are you sure to continue removing SB 3 from partition 2 Y N Y DR operation start 1 4 Offlining removed Memory CPU 2 4 Reconfiguring partition 2 3 4 Releasing SB 3 4 4 Removing SB 3 from partition 2 has been completed successfully Example When IOU 3 is removed from Partition 2 hotremove partition 2 IOU 3 A...

Page 406: ... d is not in specified Partition The specified SB d is home SB Unknown Error Code 0xXX Failed to execute hotremove partition command Unable to execute this command on a standby MMB Hot remove SB d IOU d failed Failed to execute DR operation Fatal error occurred Failed to execute DR operation Configuration is unrecovered Failed to execute DR operation Partition is stopped The specified IOU d has no...

Page 407: ...ists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure to continue updating IOU d to Partition d Y N The specified IOU d is not present The specified IOU d is power off The specified IOU d is not in specified Partition Unknown Error Code 0xXX Unable to execute this command on a standby MMB Failed to e...

Page 408: ...or Partition Operator Only managed partition 1 Input format set partition extended_socket_mode Extended Partitioning enable disable quiet 2 Option quiet The command is executed without interacting with the user 3 Usage example Example When you set Extended Socket mode of Extended Partitioning 4 to Enable set partition extended_socket_mode 4 enable 4 Message The following table lists the messages w...

Page 409: ...s which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified command is not supported error s Unable to execute this command on a standby MMB Failed to execute set partition extended_soket_zone command Unable to execute this command because the system is under maintenance Unable t...

Page 410: ...tion is restrained Privilege Administrator Operator Partition Operator Only managed partition 1 Input format set partition memory_sparing_mode Partition 1 2 auto quiet 2 Option quiet The command is executed without interacting with the user 3 Usage example Example When you set Rank of Memory Sparing Mode of Partition 3 to 1 set partition memory_sparing_mode 3 1 The setting will become effective th...

Page 411: ...6 512 or 1024 If this parameter is omitted 64 will be set ex stripe 1024 init This option specifies how you want to initialize the logical drive after the creation If this parameter is omitted no initialization will be done ex init fast force The command is executed without interactive operation with the user The mandatory options are disk and level and the other options are omitted The following ...

Page 412: ...e changed from default value when the logical drive is created If you want to change these parameter you should use modify raid policy command after created the logical drive These policies are set default values in the table below Parameter Default value Selectable values Read Policy No Read Ahead No Read Ahead Read Ahead Write Policy Write Back Write Back Write Through Force Write Back I O Polic...

Page 413: ...B 0 delete raid logical_drive SB 0 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not ...

Page 414: ...eliminate risk of losing cached data in case of power failure However it may result in slower performance Force Write Back The logical drive is in Write Back mode even if the battery is not present data loss may occur in the event of a power failure io This option number of IO policy from 0 Direct 1 Cached cache This option specifies number of drive cache policy from 0 Unchanged 1 Enable 2 Disable...

Page 415: ...10 50 or 60 ex level 5 force The command is executed without interactive operation with the user 3 Usage example Example When you modify RAID level of a logical drive to RAID 6 as RAID level migration RLM with additional disk attached to slot 3 modify raid logical_drive SB 0 0 target 0 disk 3 level 6 4 Message The following table lists the messages which are displayed in this CLI For details of th...

Page 416: ...bal hotspare to a disk attached to slot 0 create raid global_hotspare SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is inva...

Page 417: ... interactive operation with the user 3 Usage example Example When you assign a dedicated hotspare for the logical drive 0 to a disk attached to slot 0 create raid dedicated_hotspare SB 0 0 disk 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed ...

Page 418: ...e a hotspare to a disk attached to slot 0 delete raid hotspare SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s T...

Page 419: ...0 start raid locate_pd SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade number is re...

Page 420: ... 0 stop raid locate_pd SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade number is re...

Page 421: ...gned to the logical drive 1 start raid locate_ld SB 0 0 target 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found I...

Page 422: ...gned to the logical drive 1 stop raid locate_ld SB 0 0 target 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found In...

Page 423: ... SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade number is required in the paramete...

Page 424: ...SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade number is required in the parameter...

Page 425: ... attached to slot 0 start raid rebuild SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller ...

Page 426: ...k attached to slot 0 cancel raid rebuild SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controlle...

Page 427: ... 0 0 force The command is executed without interactive operation with the user 3 Usage example Example When you start coyback from a disk attached to slot 0 to a disk attached to slot 1 start raid copyback SB 0 0 src 0 dist 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The...

Page 428: ...isk attached to slot 0 cancel raid copyback SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified contro...

Page 429: ...0 start raid mdc SB 0 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Interna...

Page 430: ... 0 start raid mdc SB 0 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Intern...

Page 431: ...e following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Internal error d d The operation is failed s Unable ...

Page 432: ...The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Internal error d d The operation is failed s Unabl...

Page 433: ...hed to slot 0 make raid online SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not f...

Page 434: ...ched to slot 0 make raid offline SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not...

Page 435: ...Usage example Example When you replace a disk attached to slot 0 to the logical drive 0 which has missing drive replace raid missing_drive SB 0 0 disk 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too ...

Page 436: ...show ip 2 3 21 show ipv6 2 3 22 show hostname 2 3 23 show maintenance_ip 2 3 24 show ssh 2 3 25 show ssh_port 2 3 26 show telnet 2 3 27 show telnet_port 2 3 28 show network 2 3 29 show ntpq 2 3 30 who 2 3 31 help 2 3 32 netck traceroute 2 3 33 netck arptbl 2 3 34 netck arping 2 3 35 netck ifconfig 2 3 36 netck stat 2 3 37 show dynamic_reconfiguration status 2 3 38 show partition extended_partition...

Page 437: ...ow access_control SSH All Telnet All HTTP HTTPS IP Address 10 66 250 190 Netmask 24 SNMP All 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified command is invalid 2 3 2 show active_mmb Displays current Active MMB Privilege All 1 Input format show active_mmb 2 Option...

Page 438: ... date and time Privilege All 1 Input format show date 2 Option None 3 Usage example show date 2009 11 30 11 14 21 JST 4 Message None 2 3 4 show exit_code Displays the exit code of last execution command Privilege All 1 Input format show exit_code 2 Option None 3 Usage example power on all show exit_code 0 4 Message None ...

Page 439: ...o line feed 2 Option all Displays SB IOU which does not belong to all partitions and to any partition free Displays SB IOU which does not belong to any partition partition Displays the specified partition The specification method when multiple partitions are specified is as follows The partition number is delimited by a comma and is specified Partition number is specified within the range Remarks ...

Page 440: ... Dynamic Reconfiguration of the specified partition Privilege All 1 Input format show partition dynamic_reconfiguration partition 2 Option None 3 Usage example Example When the status of Dynamic Reconfiguration of Partition 3 is displayed show partition dynamic_reconfiguration 3 current disabled setting enabled 4 Message The following table lists the messages which are displayed in this CLI For de...

Page 441: ... partition home partition 2 Option None 3 Usage example When Home SB of partition 3 is displayed show partition home 3 SB 2 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified parameter is invalid Unable to execute this comma...

Page 442: ...de partition 2 Option None 3 Usage example Example When LAN Device Mode of IOU In example it is IOU 2 or IOU 3 from Partition 3 is displayed show partition lan_device_mode 3 iou 2 LAN Device enable WOL enable iou 3 LAN Device disable WOL disable 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Refere...

Page 443: ...None 3 Usage example When name of the partition 3 is displayed show partition name 3 hogehoge 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified parameter is invalid Unable to execute this command on a standby MMB Failed to ...

Page 444: ... None 3 Usage example Example When Memory Mirror RAS Mode of partition 3 is displayed show partition memory_mirror_ras_mode3 current mirror_keep setting capacity_keep 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified parame...

Page 445: ...tion memory_operation_mode partition 2 Option None 3 Usage example Example When Memory Operation Mode of partition 3 is displayed show partition memory_operation_mode3 current normal setting performance 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition nu...

Page 446: ...t bus setting segment 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified parameter is invalid Unable to execute this command on a standby MMB Failed to execute s command Failed to execute show partition command Partition x i...

Page 447: ...Privilege All 1 Input format show gateway 2 Option None 3 Usage example show gateway Gateway Address 10 1 2 1 4 Message None 2 3 15 show gateway_ipv6 Displays the IP address of default gateway of IPv6 set to the Management LAN Interface Privilege All 1 Input format show gateway_ipv6 2 Option None 3 Usage example show gateway_ipv6 Gateway Address fe80 1234 f3ff fe03 5666 4 Message None ...

Page 448: ...le of current HTTP Privilege All 1 Input format show http 2 Option None 3 Usage example show http HTTP disabled 4 Message None 2 3 17 show http_port Displays the port to which HTTP session is currently connected Privilege All 1 Input format show http_port 2 Option None 3 Usage example show http_port HTTP Port Number 8081 4 Message None ...

Page 449: ...of current HTTPS server Privilege All 1 Input format show https 2 Option None 3 Usage example show https HTTPS disabled 4 Message None 2 3 19 show https_port Displays the port to which HTTPS is currently connected Privilege All 1 Input format show https_port 2 Option None 3 Usage example show https_port HTTPS Port Number 432 4 Message None ...

Page 450: ...All 1 Input format show ip 2 Option None 3 Usage example show ip IP Address 10 1 2 124 Netmask 255 255 255 0 4 Message None 2 3 21 show ipv6 Displays the global address the prefix length for IPv6 set in the management LAN interface Privilege All 1 Input format show ipv6 2 Option None 3 Usage example show ipv6 IP Address Prefix 2000 2002 2003 2004 2005 2006 2007 2008 64 4 Message None ...

Page 451: ...me 2 Option None 3 Usage example show hostname HostName hogehoge fujitsu com 4 Message None 2 3 23 show maintenance_ip Displays the IP address of Maintenance port Privilege All 1 Input format show maintenance_ip 2 Option None 3 Usage example show maintenance_ip IP Address 192 168 1 10 NetMask 255 255 255 0 Gateway Address 192 168 1 1 SMTP Address 172 128 1 2 4 Message None ...

Page 452: ...sable of existing SSH server Privilege All 1 Input format show ssh 2 Option None 3 Usage example show ssh SSH disabled 4 Message None 2 3 25 show ssh_port Displays the port where SSH session is currently connected Privilege All 1 Input format show ssh_port 2 Option None 3 Usage example show ssh_port SSH Port Number 22 4 Message None ...

Page 453: ...g Telnet server Privilege All 1 Input format show telnet 2 Option None 3 Usage example show telnet Telnet disabled 4 Message None 2 3 27 show telnet_port Displays the port to which the Telnet session is currently connected Privilege All 1 Input format show telnet_port 2 Option None 3 Usage example show telnet_port Telnet Port Number 23 4 Message None ...

Page 454: ...TTP Port Number HTTPS status HTTPS Port Number Telnet status Telnet Port Number SSH status SSH Port Number Privilege All 1 Input format show telnet_port 2 Option None 3 Usage example show network Hostname hogehoge fujitsu com IP Address 10 1 2 124 Netmask 255 255 255 0 Gateway Address 10 1 2 1 IPv6 IP Address Prefix 2000 2002 2003 2004 2005 2006 2007 2008 64 IPv6 Gateway Address fe80 1234 f3ff fe0...

Page 455: ...g conditions of ntp Remarks Support of IPv4 IPv6 Privilege All 1 Input format show ntpq 2 Option None 3 Usage example show ntpq remote refid st t when poll reach delay offset jitter 10 23 4 3 10 0 50 32 4 u 882 1024 377 0 941 0 154 0 284 10 49 51 3 INIT 16 u 1024 0 0 000 0 000 0 000 LOCAL 0 LOCL 5 l 23h 64 0 0 000 0 000 0 000 ...

Page 456: ...1 Local server Acquisition of internal clock of MMB This type is considered only when remote is LOCAL u Unicast server Executes time request for the remote from MMB and acquires the transmitted time when Elapsed time from the time when packet is received for the last time from remote Unit seconds poll Interval to acquire time from remote Unit seconds reach Flag of failure and success of time acqui...

Page 457: ... is displayed when the user logs in from the serial port Displays whether the user is connected to the Telnet SSH or to the Web UI or whether connected to the serial port Remarks Support of IPv4 IPv6 Privilege All 1 Input format who 2 Option None 3 Usage example who Suzuki 2012 11 08 10 35 51 Telnet SSH 10 24 6 94 takahashi 2012 11 08 10 38 02 Telnet SSH 2001 2345 3dfb dc43 4d75 5a71 tanaka 2012 1...

Page 458: ...ds for Display 457 CA92344 0539 04 2 3 31 help Displays the help of enabled command Privilege All 1 Input format help 2 Option None 3 Usage example Omission Help of the command that can be used by each authority of the account is displayed 4 Message None ...

Page 459: ...0 byte packets 1 10 2 4 1 10 2 4 1 0 822 ms 5 142 ms 0 59 ms 2 10 2 5 1 10 2 5 1 0 923 ms 0 747 ms 0 679 ms 3 10 2 6 1 10 2 6 1 0 955 ms 0 736 ms 0 71 ms 4 10 3 2 1 10 3 2 1 1 023 ms 0 861 ms 0 837 ms 5 10 3 2 2 10 3 2 2 1 049 ms 0 939 ms 0 887 ms 6 10 2 3 5 10 2 3 5 1 285 ms 1 005 ms 0 997 ms 7 10 2 3 4 10 2 3 4 0 976 ms 0 828 ms 0 891 ms 4 Message The following table lists the messages which are...

Page 460: ...ormat netck arptbl 2 Option None 3 Usage example netck arptbl IP address HW type Flags HW address Mask Device 10 1 2 3 0x1 0x2 00 21 A1 1A 32 45 bond0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified parameter is invalid 5 Process Displays only bond 0 of cat proc ...

Page 461: ...tck arping ip 2 Option None 3 Usage example netck arping 10 1 2 3 ARPING to 10 1 2 3 from 10 1 2 33 via bond0 Unicast reply from 10 1 2 3 0 21 a1 1a 32 45 1 253ms Sent 1 probes 1 broadcast s Received 1 reply 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified paramet...

Page 462: ...0 inet6 addr 2001 2345 10 64 Scope Global inet6 addr fe80 217 42ff fe9b d978 64 Scope Link UP BROADCAST RUNNING MASTER MULTICAST MTU 1500 Metric 1 RX packets 4765 errors 0 dropped 0 overruns 0 frame 0 TX packets 3438 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 0 RX bytes 637685 622 7 KiB TX bytes 1318710 1 2 MiB 4 Message The following table lists the messages which are display...

Page 463: ...example netck stat Active Internet connections w o servers Proto Recv Q Send Q Local Address Foreign Address State tcp 0 0 PRIME123063 telnet 10 1 2 3 4015 TIME_WAIT 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified parameter is invalid 5 Process Clears the interna...

Page 464: ... details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Adding SB d to Partition d completed Adding IOU d to Partition d completed Removing SB d from Partition d completed Removing IOU d from Partition d completed not executed The specified partition number is invalid The specified parameter is invalid Unable to execute this command on a standby MMB Failed to show dy...

Page 465: ...rtitioning_mode partition 2 Option None 3 Usage example Example When Extended Partitioning mode of Partition 1 is displayed show partition extended_partitioning_mode 1 Partition 1 Extended Partitioning Mode enable 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified p...

Page 466: ...mat show partition dimm_excl_mode partition 2 Option None 3 Usage example Example When DIMM exclusive binding mode of Partition 4 is displayed show partition dimm_excl_mode 4 Partition 4 DIMM excl mode enable 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partit...

Page 467: ...how partition skt_binding_mode partition 2 Option None 3 Usage example Example When CPU socket binding mode of Partition 4 is displayed show partition skt_binding_mode 4 Partition 4 CPU Socket binding mode enable 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified pa...

Page 468: ...re number USB1 VGA USB2 DU On board GbE and PCI Express slot which are included in targeted partition DU and On board GbE displays in the ascending order of IOU PCI Express slot displays in the order of SB IOU and PCI_Box Privilege All 1 Input format show extended_partition configuration all free partition partition 2 Option all Displays all the partitions and the resources of the SB IOU PCI_Box w...

Page 469: ... 4 5 Web front 2 6CPU 1024GB VGA USB2 DU IOU 1 PCISLOT IOU 1 3 PCIBOX 0 0 3 6 Blank display since nothing is registered 7 Blank display since nothing is registered 8 Blank display since nothing is registered 9 Blank display since nothing is registered 10 Blank display since nothing is registered 11 Blank display since nothing is registered 4 Message The following table lists the messages which are...

Page 470: ...itioning Mode is disable Parents Physical Partition numbers are displayed for Extended Partitioning Third line Partition Name Fourth line Power Status of partition On Standby Fifth line onwards System Progress of partition Power Off Power On In Progress Reset EFI Boot OS Running OS Shutdown Panic Power Off In Progress Fatal Dumping Halt Extended Partitioning Running Privilege All 1 Input format sh...

Page 471: ...pecified parameter is invalid Unable to execute this command on a standby MMB Failed to execute show partition status command 2 3 43 show partition extended_socket_mode Displays the settings enable disable of of Extended Socket mode of specified Extended Partitioning Privilege All 1 Input format show partition extended_socket_mode Extended Partitioning 2 Option None 3 Usage example Example When yo...

Page 472: ...All 1 Input format show partition extended_socket_zone 2 Option None 3 Usage example Example Extended Socket Zone is displayed show partition extended_socket_zone 4 0 Standby enable 0 5 0 On enable 0 6 0 On disable none 7 0 Standby disable none 8 2 On disable none 9 2 On enable 1 10 3 On enable 3 11 3 On enable 3 4 Message The following table lists the messages which are displayed in this CLI For ...

Page 473: ...ion 2 Option None 3 Usage example Example When you display Rank of Memory Sparing Mode of Partitioning 3 show partition memory_sparing_mode 3 current 1 setting 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid The specified parameter i...

Page 474: ...41232964 23 9 0 0029 DU 0 0 FTS RAID Ctrl SAS 6G 1GB D3116C 0000000041432879 23 9 0 0029 DU 0 1 FTS RAID Ctrl SAS 6G 1GB D3116C 0000000041433203 23 9 0 0029 IOU 2 3 LSI MegaRAID SAS 9286CV 8e SV225P2246 23 9 0 0029 PCIBox 1 8 LSI MegaRAID SAS 9286CV 8e SV225P2374 23 9 0 0029 Example When you display the RAID adapter on SB 0 show raid adapter SB 0 0 Product Name FTS RAID Ctrl SAS 6G 1GB D3116C Seri...

Page 475: ...MMB CLI Command Line Interface Operations 2 3 Commands for Display 474 CA92344 0539 04 The operation is failed s Unable to execute the command because the s is under maintenance ...

Page 476: ...X40 0302 1 1 FUJITSU JX40 0302 Example When you display the disk enclosure attached to port 0 cascade 0 of RAID adapter on IOP 2 PCI slot 3 show raid disk_enclosure IOU 2 3 encl 0 0 Product Name FUJITSU ETERNUS JX40 Status OK Vendor FUJITSU Product JX40 Port number 0 Cascade 1 DeviceID 48 SAS address 51463080001ABC3E Firmware version 0302 4 Message The following table lists the messages which are ...

Page 477: ...apacity Action in progress 0 Operational SAS HDD FUJITSU MBD2300RC 300 GB 1 Operational SAS HDD FUJITSU MBD2300RC 300 GB 3 Available SAS SSD SEAGATE ST9146802SS 146 GB Example When you display the disk on slot 1 on SB 0 show raid physical_drive SB 0 0 disk 1 Slot 1 Status Operational Foreign configuration No Interface type SAS Interface type SAS Link speed 6 0Gb s Max device speed 6 0Gb s Type HDD...

Page 478: ...ascade 2 Option encl This option specifies port cascade and slot number for the target disk enclosure ex encl 0 0 3 Usage example Example When you display disk count attached to the RAID adapter on SB 0 show raid physical_drive_count SB 0 0 3 Example When you display disk count in the disk enclosure port 0 cascade 0 attached to the RAID adapter on IOU 0 PCI slot 1 show raid physical_drive_count IO...

Page 479: ...WS2012R2 278 00 GB RAID 1 Back ground initialization Example When you display the logical drive 1 on SB 0 show raid logical_drive SB 0 0 target 1 Target ID 1 Status Operational Name WS2012R2 RAID level RAID 1 Strip size 64K Logical size 278 00 GB Read mode Read ahead Write mode Write back Cache mode Direct Disk cache mode Disabled Background initialization Enabled Action in progress Back ground in...

Page 480: ...I_BOX UNIT PCISLOT 2 Option None 3 Usage example Example When you display logical drive count attached to the RAID adapter on SB 0 show raid logical_drive_count SB 0 0 2 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Too much arguments argc d Too few arguments argc d The spec...

Page 481: ...arent Next learn time Thu 17 Jul 2014 01 09 23 PM Auto learn period 28 Days Design voltage 9 411 V Voltage 9 518 V Temperature 27 deg C Design capacity 283 J Remaining capacity 321 J Capacitance 100 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 No logical drive is assigned t...

Page 482: ...Line Interface Operations 2 4 Update Command 481 CA92344 0539 04 2 4 Update Command Update Commands are as follows 2 4 1 Update ALL 2 4 2 show update_status This section describes operation procedure of these commands ...

Page 483: ...e show update_status command Note If the MMB or SB is faulty perform maintenance on it before updating the firmware Do not update the firmware in a configuration with a faulty MMB or SB Privilege Administrator or CE 1 Input format update ALL url force quiet 2 Option force This option forcibly updates the firmware based on the applicable general firmware version quiet This option updates the firmwa...

Page 484: ...formation could not be retrieved The chassis information is invalid 5 Process MMB checks whether the firmware update of online is executable When it is not possible to execute it the error message is output and the update processing is interrupted The condition that firmware update of online becomes improper MMB is an unredundant configuration There is no combination in the interchangeability tabl...

Page 485: ...strator or CE 1 Input format show update_status 2 Option None 3 Usage example show update_status Unified Firmware Version BA13012 update status updating 35 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Unified Firmware Version XX update status completed Unified Firmware Vers...

Page 486: ...and changes the password of the specified user Users without Administrator privileges can change only their own passwords Users with Administrator privileges can change the password of any user If no user is specified the command changes the password of the currently logged in user For details on characters that can be entered and other conditions see TABLE 1 87 Display Items and Setting Items in ...

Page 487: ...ord authentication New password differs from Re enter new password 2 5 3 ping The ping command sends an ICMP echo message to the recipient identified by IP address or server name Remarks Supported only for IPv4 Privilege All 1 Input format ping c count IP address server name 2 Option c count This option ends the command after sending a certain number count of packets The default is 1 3 Usage examp...

Page 488: ...scribes the functions of the PRIMEQUEST 2800B2 2800B model CLI commands Follow Chapter 2 5 from Chapter 2 2 about the part not described in this chapter The following tables list the account privileges required for individual commands Permitted in an account privilege column indicates the command can be used with those account privileges TABLE 2 9 MMB CLI commands Administrator TABLE 2 10 MMB CLI ...

Page 489: ...MMB CLI Command Line Interface Operations 2 6 PRIMEQUEST 2800B2 2800B model Commands 488 CA92344 0539 04 TABLE 2 11 MMB CLI commands User ...

Page 490: ...ted Displays Memory operation at Mode set pci_address_mode Sets PCI bus number allocation mod show pci_address_mode Displays PCI bus number allocation mod set lan_device_mode Permitted Sets LAN device mode show lan_device_mode Permitted Displays LAN device mode set pci_express_mode Sets PCI express mode show pci_express_mode Displays PCI express mode set partition name Sets the partition name show...

Page 491: ...aid locate_ld Permitted Stop locate disk LEDs for logical drive start raid locate_encl Permitted Start locate disk enclosure LED stop raid locate_encl Permitted Stop locate disk enclosure LED start raid rebuild Permitted Start disk rebuilding cancel raid rebuild Permitted Cancel disk rebuilding start raid copyback Permitted Start disk copyback cancel raid copyback Permitted Stop disk copyback star...

Page 492: ...ress_mode Sets PCI bus number allocation mod show pci_address_mode Displays PCI bus number allocation mod set lan_device_mode Permitted Sets LAN device mode show lan_device_mode Permitted Displays LAN device mode set pci_express_mode Sets PCI express mode show pci_express_mode Displays PCI express mode set partition name Sets the partition name show partition name Displays the partition name hotad...

Page 493: ...for logical drive start raid locate_encl Permitted Start locate disk enclosure LED stop raid locate_encl Permitted Stop locate disk enclosure LED start raid rebuild Permitted Start disk rebuilding cancel raid rebuild Permitted Cancel disk rebuilding start raid copyback Permitted Start disk copyback cancel raid copyback Permitted Stop disk copyback start raid mdc Permitted Start make data consisten...

Page 494: ...dress_mode Sets PCI bus number allocation mod show pci_address_mode Displays PCI bus number allocation mod set lan_device_mode Sets LAN device mode show lan_device_mode Permitted Displays LAN device mode set pci_express_mode Sets PCI express mode show pci_express_mode Displays PCI express mode set partition name Sets the partition name show partition name Displays the partition name hotadd partiti...

Page 495: ...sk LEDs for logical drive start raid locate_encl Start locate disk enclosure LED stop raid locate_encl Stop locate disk enclosure LED start raid rebuild Start disk rebuilding cancel raid rebuild Cancel disk rebuilding start raid copyback Start disk copyback cancel raid copyback Stop disk copyback start raid mdc Start make data consistency MDC cancel raid mdc Cancel MDC start raid patrol Start RAID...

Page 496: ...ess_mode Sets PCI bus number allocation mod show pci_address_mode Displays PCI bus number allocation mod set lan_device_mode Sets LAN device mode show lan_device_mode Permitted Displays LAN device mode set pci_express_mode Sets PCI express mode show pci_express_mode Displays PCI express mode set partition name Sets the partition name show partition name Displays the partition name hotadd partition...

Page 497: ...k LEDs for logical drive start raid locate_encl Start locate disk enclosure LED stop raid locate_encl Stop locate disk enclosure LED start raid rebuild Start disk rebuilding cancel raid rebuild Cancel disk rebuilding start raid copyback Start disk copyback cancel raid copyback Stop disk copyback start raid mdc Start make data consistency MDC cancel raid mdc Cancel MDC start raid patrol Start RAID ...

Page 498: ...off forcefully without shutting down the operating system of system 3 Usage example None 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified parameter is invalid Unable to power off the system Unable to force power off on the system Command Failed Code 0x 04X 0x 02X ...

Page 499: ...The specified parameter is invalid Unable to power on the partition d due to CPU mismatch between SBs Unable to power on the partition d due to DIMM does not satisfy requirements of Mode Unable to power on due to mismatch between supply voltage and input voltage Unable to power on the partition d due to abnormal DIMM composition Unable to power on the partition d due to abnormal SB composition Una...

Page 500: ...le When reset is directed by the Administrator authority Administrator reset Are you sure you want to Reset Y N Y Administrator 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure you want to Reset to system Y N The specified parameter is invalid Unable to Reset the s...

Page 501: ... the user 3 Usage example Example When NMI is directed by the Administrator authority Administrator nmi Are you sure you want to NMI Y N Y Administrator 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Are you sure you want to NMI to System Y N The specified parameter is invali...

Page 502: ...ommand is executed without interactive operation to User 3 Usage example Example When setting Memory Operation Mode of the system to performance set memory_operation_mode performance The setting will become effective the next time the system power off on is performed 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000...

Page 503: ...uted without interactive operation to User 3 Usage example Example When setting Memory Mirror RAS Mode of the system to Mirror Keep Mode set memory_mirror_ras_mode mirror_keep The setting will become effective the next time the system power off on is performed 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series...

Page 504: ...reover also when values which are the same as the current values are set power off on is not required and the above mentioned message is not displayed Privilege Administrator Operator 1 Input format set lan_device_mode IOU wol_enable wol_disable device_disable quiet 2 Option quiet The command is executed without interactive operation to User 3 Usage example Example When setting IOU 2 to Enable WOL...

Page 505: ...ows Spare Mode Privilege All 1 Input format show memory_operation_mode 2 Option None 3 Usage example Example When Memory Operation Mode of system is displayed show memory_operation_mode current normal setting performance 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The spec...

Page 506: ...w memory_mirror_ras_mode 2 Option None 3 Usage example Example When Memory Mirror RAS Mode of system is displayed show memory_mirror_ras_mode current mirror_keep setting capacity_keep 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified parameter is invalid Failed to ...

Page 507: ...the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified parameter is invalid Failed to execute s command Failed to execute show lan_device_mode command System Configuration Failed 2 6 12 set mmbcontrol reset Specify the MMB reset This command execution is controlled at the time of the maintenance mode Privilege Administrator 1 Input format set mmbcontrol reset quie...

Page 508: ...haracters You can specify the following characters in a password 0 9 a z A Z and special characters _ confirm password Used to reenter a password for confirmation privilege Sets the privileges of the user account You can specify either admin operator user or ce Quiet The command is executed without interactive operation with the user 3 Usage example Example In case of admin authority add user Aaaa...

Page 509: ...displayed Privilege Administrator 1 Input format show user_list 2 Option None 3 Usage example show user_list user_name privilege Aaaaaaaa Admin Cccccccccc Operator Dddddddd CE 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified parameter is invalid ...

Page 510: ...to force disconnect current user Y N Privilege Administrator Operator CE 1 Input format console timeout quiet 2 Option timeout Sets timeout value Set by 0 or within the range of 1 120 minutes 0 consists of the special meaning it indicates no Timeout Default setting is 10 minutes Perform the operation by default value when this option is not specified quiet Executes the command without interactive ...

Page 511: ...er Off Power On In Progress Reset EFI Boot OS Running OS Shutdown Panic Power Off In Progress Fatal Dumping Halt Privilege All 1 Input format show system_control status 2 Option None 3 Usage example Example show system_control status Power Status On System Progress OS Running 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQ...

Page 512: ... it is unnecessary Privilege Administrator Operator 1 Input format set memory_sparing_mode 1 2 auto quiet 2 Option quiet The command is executed without interacting with the user 3 Usage example Example When you set Rank of Memory Sparing Mode to 1 set memory_sparing_mode 1 The setting will become effective the next time the system power off on is performed 4 Message The following table lists the ...

Page 513: ... Input format show memory_sparing_mode 2 Option None 3 Usage example Example When you display Rank of Memory Sparing Mode show memory_sparing_mode current 1 setting 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The specified partition number is invalid Failed to execute s ...

Page 514: ...2 64 128 256 512 or 1024 If this parameter is omitted 64 will be set ex stripe 1024 init This option specifies how you want to initialize the logical drive after the creation If this parameter is omitted no initialization will be done ex init fast force The command is executed without interactive operation with the user The mandatory options are disk and level and the other options are omitted The...

Page 515: ...ve cannot be changed from default value when the logical drive is created If you want to change these parameter you should use modify raid policy command after created the logical drive These policies are set default values in the table below Parameter Default value Selectable values Read Policy No Read Ahead No Read Ahead Read Ahead Write Policy Write Back Write Back Write Through Force Write Bac...

Page 516: ...roller on SB 0 delete raid logical_drive SB 0 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified control...

Page 517: ...Through To eliminate risk of losing cached data in case of power failure However it may result in slower performance Force Write Back The logical drive is in Write Back mode even if the battery is not present data loss may occur in the event of a power failure io This option number of IO policy from 0 Direct 1 Cached cache This option specifies number of drive cache policy from 0 Unchanged 1 Enabl...

Page 518: ...0 1 5 6 1E 10 50 or 60 ex level 5 force The command is executed without interactive operation with the user 3 Usage example Example When you modify RAID level of a logical drive to RAID 6 as RAID level migration RLM with additional disk attached to slot 3 modify raid logical_drive SB 0 0 target 0 disk 3 level 6 4 Message The following table lists the messages which are displayed in this CLI For de...

Page 519: ...ssign a global hotspare to a disk attached to slot 0 create raid global_hotspare SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parame...

Page 520: ...ted without interactive operation with the user 3 Usage example Example When you assign a dedicated hotspare for the logical drive 0 to a disk attached to slot 0 create raid dedicated_hotspare SB 0 0 disk 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command i...

Page 521: ...n you delete a hotspare to a disk attached to slot 0 delete raid hotspare SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is ...

Page 522: ...ed to slot 0 start raid locate_pd SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade n...

Page 523: ...hed to slot 0 stop raid locate_pd SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade n...

Page 524: ...a disk assigned to the logical drive 1 start raid locate_ld SB 0 0 target 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is ...

Page 525: ...a disk assigned to the logical drive 1 stop raid locate_ld SB 0 0 target 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is n...

Page 526: ...d locate_pd SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade number is required in t...

Page 527: ... locate_pd SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Port and cascade number is required in th...

Page 528: ...ding a disk attached to slot 0 start raid rebuild SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified ...

Page 529: ...lding a disk attached to slot 0 cancel raid rebuild SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specifie...

Page 530: ... e g dist 0 0 0 force The command is executed without interactive operation with the user 3 Usage example Example When you start coyback from a disk attached to slot 0 to a disk attached to slot 1 start raid copyback SB 0 0 src 0 dist 1 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA923...

Page 531: ...back to a disk attached to slot 0 cancel raid copyback SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The speci...

Page 532: ...ical drive 0 start raid mdc SB 0 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not fo...

Page 533: ...gical drive 0 start raid mdc SB 0 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not f...

Page 534: ... Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Internal error d d The operation is faile...

Page 535: ... 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controller is not found Internal error d d The operation is fai...

Page 536: ... disk attached to slot 0 make raid online SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified controll...

Page 537: ...a disk attached to slot 0 make raid offline SB 0 0 disk 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is canceled Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified contro...

Page 538: ...the user 3 Usage example Example When you replace a disk attached to slot 0 to the logical drive 0 which has missing drive replace raid missing_drive SB 0 0 disk 0 target 0 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 The command is executed successfully The operation is ca...

Page 539: ... 0000000041232964 23 9 0 0029 DU 0 0 FTS RAID Ctrl SAS 6G 1GB D3116C 0000000041432879 23 9 0 0029 DU 0 1 FTS RAID Ctrl SAS 6G 1GB D3116C 0000000041433203 23 9 0 0029 IOU 2 3 LSI MegaRAID SAS 9286CV 8e SV225P2246 23 9 0 0029 PCIBox 1 8 LSI MegaRAID SAS 9286CV 8e SV225P2374 23 9 0 0029 Example When you display the RAID adapter on SB 0 show raid adapter SB 0 0 Product Name FTS RAID Ctrl SAS 6G 1GB D3...

Page 540: ...MMB CLI Command Line Interface Operations 2 6 PRIMEQUEST 2800B2 2800B model Commands 539 CA92344 0539 04 The operation is failed s Unable to execute the command because the s is under maintenance ...

Page 541: ...FUJITSU JX40 0302 1 1 FUJITSU JX40 0302 Example When you display the disk enclosure attached to port 0 cascade 0 of RAID adapter on IOP 2 PCI slot 3 show raid disk_enclosure IOU 2 3 encl 0 0 Product Name FUJITSU ETERNUS JX40 Status OK Vendor FUJITSU Product JX40 Port number 0 Cascade 1 DeviceID 48 SAS address 51463080001ABC3E Firmware version 0302 4 Message The following table lists the messages w...

Page 542: ...Product Capacity Action in progress 0 Operational SAS HDD FUJITSU MBD2300RC 300 GB 1 Operational SAS HDD FUJITSU MBD2300RC 300 GB 3 Available SAS SSD SEAGATE ST9146802SS 146 GB Example When you display the disk on slot 1 on SB 0 show raid physical_drive SB 0 0 disk 1 Slot 1 Status Operational Foreign configuration No Interface type SAS Interface type SAS Link speed 6 0Gb s Max device speed 6 0Gb s...

Page 543: ...parameter is invalid s The specified controller is not found Port and cascade number is required in the parameter since more than 2 enclosures are connected Internal error d d Unable to execute the command because the system is under maintenance Unable to execute the command because the Partition d is under maintenance ...

Page 544: ...ount attached to the RAID adapter on SB 0 show raid physical_drive_count SB 0 0 3 Example When you display disk count in the disk enclosure port 0 cascade 0 attached to the RAID adapter on IOU 0 PCI slot 1 show raid physical_drive_count IOU 0 1 encl 0 0 24 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Mes...

Page 545: ...rational WS2012R2 278 00 GB RAID 1 Back ground initialization Example When you display the logical drive 1 on SB 0 show raid logical_drive SB 0 0 target 1 Target ID 1 Status Operational Name WS2012R2 RAID level RAID 1 Strip size 64K Logical size 278 00 GB Read mode Read ahead Write mode Write back Cache mode Direct Disk cache mode Disabled Background initialization Enabled Action in progress Back ...

Page 546: ...I Command Line Interface Operations 2 6 PRIMEQUEST 2800B2 2800B model Commands 545 CA92344 0539 04 Internal error d d The operation is failed s Unable to execute the command because the s is under maintenance ...

Page 547: ...le Example When you display logical drive count attached to the RAID adapter on SB 0 show raid logical_drive_count SB 0 0 2 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 Too much arguments argc d Too few arguments argc d The specified parameter is invalid s The specified con...

Page 548: ...de Transparent Next learn time Thu 17 Jul 2014 01 09 23 PM Auto learn period 28 Days Design voltage 9 411 V Voltage 9 518 V Temperature 27 deg C Design capacity 283 J Remaining capacity 321 J Capacitance 100 4 Message The following table lists the messages which are displayed in this CLI For details of the messages see the PRIMEQUEST 2000 Series Message Reference CA92344 0540 No logical drive is a...

Page 549: ... relevant menu from the front page of Boot Manager For details on sadump Configuration see Chapter 6 Setting up the sadump Environment 3 1 Front page of Boot Manager The Front page of Boot Manager is the top page of UEFI In this window you can move to Boot processing or can move to Boot Manager Device Manager and Boot Maintenance Manager by using a relevant menu FIGURE 3 1 Display Example of Front...

Page 550: ...splays 3 3 Boot Manager Menu Device Manager Displays 3 4 Device Manager Menu Boot Maintenance Manager Displays 3 5 Boot maintenance Manager Menu BIOS Boot Diagnotstic Test Executes BIOS Boot Diagnotstic Test After execution the power supply to the partition must be turned Off 2 Operation help display part The help for operations mentioned on this page is shown in the TABLE 3 2 Display Items on Ope...

Page 551: ...pes such as boot type for UEFI Aware operating system and boot type for legacy operating system The difference in these two types is given below Method of specifying the boot device As for the boot device specification of UEFI Aware Operating System the executable file can be specified up to the unit by the device path expression based on the UEFI specification On the contrary for the boot device ...

Page 552: ...r of Windows Server 2008 or later which is UEFI Aware operating system is installed In this example boot for Windows server 2008 or later of UEFI Aware operating system is tested initially FIGURE 3 4 Boot Option of Boot Manager If booting is successful the operating system is booted If the booting is failed the following boot option is booted In the example of FIGURE 3 4 Boot Option of Boot Manage...

Page 553: ...ows Boot Manager and the boot of Windows is not executed automatically Specifically set according to the following procedures 1 Decide the boot priority level by the Change Boot Order window of the Boot Options menu See Change Boot Order menu 2 Set startup priority level of multiple Floppy in the Set Legacy Floppy Drive Order menu of the Boot Options menu See Set Legacy Floppy Drive Order menu 3 S...

Page 554: ...ority level is lower than the legacy boot option is not booted automatically 4 Fujitsu Virtual CDROMO 1 00 Tries legacy operating system boot from CD ROM of legacy 5 EFI USB Device 2 Priority is lower than the Legacy Boot Option thus unable to boot automatically 6 Fujitsu Virtual Floppy0 1 00 Tries legacy operating system boot from Floppy drive of the legacy 7 EFI Internal Shell Starts UEFI Shell ...

Page 555: ...acy Floppy TABLE 3 7 If boot of Windows Boot Manager EFI Network Device and EFI USB Device fails or if booted from Legacy Floppy UEFI Boot specifications Flow of start up 1 Windows Boot Manager Tries the boot of Windows Boot Manager Boot Failure 2 EFI USB Device Boot Failure 3 EFI Network Device Boot Failure 4 Fujitsu Virtual CDROM0 1 00 Tries the Legacy operating system Boot from high priority Se...

Page 556: ...ting system Such as Windows Boot Manager the targeted device cannot be recognized In boot process of UEFI Aware operating system Such as Windows Boot Manager UEFI partition was not exist in targeted device In boot of UEFI Embedded DVD CD UEFI DVD CD n media was not found in the corresponding DVD CD device In boot of UEFI Embedded DVD CD UEFI DVD CD n media which is mounted on the corresponding DVD...

Page 557: ...stem which is booted with key or with key or the cursor is set to UEFI Shell and the selection is done If Enter key is pressed the selected UEFI Aware operating system or legacy operating system tries a boot and UEFI shell tries a startup If booting fails returns to the Boot Manager front page 3 Operation help display The help for operations mentioned on this page is shown in the TABLE 3 9 Display...

Page 558: ...hown in TABLE 3 10 Displayed contents of menu selection is displayed TABLE 3 10 Displayed contents of menu selection Items Description System Information Displays 3 4 1 System Information Menu LAN Remote Boot Configuration Displays 3 4 2 LAN Remote Boot Configuration Menu CPU Configuration Displays 3 4 3 CPU Configuration Menu 1 PCI Subsystem Configuration Displays 3 4 4 PCI Subsystem Configuratio...

Page 559: ...n in the TABLE 3 11 Displayed contents of operation help display is displayed TABLE 3 11 Displayed contents of operation help display Items Description Move Highlight Moves the cursor up and down Enter Select Entry Selects the item Esc Exit Returns to 3 1 Front page of Boot Manager 3 4 1 System Information Menu The information on the system is displayed in the System Information menu There is no i...

Page 560: ...rocessor speed Display example 2700 MHz Cache Counts Sizes 1 Displays cache size Display example 8x8 KB 8x32 KB 1x 20 MB Active Package Core Thread Count maximum Displays the number of CPU packages numbers of cores and numbers of threads Display example 2 2 Package s 8 16 Core s 16 32 Thread s Memory Size Frequency Displays memory size and frequency Display example 32768 MB 1333 MHz 3 Help Operati...

Page 561: ...2 Boot options of PXE boot are added to Set Legacy NET Drive Order Menu Change in order of priority Set Legacy NET Drive Order of 3 5 2 Boot Options menu of Boot Maintenance Manager Menu This item is not displayed for the network port of the PCI LAN card Legacy iSCSI 3 Press Ctrl D to run setup message is displayed at the time of boot When Ctrl D is pressed in accordance with that message setting ...

Page 562: ...formation is displayed by the MAC address format for onboard LAN and displayed by the slot number for the PCI LAN card Commit Changes and Exit After saving the contents the setting of which are changed exit from this menu Discard Changes and Exit After cancelling the contents the setting of which are changed exit from this menu 3 Display of Operation help Description of operation key shown in TABL...

Page 563: ...ing System is set to Enable UEFI PXE iSCSI is selected When PXE boot of Legacy Operation System is set to Enable Legacy PXE is selected When iSCSI boot of Legacy Operation System is set to Enable Legacy iSCSI is selected When PXE iSCSI boot is set to Disable Disabled is selected By default all are Disabled 3 Press Enter key 4 To exit from this menu after saving the changes in the settings select C...

Page 564: ...k ports are added as in FIGURE 3 12 Display of MAC Selection FIGURE 3 12 Display of MAC Selection 7 When Legacy PXE is set to Enable if Set Legacy NET Drive Order Menu of Boot Maintenance Manager Menu is activated after reset network ports are added as in FIGURE 3 13 Display of Set Legacy Net Drive Order Menu See Set Legacy Net Drive Order Menu Check to be added this item in the last line Check to...

Page 565: ...UEFI Menu Operations 3 4 Device Manager Menu 564 CA92344 0539 04 FIGURE 3 13 Display of Set Legacy Net Drive Order Menu Check to be added one network port ...

Page 566: ... Menu Following is the display of window immediately after start up of CPU Configuration Menu FIGURE 3 14 Display Example of CPU Configuration Menu FIGURE 3 15 Display Example of CPU Configuration Menu PRIMEQUEST 2400E2 2800E2 2800B2 1 Page Information Display CPU Configuration is displayed 2 Menu Selection The items shown in the TABLE 3 17 Display Contents of Menu Selection are displayed on the M...

Page 567: ...EST 2400E 2800E 2800B The number that can be selected according to the number of cores of mounted CPU changes All and 1 14 can be selected for 15 cores CPU Default setting is All Only for PRIMEQUEST 2400E2 2800E2 2800B2 Current Available Number XX of effective processor cores now and all mounted numbers YY of cores are displayed XX YY Hardware Prefetcher Sets the Hardware Prefetcher function to en...

Page 568: ... in Power Technology Turbo Mode 1 Sets the Intel R Turbo Boost Technology function to enable or disable Enabled Disabled Default setting is Enabled Remarks Displays only when Custom is selected in Power Technology Energy Performance 1 Selects the Energy Performance mode Performance Balanced Performance Balanced Energy Energy Efficient Default setting is Performance Remarks Displays only when Custo...

Page 569: ...Floor Override 1 Sets the Frequency Floor Override function to enable or disable Enabled Disabled Default setting is Disabled Only for PRIMEQUEST 2400E2 2800E2 2800B2 Uncore Frequency Scaling 1 Sets the Uncore Frequency Scaling to enable or disable Enabled Disabled Default setting is Enabled Perfmon and DFX devices 1 Sets the Perfmon and DFX devices function to enable or disable Enabled Disabled D...

Page 570: ... to succeed a part of setting of a physical partition in the enhancing partition All items set by the CPU Configuration menu are succeeded when changing into Reserved SB 3 Operation Help Display Description of Operating Keys is shown in the TABLE 3 18 Display Contents of Operation Help Display TABLE 3 18 Display Contents of Operation Help Display Item Description Move Highlight Moves cursor up and...

Page 571: ...guration menu The example of contents displayed on screen immediately after the activation of PCI Subsystem Configuration Menu is given below FIGURE 3 16 Display Example on PCI Subsystem Configuration Menu 1 Page Information Display PCI Subsystem Configuration is displayed 2 Menu Selection The items shown in TABLE 3 19 Display Contents of Menu Selection are displayed ...

Page 572: ...t 1 2 3 Default setting is 1 Above 4G decoding Sets enable disable of 4G or more Memory Mapped I O Disabled Enabled Default setting is Disabled OpROM MMIO Assignment Sets whether to allocate OpROM in MMIO Disabled Enabled Default setting is Enabled OpROM Scan Configuration Opens OpROM Scan Configuration Menu I O Space Assignment Configuration Opens I O Space Assignment Configuration Menu Commit Ch...

Page 573: ...ounted on each IOU and each PCI_Box is configured on OpROM Scan Configuration Menu Window display example of OpROM Scan Configuration Menu shows in the following figure FIGURE 3 17 Display Example of OpROM Scan Configuration Menu 1 Page Information Display OpROM Scan Configuration is displayed 2 Menu Selection Menu is shown in the ...

Page 574: ... 2 OpROM Sets enable disable of Legacy OpROM of mounted PCI cards Enabled Disabled Default setting is Disabled Settings for PCI Express slot 2 of IOU 0 Slot 3 OpROM Sets enable disable of Legacy OpROM of mounted PCI cards Enabled Disabled Default setting is Disabled Settings for PCI Express slot 3 of IOU 0 IOU 1 Slot of IOU 1 Only the display DUSlot 1 OpROM Sets enable disable of Legacy OpROM of m...

Page 575: ...OM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 2 of IOU 2 Slot 3 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 3 of IOU 2 IOU 3 Slot of IOU 3 Only the display DUSlot 1 OpROM Enables disables Legacy OpROM of the PCI...

Page 576: ...Box 0 Slot 3 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 3 of PCI_Box 0 Slot 4 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 4 of PCI_Box 0 Slot 5 OpROM Enables disables Legacy OpROM of the PCI card which is ...

Page 577: ...PCI_Box 1 Slot 1 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 1 of PCI_Box 1 Slot 2 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 2 of PCI_Box 1 Slot 3 OpROM Enables disables Legacy OpROM of the PCI card which...

Page 578: ... OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 11 of PCI_Box 1 PCI Box 2 Slot of PCI Box 2 Only the display Slot 0 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 0 of PCI_Box 2 Slot 1 OpROM Enables disables Legacy OpROM of the PCI card which...

Page 579: ...ROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 9 of PCI_Box 2 Slot 10 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 10 of PCI_Box 2 Slot 11 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is ...

Page 580: ...isabled Setting for PCI Express slot 7 of PCI_Box 3 Slot 8 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 8 of PCI_Box 3 Slot 9 OpROM Enables disables Legacy OpROM of the PCI card which is mounted Enabled Disabled By default it is Disabled Setting for PCI Express slot 9 of PCI_Box 3 Slot 10 OpROM Enables ...

Page 581: ...ons mentioned on this page is shown in TABLE 3 22 Display contents of operation help display Items Description Move Highlight Moves the cursor up and down Enter Select Entry Selects the items Esc Exit Returns to 3 1 Front page of Boot Manager without saving the setting changes of this menu ...

Page 582: ...llocated either To allocate the I O space as follows is surely done Force is set to the device that wants to allocate the I O space After resetting the system for which I O space is assigned in this menu open this menu once again and confirm that the I O space is assigned for the relevant system The settings changed in this menu are enabled after the system is reset Following is the display of win...

Page 583: ...hich Auto is set However an error message is displayed if no of slots which can be assigned exceeds and is set to Force Auto I O space is assigned to the extent that there is no shortage of I O space Disabled I O space is not assigned Default setting is Auto Commit Changes and Exit After saving the contents the setting of which are changed exit from this menu Discard Changes and Exit After cancell...

Page 584: ...he environment of iSCSI boot of UEFI Aware Operating System can be set The iSCSI boot capable network port is displayed in the menu The network port which boots the iSCSI is selected and with various settings iSCSI can be booted from the intended device The settings which are changed in the menu will become valid after system reset The display example of iSCSI Configuration menu is as follows FIGU...

Page 585: ... ports for which iSCSI is valid is displayed Delete Attempt Opens Delete Attempt menu Change Attempt Order Opens Change Attempt Order menu 3 Operation help display Description of operation key shown in TABLE 3 26 Display contents of Operation Help Display is displayed TABLE 3 26 Display contents of Operation Help Display Items Description Move Highlight Moves the cursor in up and down direction En...

Page 586: ...cters which are entered are not enough Pop Up window of Please enter enough characters Press ENTER to continue is displayed Types of characters which can be entered here are as follows 0 9 A Z a z _ 2 Attempt is created Place the cursor on Add an Attempt of iSCSI Configuration menu and then press Enter key 3 Displayed as per FIGURE 3 21 iSCSI Environment Setting Operation Windows 2 MAC Selection m...

Page 587: ...ation Windows 2 MAC Selection menu Place the cursor on network port in which iSCSI booting is done and then press Enter key 4 Displayed as per FIGURE 3 22 iSCSI Environment Setting Operation Windows 3 Attempt Configuration menu For details of Attempt Configuration menu see 3 4 9 2 Attempt Configuration Menu ...

Page 588: ... Windows 3 Attempt Configuration menu Place the cursor position on the item which is to be set and then set each 5 To exit from this menu after saving the changes select Save Changes and then press Enter key 6 To exit from this menu without saving the changes select Back to Previous Page and then press Enter key ...

Page 589: ... menu shown in TABLE 3 27 Display contents of menu selection is displayed TABLE 3 27 Display contents of menu selection Item Display content MAC xx xx xx xx xx xx Displays menu Remarks xx xx xx xx xx xx is MAC address iSCSI configurable device is displayed in MAC address format Commit Changes and Exit Saves the content having the setting changes and exit from this menu Discard Changes and Exit Can...

Page 590: ...e Manager Menu 589 CA92344 0539 04 TABLE 3 28 Display contents of operation help display Item Description Move Highlight Moves cursor up and down Enter Select Entry Selects the item Esc Exit Returns to 3 4 9 iSCSI Configuration menu ...

Page 591: ...ious settings related to iSCSI Boot can be done in Attempt Configuration menu The settings which were changed in this menu are enabled after system reset The example of window displayed immediately after starting the Attempt Configuration menu is shown below FIGURE 3 24 Display example of Attempt Configuration Menu 1 Page information display It is displayed as Attempt Configuration 2 Menu selectio...

Page 592: ... Default setting is generated by MAC address Remarks When the characters entered are insufficient a pop up window showing the message Please enter enough characters Press ENTER to continue appears If more than 7 digits are entered in ISDI a pop up window showing the message Error Input is incorrect please input 6 hex numbers appears If 6 digits contain the value other than the hexadecimal number t...

Page 593: ...ternet Protocol is set to IP4 or IP6 and disabled Get Target info via DHCP By default it is 0 0 0 0 Remarks If incorrect value is entered in IP address subnet mask then pop up window of Invalid IP Address is displayed Target Port Sets TCP listening port of target Numeric value which can be entered is in the range of 0 65535 decimal This item is displayed when Internet Protocol is set to IP4 or IP6...

Page 594: ...AP password When CHAP Type is set to One way this item is not displayed also when Authentication Type is set to None this item is not displayed Number of characters that can be entered is in the range of 12 16 Remarks If number of characters are not enough then pop up window of Please enter enough characters Press ENTER to continue is displayed Types of characters that can be entered are given bel...

Page 595: ...isplayed TABLE 3 31 Display contents of Menu selection Item Display contents Attempt xxxx xxxx displays the name set in iSCSI Attempt Name of 3 4 9 2 Attempt Configuration Menu X appears when space key is pressed If Commit Changes and Exit is selected in this state iSCSI settings get cancelled X If Commit Changes and Exit is selected at this state iSCSI settings get cancelled Commit Changes and Ex...

Page 596: ...e Manager Menu 595 CA92344 0539 04 TABLE 3 32 Display Contents of Operation Help Display Item Description Move Highlight Moves the cursor up and down Enter Select Entry Selects item Esc Exit Returns to 3 4 9 iSCSI Configuration menu ...

Page 597: ...menu is shown in TABLE 3 33 Display contents of Menu selection TABLE 3 33 Display contents of Menu selection Item Display contents Change Attempt Order Priority level can be raised with Key after selecting Attempt xxxx xxxx displays the name set in iSCSI Attempt Name of 3 4 9 2 Attempt Configuration Menu Commit Changes and Exit Saves the changed contents and exits from this menu Discard Changes an...

Page 598: ...sc Exit Returns to 3 4 9 iSCSI Configuration menu Remarks TABLE 3 40 Display contents of operation help display and the contents displayed differ as FIGURE 3 26 Display example of Change Attempt Order Menu is the display example window after selecting Attempt Contents displayed in TABLE 3 34 Display Contents of Operation Help Display are displayed immediately after the activation of Change Attempt...

Page 599: ...ges in this menu are enabled after the system is reset FIGURE 3 27 Display Example of Memory Configuration Menu The following section shows the window display example of Memory Configuration menu 1 Page information display Displayed as Memory Configuration 2 Menu selection Items are shown in the TABLE 3 35 Display Contents of Menu Selection are shown in the menu ...

Page 600: ...x Default setting is Auto Memory Power States 1 Sets the Power State of the memory Default Perfomance Mode Default setting is Default Only for PRIMEQUEST 2400E2 2800E2 2800B2 DDR4 Command Address Parity Check and Retry 1 Sets the DDR4 Command Address Parity Check and Retry function to enable or disable Enabled Disabled Default setting is Enabled Commit Changes and Exit Saves the changed contents a...

Page 601: ...ed in Extended Partitioning where USB controller is not allocated The following figure shows the example of window which is displayed immediately after activation of USB Configuration menu FIGURE 3 28 Display example of USB Configuration menu 1 Page information display Displayed with USB Configuration 2 Menu selection Items shown in TABLE 3 37 Display contents of Menu selection are shown in the Me...

Page 602: ... name Sets the emulation pattern of device Auto Floppy Forced FDD Hard Disk CD ROM Default setting is Auto Remarks When Auto is selected it is emulated according to the media format of device Optical disk drive is emulated as CD ROM drive without media is emulated according to the drive type Commit Changes and Exit Saves the changed contents and exits from this menu Discard Changes and Exit Cancel...

Page 603: ...ity Configuration menu is not displayed Moreover if the TPM chip is not mounted Security Configuration menu is not displayed The following figure shows the window display example of Security Configuration menu FIGURE 3 29 Display Example of Security Configuration Menu 1 Page information display Displayed as Security Configuration menu 2 Menu selection Selection menu is shown in the TABLE 3 39 Disp...

Page 604: ...le if TPM Active Status is Activated In other situations gray out is displayed and selection is not possible Current Status Information Current status of TPM chip is displayed When TPM Support is set to Disabled SUPPORT TURNED OFF is displayed Warning Following is the TPM Chip status displayed as TPM Enabled Status TPM Activate Status and TPM Owner Status No item is set However as the TPM Chip sta...

Page 605: ...is shown in TABLE 3 40 Display contents of operation help display TABLE 3 40 Display contents of operation help display Items Description Move Highlight Moves the cursor up and down Enter Select Entry Selects the items Esc Exit Returns to 3 1 Front page of Boot Manager without saving the setting changes of this menu ...

Page 606: ...deleted the state becomes Disabled Attempt Secure Boot Sets the settings of Secure Boot Invalidity X Effective Secure Boot Mode Sets the settings of Secure Boot Mode Standard Key Management cannot be changed Custom Key Management can be changed When the menu can be pulled out the mode is changed to Standard Mode Custom Secure Boot Options Opens Custom Secure Boot Options Menu When Secure Boot Mode...

Page 607: ...d Attempt Secure Boot is changed to Disabled Platform Key of a system initial value is reregistered when rebooting a system with Platform Key deleted 3 4 9 3 Save PK file Menu In Save PK file Menu it is possible to register Platform Key TABLE 3 44 Display Contents of Save PK file Menu Items Description File name of PK Displays the file name of selected Platform Key Commit Changes and Exit Saves th...

Page 608: ... extension is not pbk though the file is RSA2048 form the error message is displayed Error Message ERROR Unsupported file type Discard Changes and Exit Cancels the file saving and exits from this menu 3 4 9 6 Delete KEK Menu In Delete KEK Menu it is possible to set it concerning Key Exchange Key TABLE 3 47 Display Contents of Delete KEK Menu Items Description Signature GUID of KEK Key Exchange Key...

Page 609: ...extension is not cer der crt the error message is displayed Error Message ERROR Unsupported file type Discard Changes and Exit Cancels the file saving and exits from this menu 3 4 9 9 Delete Signature Menu In Delete Signature Menu it is possible to set it concerning DB TABLE 3 50 Display Contents of Delete Signature Menu Items Description Signature GUID of DB DB is deleted when selecting it in spa...

Page 610: ...Exit Saves the file and exits from this menu When the file is not a certificate of the X509 standard and when the file extension is not cer der crt the error message is displayed Error Message ERROR Unsupported file type Discard Changes and Exit Cancels the file saving and exits from this menu 3 4 9 12 Delete Signature Menu In Delete Signature Menu it is possible to set it concerning DBX TABLE 3 5...

Page 611: ...e window immediately after the activation of Boot maintenance Manager menu FIGURE 3 30 Boot Maintenance manager Menu 1 Page Information Display Displays as Boot maintenance Manager 2 Menu selection Displays the menu as shown in TABLE 3 54 Display Contents of Menu Selection TABLE 3 54 Display Contents of Menu Selection Items Description Boot Mode Displays 3 5 1 Boot Mode Menu Boot Options Displays ...

Page 612: ...nce Manager Menu 611 CA92344 0539 04 TABLE 3 55 Display Contents of Operation Help Display Items Description Move Highlight Moves the cursor up and down Enter Select Entry Selects the items Esc Exit Returns to 3 1 Front page of Boot Manager ...

Page 613: ...3 56 Display Contents of Menu Selection Section Item Display Contents Boot Mode Select the Boot Mode UEFI and Legacy Both the boot options UEFI and Legacy are enabled Only UEFI Only the boot option UEFI is enabled Only Legacy Only the boot option Legacy is enabled Default is UEFI and Legacy Commit Changes and Exit Exit from this menu after saving the changes Discard Changes and Exit Exit from this...

Page 614: ...nce Manager Menu 613 CA92344 0539 04 TABLE 3 57 Display contents of operation help display Items Description Move Highlight Moves the cursor up and down Enter Select Entry Selects the items Esc Exit Returns to 3 1 Front page of Boot Manager ...

Page 615: ... selection is displayed TABLE 3 58 Display contents of Menu selection Item Description Go Back To Main Page 3 5 Boot maintenance Manager Menu is displayed Add Boot Option Add Boot Option Menu is displayed Delete Boot Option Delete Boot Option Menu is displayed Change Boot Order Change Boot Order Menu is displayed Set Legacy Floppy Drive Order Set Legacy Floppy Drive Order Menu is displayed Set Leg...

Page 616: ...d Boot Option Menu Add Boot Option is used to add new boot option to Boot Manager If Operating System boot loader is added and registered as boot option as shown in the following figure boot option registered in Boot Manager Menu is displayed Newly added and registered boot option is added at the tag end of Boot Manager Menu Example of addition of Test Boot Option is shown in FIGURE 3 33 Display E...

Page 617: ...Path FIGURE 3 34 Display Example of Add Boot Option Menu 1 Display of Page information File Explorer is displayed 2 Menu Selection A list of storage devices recognized by UEFI is displayed 3 Display of Operation help Description of operation key shown in TABLE 3 60 Display contents of Display of Operation help is displayed TABLE 3 60 Display contents of Display of Operation help Item Description M...

Page 618: ...vices 2 Press Enter key As shown in FIGURE 3 36 Display example of File Selection Window a list of files in the selected storage device is displayed The matter enclosed in is a directory Following is the display example when the disk installed by Windows Server 2012 is selected In case of Windows Server 2012 EFI Microsoft Boot bootx64 efi file is an Operative system loader The following files are ...

Page 619: ...UEFI Menu Operations 3 5 Boot maintenance Manager Menu 618 CA92344 0539 04 FIGURE 3 36 Display example of File Selection Window ...

Page 620: ... installed for Red Hat Enterprise Linux 6 has the following directory structure EFI redhat grub efi Operative System Boot Loader Directory structure of the disk installed for Red Hat Enterprise Linux 7 The disk installed for Red Hat Enterprise Linux 7 has the following directory structure EFI redhat shim efi Operative System Boot Loader 3 Following the directory structure bootx64 efi which is an O...

Page 621: ... window for input is displayed For details on the number of characters and types of character that can be entered see Number of Characters and Types of Characters that can be entered 6 Exit from this menu by following operations To exit from this menu after saving the changed setting select Commit Changes and Exit and press Enter key To exit from this menu without saving the changed setting select...

Page 622: ...er of Characters Types of Character Input the description 6 75 0 9 A Z a z _ Input Optional Data 0 120 0 9 A Z a z _ Remarks Input is not possible if the number of characters exceeds the restricted value Though the key exceeding the restricted value seems to be input temporarily it is ignored and is not reflected on the window Types of characters other than mentioned above cannot be entered Even i...

Page 623: ... menu 1 Page information display It is displayed as Delete Boot Option 2 Menu selection The boot option with a high priority level of automatic boot is displayed in order from top 3 Operation help menu Description of operation key is shown in TABLE 3 62 Display contents of operation help display TABLE 3 62 Display contents of operation help display Items Description Move Highlight Moves cursor in ...

Page 624: ...ace key again when delete is cancelled When Space key is pressed again changes to X 3 To exit from this menu after saving the changed setting select Commit Changes and Exit and press Enter key To exit from this menu without saving the changed setting select Discard Changes and Exit is and press Enter key 4 Confirm that the boot option is deleted normally by using the following procedure a Open the...

Page 625: ...UEFI Menu Operations 3 5 Boot maintenance Manager Menu 624 CA92344 0539 04 FIGURE 3 42 Boot Option Deletion Window 2 ...

Page 626: ...op up window is displayed when this command is executed wherein the settings of boot order can be changed As for the legacy boot option boot option with highest boot priority level of each device is displayed Legacy device consists of the following four devices Floppy Device HardDisk Device DVD CD ROM Device Network Device Change method is explained in following Change in Priority Level Change Boo...

Page 627: ...saving changes of this menu The contents displayed when the Pop up Window appears are shown in TABLE 3 65 Display Contents of Operation Help Display when Pop up Window appears TABLE 3 65 Display Contents of Operation Help Display when Pop up Window appears Item Description Move Selection Up Raise the boot priority level of boot option by 1 Move Selection Down Lower the boot priority level of boot ...

Page 628: ...44 Change Window of Priority Order Change Boot Order 1 place the cursor to boot option displayed as Change the order FIGURE 3 44 Change Window of Priority Order Change Boot Order 1 2 Press Enter key Pop up window shown in FIGURE 3 45 Change Window of Priority Order Change Boot Order 2 appears FIGURE 3 45 Change Window of Priority Order Change Boot Order 2 3 Place the cursor to boot option for whic...

Page 629: ...r key when you want to exit by saving the changes of configuration Press Esc key when you want to exit by discarding the changes of configuration FIGURE 3 46 Windows after setting of priority level is changed Change Boot Order 3 6 To exit from the menu after saving the changes select Commit Changes and Exit and then press Enter key To exit from this menu without saving the changes select Discard C...

Page 630: ...example of Set Legacy Floppy Drive Order menu 1 Page information display It is displayed as Set Legacy Floppy Drive Order 2 Menu Selection Selection menu shown in TABLE 3 66 Display contents of menu selection is displayed TABLE 3 66 Display contents of menu selection Items Description Floppy Drive N N 0 1 Switchover to change the order of Floppy boot When this item is executed pop up window is dis...

Page 631: ...e Highlight Moves cursor in up and down direction Enter Select Entry Selects item Esc Exit Returns to 3 1 Front page of Boot Manager When pop up window appears display contents are shown in TABLE 3 68 Display Contents of operation help display when pop up window appears TABLE 3 68 Display Contents of operation help display when pop up window appears Items Description Move Highlight Moves cursor in...

Page 632: ...ve Order 1 FIGURE 3 48 Change in priority level Set Legacy Floppy Drive Order 1 2 Press Enter key Pop up window appears is shown in FIGURE 3 49 Change in priority level Set Legacy Floppy Drive Order 2 FIGURE 3 49 Change in priority level Set Legacy Floppy Drive Order 2 3 Place the cursor on the boot option that is to be set in Floppy Drive N Boot option for Floppy Drive 00 is set in FIGURE 3 49 Ch...

Page 633: ...Change of priority level Set Legacy Floppy Drive Order 3 Y E DATAUSB FDU 7 03 is set in Floppy Drive 01 in which Fujitsu Virtual Floppy0 1 00 is set FIGURE 3 50 Change of priority level Set Legacy Floppy Drive Order 3 5 Set Enable Disable of the Floppy Drive N Select Disable to disable Select the boot option to enable FIGURE 3 51 Change of the priority level Set Legacy Floppy Drive Order 4 is an e...

Page 634: ...er Menu 633 CA92344 0539 04 6 To exit from this menu by saving changes in the setting select Commit Changes and Exit and press Enter key To exit from this menu without saving changes in the setting select Discard Changes and Exit and press Enter key ...

Page 635: ...TABLE 3 69 Display Contents of Menu Selection TABLE 3 69 Display Contents of Menu Selection Item Explanation HardDisk Drive N N 0 1 Following is displayed HDD information confirmed at the time of initialization after the power on Disable Displayed when Disable is selected Device for which the configuration is changed after initialization is not displayed Hence the system should be reset after the ...

Page 636: ...and down Enter Select Entry Selects the items Esc Exit Returns to 3 1 Front page of Boot Manager TABLE 3 71 Display Contents of the Operation Help Display when Pop up Window appears when pop up window appears shows the display contents of the Operation Help Display when the pop up window is appeared TABLE 3 71 Display Contents of the Operation Help Display when Pop up Window appears Item Explanati...

Page 637: ...t Legacy HardDisk Drive Order 1 place the cursor on HardDisk Drive N which wants to change the device In the FIGURE 3 53 Change of the Priority Level Set Legacy HardDisk Drive Order 1 HardDisk Drive 00 is selected FIGURE 3 53 Change of the Priority Level Set Legacy HardDisk Drive Order 1 1 Press Enter key A pop up window shown in FIGURE 3 54 Change in Priority Level Set Legacy HardDisk Drive Order...

Page 638: ...el of HDD is substituted When the boot option set in HardDisk Drive Order N is set in another HardDisk Drive Order M before setting the boot option which had been set in HardDisk Drive Order N before making changes is set in HardDisk Drive Order M In FIGURE 3 55 Change in Priority Level Set Legacy HardDisk Drive Order 3 Bus 08 Dev 00 PCIRAID Adapter is set to HardDisk Drive Order 01 in which Fujit...

Page 639: ...FIGURE 3 56 Change in Priority Level Set Legacy HardDisk Drive Order 4 6 Select Commit Changes and Exit and press Enter key to exit from the menu by saving the set changes Select Discard Changes and Exit and press Enter key to exit from the menu without saving the set changes ...

Page 640: ...egacy CD ROM Drive Order 2 Menu Selection The items indicated in TABLE 3 72 Displayed Contents of Menu Selection are displayed TABLE 3 72 Displayed Contents of Menu Selection Items Description ATAPI CDROM Drive N N 0 1 Moves to order change of DVD CD boot If the item is executed the pop up window is displayed and then the setting can be changed The change method is explained in detailed by subsequ...

Page 641: ...Esc Exit Returns to 3 1 Front page of Boot Manager The contents displayed when the Pop up Window appears are shown in TABLE 3 74 Display Contents of Operation Help Display when Pop up Window appears TABLE 3 74 Display Contents of Operation Help Display when Pop up Window appears Item Description Move Highlight Moves cursor up and down Enter Select Entry Selects item Esc Exit Returns to 3 1 Front p...

Page 642: ...evel Set Legacy CD ROM Drive Order 1 place the cursor on ATAPI CDROM Drive N for which device can be changed Select ATAPI CDROM Drive 00 on FIGURE 3 58 Change in priority level Set Legacy CD ROM Drive Order 1 FIGURE 3 58 Change in priority level Set Legacy CD ROM Drive Order 1 2 Press Enter key Pop window showed in FIGURE 3 59 Change in priority level Set Legacy CD ROM Drive Order 2 is displayed F...

Page 643: ... interchanged When the boot option set in the ATAPI CDROM Drive Order N is set in the other HardDisk Drive Order M before setting boot option set in the ATAPI CDROM Drive Order N before change is set in the ATAPI CDROM Drive Order M In the FIGURE 3 60 Change in priority level Set Legacy CD ROM Drive Order 3 Optiarc DVD RW AD 7543C1 U1is set in the ATAPI CDROM Drive Order 01wherein Fujitsu Virtual ...

Page 644: ...in priority level Set Legacy CD ROM Drive Order 4 6 When you want to exit from the menu by the saving the setting changes select Commit Changes and Exit and press Enter key When you want to exit from the menu without saving the setting changes select Discard Changes and Exit and press Enter key ...

Page 645: ...lay Displayed as Set Legacy NET Drive Order 2 Menu selection Items shown in TABLE 3 75 Display contents of menu selection are displayed TABLE 3 75 Display contents of menu selection Items Description NET Drive N N 0 1 Transited to order change of the NET boot When this item is executed pop up window is displayed Change method is explained in detail in the Change in priority order Set Legacy NET Dr...

Page 646: ... the item Esc Exit Returns to 3 1 Front page of Boot Manager TABLE 3 77 Display Content of Operation Help Display When Pop up Window Appears shows the display contents when the pop up window appears TABLE 3 77 Display Content of Operation Help Display When Pop up Window Appears Item Explanation Move Highlight Moves the cursor in up and down directions Enter Complete Entry Selects the item Esc Exit...

Page 647: ... on the screen shown in FIGURE 3 63 Change Set Legacy NET Drive Order 1 of priority level In FIGURE 3 63 Change Set Legacy NET Drive Order 1 of priority level NET Drive 00 has been selected FIGURE 3 63 Change Set Legacy NET Drive Order 1 of priority level 2 Press the Enter key A pop up window shown in FIGURE 3 64 Change of Priority Level Set Legacy NET Drive Order 2 appears FIGURE 3 64 Change of P...

Page 648: ...the window when the priority level of network port is changed When the boot option set in NET Drive N is set in another NET Drive M before setting the boot option which had been set in NET Drive N before changes is set in NET Drive M In FIGURE 3 65 Change of Priority Level Set Legacy NET Drive Order 3 IBA GE Slot 0900 v1372 is set in NET Drive 01 in which IBA GE Slot 0901 v1372 was set FIGURE 3 65...

Page 649: ...4 FIGURE 3 66 Change of Priority Level Set Legacy NET Drive Order 4 6 Select Commit Changes and Exit and press Enter key to exit from this menu by saving the set changes Select Discard Changes and Exit and press Enter key to exit from this menu without saving the set changes ...

Page 650: ...of storage devices recognized by UEFI is displayed FIGURE 3 67 Display Example of Boot From File Menu 1 Page Information Display File Explorer is displayed 2 Menu Selection Storage device list by which UEFI is recognized is displayed 3 Operation helps Display Description of operation key is shown in TABLE 3 78 Display Contents of Operation Help Display TABLE 3 78 Display Contents of Operation Help...

Page 651: ...ed from the device list window shown in TABLE 3 78 Display Contents of Operation Help Display FIGURE 3 68 Specifications of Boot File 1 2 Press Enter key As shown in FIGURE 3 69 Specifications of Boot File 2 file list of storage device appears Contents enclosed in is a directory Following figure is a display example when the disk installed by Window Server 2012 is selected FIGURE 3 69 Specificatio...

Page 652: ...r File to be booted appears as shown in FIGURE 3 70 Specifications of Boot File 3 by following the directory structure FIGURE 3 70 Specifications of Boot File 3 4 Press key or key and select Operating System Loader File to be booted 5 Press Enter key File is loading and Operating System is activated ...

Page 653: ...t does not start from Hard Disk Drive and Net Drive connected with the system This menu is for the start of the medium for maintenance When DVD CD Drive is not connected or the medium has not been inserted the following messages are displayed FIGURE 3 71 Boot From DVD CD Message It is started from the medium of DVD CD Drive again by connecting DVD CD Drive while displaying the above mentioned mess...

Page 654: ... set in this menu is the standby time of key input In the standby time of key input as shown in FIGURE 3 72 Logo Window the Logo Window appears Except Enter key if other key is input during the standby time of key input then it transited to Boot Manager Front Page Moreover if Enter key is input it immediately transit to Operating System activation process FIGURE 3 72 Logo Window Following window i...

Page 655: ... menu after the changed contents of configuration are cancelled 3 Operation Help Display Describe of operation key is shown in TABLE 3 80 Display Contents of Operation Help Display TABLE 3 80 Display Contents of Operation Help Display Item Description Move Highlight Moves cursor up and down Enter Select Entry Selects item Esc Exit Returns to 3 1 Front page of Boot Manager The contents displayed wh...

Page 656: ...4 3 6 Device Path Device path shows the physical connection of device and also shows the relation of connection from PCI Route Bridge 3 6 1 Parameter of Device Path Each parameter of displayed device path is shown in the TABLE 3 82 Parameter of Device Path ...

Page 657: ...Addr IfType Network MacAddr is an abbreviation of Mac Address If Type is an abbreviation of Interface Type 0 255 is shown with hexadecimal HD Partition Type Signature Start Size Hard Drive Partition shows the partition number Type shows Partition Type Can be omitted Type is given below GPT Abbreviation of GUID Partition Table MBR Abbreviation of Master Boot Record Signature consists of the meaning...

Page 658: ... in SB shows the device Node FIGURE 3 74 Specification of SAS disk built in SB Device Path is as follows PcieRoot 0x0 Pci 0x1C 0x0 Pci 0x0 0x0 Ctrl 0x0 Scsi 0x0 0x0 HD 1 GPT 83B59636 996C 4550 A27A EBEAA43820D0 0x800 0x32000 SAS Disk built in DU Specific method of SAS disk built in DU 0 is described as an example FIGURE 3 75 Specification of SAS Disk built in DU 0 Device path of SAS device is as f...

Page 659: ...d is inserted to PCIe of IOU is described as an example FIGURE 3 76 Specification of Disk from Fibre Card GigaLAN Specific method of GigaLAN built in IOU is described as an example FIGURE 3 77 Specification of GigaLAN Device path of GigaLAN is as follows Pcieroot 0x0 PCI 0x02 0x0 PCI 0x0 0x0 PCI 0x10 0x0 PCI 0x0 0x0 PCI 0x09 0x0 PCI 0 Card SAS Disc ...

Page 660: ...hows a screenshot of when the UEFI shell starts FIGURE 4 1 Sample screenshot of the UEFI shell immediately after it starts 4 1 1 Automatic startup file Immediately after starting the UEFI shell checks for the startup nsh file in the defined execution path If the file exists the shell executes the commands specified in the file Then it waits for command input from theconsole This situation does not...

Page 661: ...I shell Character string Meaning Matches 0 or more characters in the file name Matches exactly 1 character in the file name Character string Matches any of the characters between the brackets An example is azA Z 4 1 3 Output redirection UEFI shell command output can be redirected to a file The syntax to do so is as follows Command unicode_output_file_pathname Command a ascii_output_file_pathname C...

Page 662: ... ASCII file 2 Redirects the standard error output to a Unicode file 2 a Redirects the standard error output to an ASCII file Appends the standard output to a Unicode file a Appends the standard output to an ASCII file 1 Appends the standard output to a Unicode file 1 a Appends the standard output to an ASCII file Remarks You can redirect the standard output or standard error output to the same fil...

Page 663: ...dit Used to edit an ASCII or Unicode file in full screen mode 9 exit Exits the UEFI shell 10 help Displays the command list or command help 11 ls Displays the files and subdirectories in a directory 12 map Displays and defines a mapping 13 mkdir Creates one or more directories 14 mount Mounts a file system on a block device 15 mv Moves one or more files 16 pci Displays a PCI device or a PCI config...

Page 664: ... opt FJSVdr util sbin dr version help COMMAND ARGS 5 1 1 2 Description This is basic command to DR operation The subcommand is taken in the argument It returns when the command is completed 5 1 1 3 Options Options Meaning version Print the version number of DR command help Print the synopsis and a list of subcommands COMMAND Specify subcommand ARGS Specify arguments of subcommand 5 1 1 4 Exit stat...

Page 665: ... help add rm Device 5 1 2 2 Description This is the subcommand for hot add hot remove IOU or PCI Express card 5 1 2 3 Options Arguments Meaning Device Target device e g IOUx PCIex x represents the slot number Only one target can be specified at a time help Print the synopsis of add rm subcommand 5 1 2 4 Example e g when you hot add IOU3 opt FJSVdr util sbin dr add IOU3 ...

Page 666: ...slot power is OFF IOU is disabled online IOU is assigned to the partition and the slot power is ON IOU is enabled The meaning of the state of pcie type is as follows empty There s no PCI Express card on the slot offline PCI Express card is on the slot but the slot power is OFF PCIe is disabled online PCI Express card is on the slot and the slot power is ON PCIe is enabled 5 1 3 3 Options Arguments...

Page 667: ...e PLX Technology Inc Device 8748 rev ba 06 00 0 PCI bridge PLX Technology Inc Device 8748 rev ba 07 01 0 PCI bridge PLX Technology Inc Device 8748 rev ba 07 02 0 PCI bridge PLX Technology Inc Device 8748 rev ba 07 08 0 PCI bridge PLX Technology Inc Device 8748 rev ba 07 09 0 PCI bridge PLX Technology Inc Device 8748 rev ba 07 10 0 PCI bridge PLX Technology Inc Device 8748 rev ba 07 11 0 PCI bridge...

Page 668: ...ynopsis opt FJSVdr util sbin dr help report 5 1 5 2 Description This is the subcommand for gathering information for investigation 5 1 5 3 Options Argument Meaning help Print the synopsis of report subcommand 5 1 5 4 Example e g opt FJSVdr util sbin dr report Create report file at tmp drreport localhost 20130101 123456 tar bz2 ...

Page 669: ... deleted from a partition simply called at the deletion of SB failure time IOU hot add o Before enabling PCI devices on a hot added IOU simply called before addition of IOU o After enabling PCI devices on a hot added IOU simply called after addition of IOU o At the time that PCI devices on a hot added IOU fails to enable simply called at the addition of IOU failure time IOU hot remove o Before dis...

Page 670: ...et value Action 5 1024 Wait for the completion of a collaboration program at specified time The unit of value is the minute 0 Wait for the completion of a collaboration program unlimitedly 1 or less The value is out of assignable value Wait for the completion of a collaboration program at 5 minutes as default 1 4 The value is out of assignable value Wait for the completion of a collaboration progr...

Page 671: ...an those assigned to the collaboration programs installed by the other packages XXXXX XXXXX represents a collaboration program identifier which constructed by alpha numeral and hyphen one byte characters The recommended identifier for a collaboration program is a name from which the contents of the program can easily be inferred To avoid duplicative collaboration program name head of identifier sh...

Page 672: ... special log file Other outputs of collaboration program which executed in non verbose mode are output to system log as well as log of DR command For the log of collaborate program refer to the following 5 2 10 Output of collaboration program Configuration file of collaboration program is not indispensable If configuration file does not exist hot plug collaboration function executes collaboration ...

Page 673: ...ed to a collaboration program is shown below O Options Arguments Meaning p hot plugged device SBx IOUy Specifies the hot plugged device x and y are set to either 1 or 0 3 e hot plug eventl timing ADD_PRE ADD_POST RM_PRE RM_POST Specifies the hot plug event timing ADD_PRE before dynamic addition ADD_POST after dynamic addition RM_PRE before dynamic deletion RM_POST after dynamic deletion r result o...

Page 674: ... list is a list delimited by the comma When this list is delimited by the hyphen it means all ranges of the first and last number are included None means there is no NUMA node 2 3 4 5 7 None d PCI address Specifies the bus number device number function number PCI address of hot removed PCI device except for PCI bridge from now When hot plugged device is IOUx and hot plug event timing is RM_PRE thi...

Page 675: ...utput stdout and standard error output stderr from collaboration program output to system log But when collaboration program executes in verbose mode stdout and stderr output to a file in the following directory In this case file name becomes collaboration program name log And the output does not output to system log opt FJSVdr util var log Form of the outputs is as follows time dr util collaborat...

Page 676: ... Execute collaboration programs in ascending order of program file names Execute collaboration programs in descending order of program file names Dynamic deletion of SB Set the followig options to collaboration program p SBx e RM_PRE c x y m xxx kB n x y Execute collaboration programs in ascending order of program file names Delete CPU and memory device Success Set the followig options to collabor...

Page 677: ...ion programs in ascending order of program file names Execute collaboration programs in descending order of program file names Failure Dynamic deletion of IOU Set the followig options to collaboration program p IOUx e RM_PRE d 00 01 2 03 04 5 Execute collaboration programs in ascending order of program file names Delete PCI devices Success Set the followig options to collaboration program p IOUx e...

Page 678: ...t Confirm timeout period Timeout period is not 0 5 1024 Set default timeout period Timeout period is 0 5 1024 Execute collaboration with the setting options Confirm tiemout of the collaboration program Tiemout is 0 Wait for the completion of the collaboration program Timeout is not 0 Execute collaboration programs in ascending order of program file names Normal end A B Unexpected collaboration pro...

Page 679: ...tes in the timeout period Not complete Complete Not complete Send SIGKILL signal to the collaboration program Send SIGTERM signal to the collaboration program Check the return value of the collaboration program Return value is not 0 Confirm whether the collaboration program completes in 1 minute Return value is 0 A Abnormal end B Complete ...

Page 680: ...UEFI configuration information refer 8 1 1 Backing up and restoring UEFI configuration information in PRIMEQUEST 2000 Series Administration Manual 6 1 Sadump Configuration Menu To configure sadump select main menu to set up sadump from the Device Manager menu Configure sadump by inputting values in the main menu and submenu which is shown below The structure of menu is as follows When the PCI ROM ...

Page 681: ... of sadump environment 6 1 Sadump Configuration Menu 680 CA92344 0539 04 FIGURE 6 1 Structure of menu for sadump configuration 1 From Device Manager Menu Main menu Set up Manager Menu Dump device Manager Menu ...

Page 682: ...ment 6 1 Sadump Configuration Menu 681 CA92344 0539 04 FIGURE 6 2 Structure of menu for sadump configuration 2 From Dump device Manager Create a dump device Menu Select device Menu Select multiple devices Menu Confirmation Menu ...

Page 683: ... environment 6 1 Sadump Configuration Menu 682 CA92344 0539 04 FIGURE 6 3 Structure of menu for sadump configuration 3 From Dump device Manager Setting dump device Menu Select device Menu Select discard dump device Menu ...

Page 684: ...tion area Displays menu to operate They can be operated by Enter key etc Selected item is highlighted 3 Help display area for menu selection Displays the detailed explanation about menu selected in menu selection area 4 Help display area for operations Displays help information to operate screen FIGURE 6 4 Screen areas of sadump configuration Title Menu selection area Help display area for menu se...

Page 685: ...enu TABLE 6 1 Displayed contents of the menu selection area Item Description Set up Manager Go to sadump setup menu Dump device Manager Go to dump device maintenance menu Exit Exit this menu TABLE 6 2 Displayed contents of the help display area for operation Item Description Move Highlight Moves the cursor up or down Enter Select Entry Selects an entry Note Don t operate F2 key Esc key is displaye...

Page 686: ...ump function Enable Enable sadump Disable Disable sadump The default is Disable COMPRESS Specifies format when sadump writes to dump device Uncompress Data is not compressed RECYCLE Specifies Enable or Disable for dump device reuse When Enable is specified the oldest dump is overwritten Enable Enable RECYCLE option Disable Disable RECYCLE option The default is Enable REBOOT Specifies behavior of s...

Page 687: ...Item Description Move Highlight Moves the cursor up or down Enter Select Entry Selects an entry In the case of ENABLE COMPRESS RECYCLE selection item is shown as pop up window In the case of REBOOT you can input a value Specify a value and commit it by Enter key Note Don t operate F2 key Esc key is displayed on the screen but don t operate it ...

Page 688: ...play area Displays the number of dump devices which are already created and displays the number of dump devices which are already set up Create a dump device Go to dump device create menu Select a dump device Go to dump device setup menu Discard a dump device Go to dump device discard menu Exit Exits this menu TABLE 6 6 Displayed contents of the help display area for operation Item Description Mov...

Page 689: ...ate mode of dump device Single Create with single disk or single partition To set up for redundancy select Single and then configure multiple sadump devices Multiple Create with multiple disks Use this when system memory is large and one disk is insufficient The default is Single Disk selection Go to dump device select menu Exit Exits this menu TABLE 6 8 Displayed contents of the help display area...

Page 690: ... disk is selected the data the disk has is corrupted FIGURE 6 9 Dump device select menu TABLE 6 9 Displayed contents of menu selection area Item Description Exit Exits this menu ACPI name of disk disk partition Select disk or disk partition to create dump device Remarks Regarding to ACPI name which is used for disk or disk partition refer 5 7 Device Path To use devices of ETERNUS as dump device se...

Page 691: ...p device with selected disk or disk partition and go to dump device create menu If Exit is selected go to dump device create menu without creating dump device Note Esc key is displayed on the screen but don t operate it A dump device is initialized when it is created It takes a time to initialize depends on the size of selected disk or disk partition In some cases it takes more than several minute...

Page 692: ... 6 11 Displayed contents of the menu selection area Item Description The 1st dump device Select the 1st dump device If not selected yet only 1 is displayed The 2nd dump device Select the 2nd dump device If not selected yet only 2 is displayed The 3rd dump device Select the 3rd dump device If not selected yet only 3 is displayed Clear setting Clears all the current setting Commit Changes and Exit S...

Page 693: ...vice that is actually not present the device selection is automatically cleared Clear setting There are the following points of concern about the behavior when operating it With the second dump device or the third dump device has selected it and When you do Clear setting two times or more after it boots up a system After it executes it Clear setting the selection of the dump device might not be cl...

Page 694: ...dump disk FIGURE 6 11 Select device Menu TABLE 6 13 Displayed contents of menu selection area Item Description ACPI name of dump device ACPI name of disk partition is displayed Selected dump device is highlighted TABLE 6 14 Displayed contents of the help display area for operation Item Description Move Highlight Move the cursor up or down Enter Select Entry Select the dump device on the cursor and...

Page 695: ...d FIGURE 6 12 Select discard dump device Menu TABLE 6 15 Displayed contents of menu selection area Item Description Discard all dump device and Exit Discards all the dump devices and then exits this menu Exit Exits this menu without discarding any dump device selected ACPI name of dump device Select a dump device TABLE 6 16 Displayed contents of the help display area for operation Item Description...

Page 696: ...menu Exit Exits this menu without actually creating any dump device ACPI name of dump device ACPI name of the dump device disk is displayed Select a dump device by Space key then on the right hand of the entry is changed to X Remarks Regarding to ACPI name which is used for disk or disk partition refer 5 7 Device Path TABLE 6 18 Displayed contents of the help display area for operation Item Descri...

Page 697: ...election area Item Description Create dump device and Exit Saves the dump device configuration and exits this menu Exit Exits this menu without saving any dump device configuration Display area ACPI name of the disks selected in the Select multiple devices menu TABLE 6 20 Displayed contents of the help display area for operation Item Description Move Highlight Move the cursor up or down Enter Sele...

Page 698: ...sole Redirection Setup Window A 1 12 Setting Items of Partition Configuration Window A 1 13 Setting Items of Power Management Setup Window A 1 14 Setting Items of ASR Control Window A 1 15 Setting Items of Console Redirection Window A 1 16 Setting Items of Mode Window A 1 17 Setting Items of Add User Edit User Window A 1 18 Setting Items of Change Password Window A 1 19 Setting Items of Date Time ...

Page 699: ...maintained Unit All All Specified All and Specified can be switched and the data selected by the check boxes in Specified is maintained Source All All Specified All and Specified can be switched and the data selected by the check boxes in Specified is maintained Sort by Date Time New event first New event first Old event first Start Date Time First event First event Specified Time When Specified T...

Page 700: ...st event First event Specified Time When Specified Time is selected Start Time can be entered Switch First event and Specified time and maintain Time Data of Specified Time End Date Time Last event Last event Specified Time When Specified Time is selected End Time can be entered Switch Last event and Specified time and maintain Time Data of Specified Time side Number of events to display 100 event...

Page 701: ...e and the value that can be set of setting items of System Setup Window TABLE A 5 Setting items of System Setup Window Setting Items Initial Value Value that can be set Remarks Power Feed Mode Single Single Dual Power Restoration Policy Restore Always off Always on Restore Schedule Sync Partition Power On Delay 0 Seconds 0 9999 Seconds Altitude Altitude 1000 m Altitude 1000 m 1000 m Altitude 1500 ...

Page 702: ...ms of Power Control Window TABLE A 7 Setting Items of Power Control Window Setting items Initial value Value that can be set Remarks Power Control None Power On Power Off Power Cycle Reset NMI Force Power Off sadump Not Specified When Power Status is only Standby Power On can be selected When Power Status is only On the selections other than Power On are possible Force Power Off Delay Off Time 1 9...

Page 703: ... 1 Dec 31 Term Daily From Jan 1 To Jan 1 Weekly From Jan To Jan Monthly From Jan To Jan Daily Jan 1 Dec 31 Weekly Jan Dec Monthly Jan Dec On Time Hour 0 Min 0 Hour Specified as 24 hours Time Specified in units of 10 minutes Off Time Hour 0 Min 0 Hour Specified as 24 hours Time Specified in units of 10 minutes A 1 10 Setting Items of IPv4 Console Redirection Setup Window The following table lists t...

Page 704: ...tition Configuration Window TABLE A 12 Setting Items of Partition Configuration Window Setting items Initial value Value that can be set Remarks Partition Name None Maximum 16 characters can be entered Alphanumeric characters single byte space _ A 1 13 Setting Items of Power Management Setup Window The following table lists the initial value and the value that can be set for the setting items of P...

Page 705: ...upt assert Boot Watchdog Boot Watchdog Disable Enable Disable Timeout time seconds 6000s 1s 6000s Action when watchdog expires Continue Continue Reset Power Cycle Software Watchdog Software Watchdog Disable Enable Disable Timeout time seconds 300s 1s 6000s Action when watchdog expires Continue Continue Reset Power Cycle NMI A 1 15 Setting Items of Console Redirection Window The following table lis...

Page 706: ...arks Extended Partitioning Mode setting Disable Enable Disable When the PRIMEQUEST 2400E2 2800E2 2400E 2800E model Memory Operation Mode setting Normal Mode Performance Mode Normal Mode Partial Mode Full Mode Spare Mode Memory Mirror RAS Mode setting Mirror Keep Mode Mirror Keep Mode Capacity Keep Mode PCI Address Mode setting PCI Segment Mode PCI Bus Mode PCI Segment Mode Dynamic Reconfiguration ...

Page 707: ... Z _ However the first character must be a z A Z Password None More than 8 characters and less than 32 characters 0 9 a z A Z Special characters _ Confirm Password None More than 8 characters and less than 32 characters 0 9 a z A Z Special characters _ Privilege In case of Add User Admin In case of Edit User current privilege Admin Operator User CE Partition Operator Status In case of Add User Ena...

Page 708: ... Password Window TABLE A 18 Setting Items of Change Password Window Setting items Initial value Value that can be set Remarks Current Password None More than 8 characters and less than 32 characters 0 9 a z A Z Special characters _ Password None More than 8 characters and less than 32 characters 0 9 a z A Z Special characters _ Confirm New Password None More than 8 characters and less than 32 char...

Page 709: ...econd 24 hours format Modify the Time is Off Time is not set It can be set only when NTP is Disabled Time Zone None Select from pull down menu NTP Disable Enable Disable NTP Time Correction Mode Step Step Slew It can be set only when NTP is Enabled NTP Server 1 None In case of IPv4 0 255 0 255 0 255 0 255 In case of IPv6 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF It can be set only wh...

Page 710: ...Disable Hostname Optional None Sets hostname in FQDN format a z A Z 0 9 Hyphen Dot The First character should be alphabetic character Hyphen Dot cannot be used as the first character and the last character IP Address None 0 255 0 255 0 255 0 255 Subnet Mask None 0 255 0 255 0 255 0 255 Gateway address None 0 255 0 255 0 255 0 255 MMB 1 IP Address Interface Disable Enable Disable Hostname Optional ...

Page 711: ...le IP Address In case of PRIMEQUEST 2400E2 2800E2 2800B2 192 168 1 1 In case of PRIMEQUEST 2400E 2800E 2800B None 0 255 0 255 0 255 0 255 Subnet Mask In case of PRIMEQUEST 2400E2 2800E2 2800B2 255 255 255 0 In case of PRIMEQUEST 2400E 2800E 2800B None 0 255 0 255 0 255 0 255 Gateway address None 0 255 0 255 0 255 0 255 SMTP address None 0 255 0 255 0 255 0 255 Internal IP Address Interface Disable...

Page 712: ...FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF MMB 0 IP Address Interface Disable Enable Disable Hostname optional None Sets hostname in FQDN format a z A Z 0 9 Hyphen Dot First character must be alphabetic character Hyphen Dot cannot be used as the first character and the last character IP Address None 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF Prefix Length None 1 128 Gateway...

Page 713: ...th None 1 128 Gateway address None 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF SMTP address None 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF A 1 22 Setting Items of Management LAN Port Configuration Window The following table lists the initial value and the value that can be set for the setting items of Management LAN Port Configuration Window TABLE A 22 Setting Items of Ma...

Page 714: ...net In case of PRIMEQUEST 2400E2 2800E2 2800B2 Enable In case of PRIMEQUEST 2400E 2800E 2800B Disable Enable Disable Telnet Port 23 23 1024 65535 Telnet Timeout sec 600 second 60 9999 seconds 0 No timeout SSH SSH Disable Enable Disable SSH Port 22 22 1024 65535 SSH Timeout sec 600 seconds 60 9999 seconds 0 No timeout SNMP SNMP Agent Disable Enable Disable Agent Port 161 161 1024 65535 SNMP Trap Di...

Page 715: ...character Half width space cannot be used as the last character System contact None 0 9 a z A Z Special characters _ and half width space cannot be used as the first character Half width space cannot be used as the last character Community Community User None 0 9 a z A Z Special characters _ cannot be used as the first character IP Address Ma sk None In case of IPv4 0 255 0 255 0 255 0 255 In case...

Page 716: ...ndow Setting Item Initial Value Value that can be set Remarks Community User None In case of SNMP v1 v2 sets the SNMP Community string In case of SNMPv3 specifies the user name IP Address None In case of IPv4 0 255 0 255 0 255 0 255 In case of IPv6 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF SNMP Version 1 1 2 3 Auth None noauth auth priv Auth Type None MD5 SHA Auth passphrase None 0 9...

Page 717: ... a z A Z Special characters _ A 1 28 Setting Items of Create CSR Window The following table lists the initial value and the value that can be set for the setting items of Create CSR Window TABLE A 28 Setting Items of Create CSR Window Setting Item Initial Value Value that can be set Remarks Key length 1024 1024 2048 Country Name None ISO Country Code 2 alphabetic characters Example Japan JP USA US...

Page 718: ...6 characters 0 9 a z A Z Password None 8 characters or more less than or equal to 16 characters 0 9 a z A Z Confirm Password None 8 characters or more less than or equal to 16 characters 0 9 a z A Z Privilege In case of Add User Admin In case of Edit User Present Privilege Admin Operator User CE No Access Status Disabled Enabled Disabled Setting items Initial value Values that can be set Remarks K...

Page 719: ...fix Length None In case of IPv4 0 255 0 255 0 255 0 255 In case of IPv6 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF 0 FFFF A 1 32 Setting Items of Alarm E Mail Window The following table lists the initial value and the value that can be set for the setting items of Alarm E Mail Window TABLE A 32 Setting Items of Alarm E Mail Window Setting Item Initial value Values that can be set Remarks Ala...

Page 720: ...BLE A 33 Setting Items of Alarm E Mail Filtering Condition Window Setting item Initial value Values that can be set Remarks Severity All ON Error Warning Info Multiple selection is possible Partition All ON All Specified Multiple selection is possible When specified is selected the partition to be displayed is set ON Unit All All Specified When specified is selected the unit to be displayed is set...

Page 721: ...nfiguration Window A 2 4 Setting Items on iSCS Configuration Window A 2 4 1Setting Items on Attempt Configuration Window A 2 5 Setting Items on Memory Configuration Window A 2 6 Setting Items on USB Configuration Window A 2 7 Setting Items on Security Configuration Window A 2 1 Setting Items on LAN Remote Boot Configuration Window Following table lists the initial value and the values that can be ...

Page 722: ...Adjacent Cache Line Prefetch Enabled Disable Enable DCU Streamer Prefetcher Enabled Disable Enable DCU Ip Prefetcher Enabled Disable Enable Execute Disable Bit Enabled Disable Enable Intel Virtualization Technology 3 Enabled Disable Enable Intel R VT d 3 Disabled Disable Enable Power Technology Energy Efficient Disabled Energy Efficient Custom Enhanced SpeedStep 1 Enabled Disable Enable Displayed ...

Page 723: ...Enabled Only for PRIMEQUEST 2400E2 2800E2 2800B2 Perfmon and DFX devices 1 Disabled Disable Enable x2APIC Mode 1 Enabled Disable Enabled Only for PRIMEQUEST 2400E2 2800E2 2800B2 ACPI MSCT Enabled Disable Enabled 1 As settings of Physical Partition remain same in Extended Partitioning settings are only displayed but cannot be changed 2 This item is not displayed in Extended Partitioning 3 This item...

Page 724: ...Appendix A List of Setting Items A 2 Setting Items on UEFI 723 CA92344 0539 04 Setting item Initial value Setting value Remarks Assignment Disabled ...

Page 725: ...led Settings for PCI Express slot 0of IOU 1 Slot 19 OpROM Disabled Enabled Disabled Settings for PCI Express slot 1of IOU 1 Slot 20 OpROM Disabled Enabled Disabled Settings for PCI Express slot 2of IOU 1 Slot 21 OpROM Disabled Enabled Disabled Settings for PCI Express slot 3of IOU 1 Slot 33 OpROM DU Disabled Enabled Disabled Settings for DU 1 Slot 0 Slot 34 OpROM Disabled Enabled Disabled Settings...

Page 726: ...press slot 0 of PCI_Box 1 Slot 82 OpROM Disabled Enabled Disabled Settings for PCI Express slot 1 of PCI_Box 1 Slot 83 OpROM Disabled Enabled Disabled Settings for PCI Express slot 2 of PCI_Box 1 Slot 84 OpROM Disabled Enabled Disabled Settings for PCI Express slot 3 of PCI_Box 1 Slot 85 OpROM Disabled Enabled Disabled Settings for PCI Express slot 4 of PCI_Box 1 Slot 86 OpROM Disabled Enabled Dis...

Page 727: ...PCI_Box 3 Slot 117 OpROM Disabled Enabled Disabled Settings for PCI Express slot 4 of PCI_Box 3 Slot 118 OpROM Disabled Enabled Disabled Settings for PCI Express slot 5 of PCI_Box 3 Slot 119 OpROM Disabled Enabled Disabled Settings for PCI Express slot 6 of PCI_Box 3 Slot 120 OpROM Disabled Enabled Disabled Settings for PCI Express slot 7 of PCI_Box 3 Slot 121 OpROM Disabled Enabled Disabled Setti...

Page 728: ...figuration Window Following table lists the initial value and the values that can be set for Setting Items on iSCS Configuration window TABLE A 40 Setting Items of iSCS Configuration Window Setting Item Initial Value Setting Value Remarks iSCSI Initiator Name iSCSI Initiator Name 4 223 characters can be entered ...

Page 729: ...layed only when DHCP is Enable Initiator Subnet Mask 0 255 0 255 0 255 0 255 Displayed only when DHCP is Enable Gateway 0 255 0 255 0 255 0 255 Displayed only when DHCP is Enable Get Target info via DHCP X Displayed only when DHCP is Enable Target Name 4 223 characters can be entered The types of characters that can be entered are as follows 0 9 A Z a z _ Displayed when Get Target info via DHCP is...

Page 730: ...al Value Setting Value Remarks DIMM Speed 1 Normal Mode Performance Mode Normal Mode This item is not displayed for PRIMEQUEST 2400E2 2800E2 2800B2 Patrol scrub 1 Disabled Disabled Enabled Refresh Rate 1 Auto Auto 1x Memory Power States 1 Default Default Perfomance Mode DDR4 Command Address Parity Check and Retry 1 Enabled Disabled Enabled Only for PRIMEQUEST 2400E2 2800E2 2800B2 1 As settings of ...

Page 731: ...t cannot be changed A 2 7 Setting Items on Security Configuration Window Following table lists the initial value and the values that can be set for Setting Items on Security Configuration window In Extended Partitioning because TPM cannot be used this menu is not displayed TABLE A 44 Setting Items of Security Configuration Window Setting Item Initial Value Setting Value Remarks TPM Support Disable...

Page 732: ...ABLE A 45 Setting Items of Video Window Setting Item Initial Value Setting Value Remarks Low Bandwidth Mode Normal Normal 8bpp 8bpp B W 16bpp A 3 2 Setting Items on Keyboard Window Following table lists the initial values and the values that can be set for Setting Items on Keyboard window TABLE A 46 Setting Items of Keyboard Window Setting Item Initial Value Setting Value Remarks Host Physical Key...

Page 733: ... Items of Mouse Window Setting Item Initial Value Setting Value Remarks Mouse Mode Absolute mouse mode Absolute mouse mode Relative mouse mode Hide mouse mode A 3 4 Setting Items on Options Window Following table lists the initial values and the values that can be set for Setting Items on Options window TABLE A 48 Setting Items of Options Window Setting Item Initial Value Setting Value Remarks GUI...

Page 734: ......

Reviews: